  • Min. AWG conductor cross section, flexible
    24
  • ECLASS 5.0
    27141100
  • Maximum load current
    32 A (with 4 mm² conductor cross section)
  • Nominal current IN
    30 A
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Screw thread
    M3
  • Tightening torque, min
    0.6 Nm
  • Connection method
    Screw connection
  • Flammability rating according to UL 94
    V0
  • Nominal voltage UN
    275 V
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Length
    22 mm
  • Insulating material group
    I
  • Terminal block mounting
    When attaching the product to the mounting surface, please ensure that the housing is not damaged when tightening the center screw
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Width
    52 mm
  • Tightening torque max
    0.8 Nm
  • Conductor cross section AWG min.
    24
  • Conductor cross section AWG max.
    12
  • Height
    24 mm
  • Stripping length
    8 mm
  • Insulating material
    PA
  • Open side panel
    No
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Color
    gray
  • Nominal cross section
    4 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • Number of positions
    6
  • Connection in acc. with standard
    IEC 60947-7-1/IEC 60998
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 10.0.1
    27141120
  • ECLASS 5.1
    27141100
  • ECLASS 4.1
    27141100
  • ETIM 3.0
    EC001284
  • UNSPSC 6.01
    30211811
  • UNSPSC 20.0
    39121410
  • Degree of pollution
    3
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Conductor cross section solid min.
    0.2 mm²
  • Max. AWG conductor cross section, flexible
    12
  • 2 conductors with same cross section, solid max.
    1.5 mm²
  • 2 conductors with same cross section, solid min.
    0.2 mm²
  • UNSPSC 11
    39121410
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • 2 conductors with same cross section, stranded max.
    1.5 mm²
  • ECLASS 4.0
    27141100
  • ETIM 2.0
    EC001284
  • ETIM 4.0
    EC001284
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • Internal cylindrical gage
    A3
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Number of connections
    12
  • Potentials
    6
  • Maximum power dissipation for nominal condition
    1.02 W
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Conductor cross section flexible max.
    4 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141120
  • ECLASS 7.0
    27141106
  • ECLASS 9.0
    27141120
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.25 mm²
  • Number of levels
    1
  • Overvoltage category
    III
  • Static insulating material application in cold
    -60 °C
  • Rated surge voltage
    6 kV
  • Conductor cross section solid max.
    4 mm²
  • UNSPSC 13.2
    39121409
  • UNSPSC 18.0
    39121410
  • UNSPSC 21.0
    39121410
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • ETIM 7.0
    EC001284
  • UNSPSC 19.0
    39121410
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 6.0
    27141100
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ETIM 6.0
    EC001284
  • 2 conductors with same cross section, stranded min.
    0.2 mm²
  • UNSPSC 7.0901
    39121410
  • UNSPSC 12.01
    39121410

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

2703198 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

Compare 2703198 with other products

Min. AWG conductor cross ...

ECLASS 5.0

Maximum load current

Nominal current IN

Fire protection for rail ...

Smoke gas toxicity NFPA 1...

Screw thread

Tightening torque, min

Connection method

Flammability rating accor...

Nominal voltage UN

Relative insulation mater...

Calorimetric heat release...

Length

Insulating material group

Terminal block mounting

Surface flammability NFPA...

Fire protection for rail ...

Width

Tightening torque max

Conductor cross section A...

Conductor cross section A...

Height

Stripping length

Insulating material

Open side panel

Specific optical density ...

Fire protection for rail ...

Color

Nominal cross section

Conductor cross section f...

Number of positions

Connection in acc. with s...

Ambient temperature (stor...

ECLASS 10.0.1

ECLASS 5.1

ECLASS 4.1

ETIM 3.0

UNSPSC 6.01

UNSPSC 20.0

Degree of pollution

Temperature index of insu...

Conductor cross section s...

Max. AWG conductor cross ...

2 conductors with same cr...

2 conductors with same cr...

UNSPSC 11

Conductor cross section f...

Conductor cross section f...

2 conductors with same cr...

ECLASS 4.0

ETIM 2.0

ETIM 4.0

Two conductors with the s...

Internal cylindrical gage

Ambient temperature (actu...

Number of connections

Potentials

Maximum power dissipation...

Fire protection for rail ...

Conductor cross section f...

Ambient temperature (asse...

ECLASS 11.0

ECLASS 7.0

ECLASS 9.0

Conductor cross section f...

Conductor cross section f...

Two conductors with the s...

Two conductors with the s...

Number of levels

Overvoltage category

Static insulating materia...

Rated surge voltage

Conductor cross section s...

UNSPSC 13.2

UNSPSC 18.0

UNSPSC 21.0

Operating temperature

ETIM 7.0

UNSPSC 19.0

China RoHS

ECLASS 6.0

Two conductors with the s...

Permissible humidity (sto...

ETIM 6.0

2 conductors with same cr...

UNSPSC 7.0901

UNSPSC 12.01

Degree of protection

Ambient temperature (oper...

Max. permissible relative...

Nominal power consumption

Mains buffering time

Protective circuit/compon...

Feedback voltage resistan...

Output power

Depth

Inflammability class in a...

Climatic class

Input voltage range

Inrush current

Type of protection

Installation distance top...

Nominal input voltage ran...

Frequency range (fN)

Input fuse

Power factor (cos phi)

Connection in parallel

Residual ripple

Control deviation

Efficiency

Standard – Safety extra-l...

Discharge in air

Comments

Surge voltage load (surge...

Voltage dips

Installation distance rig...

Current consumption

Recommended breaker for i...

Nominal output current (I...

Nominal output voltage

Connection in series

Net weight

Protection class

Assembly instructions

Standard - Safety of tran...

Standard – Limitation of ...

Electromagnetic compatibi...

Contact discharge

Input

Criterion A

MTBF (IEC 61709, SN 29500...

Foot latch material

Mounting position

EMC requirements for nois...

Standard – Electronic equ...

CSA

Fast transients (burst)

Electromagnetic HF field

Output

Derating

Typical response time

Housing material

EMC requirements for nois...

Standard - Safe isolation

Criterion B

Power loss nominal load m...

Low Voltage Directive

Test field strength

Voltage

Conducted interference

Insulation voltage input/...

Standard - Electrical saf...

Frequency range

Protection against overvo...

Maximum power dissipation...

Mains variation/undervolt...

UL approvals

Electrostatic discharge

Ambient temperature (star...

Discharge current to PE

Insulation voltage output...

AC frequency range

REACh SVHC

POWER BOOST (IBoost)

Active current limitation

Signal

Width with alternative as...

Installation height

Selective Fuse Breaking (...

Insulation voltage input ...

Standard - Approval for m...

Height with alternative a...

Setting range of the outp...

Standard - Equipment safe...

Depth with alternative as...

Frequency range DC

Standard – Protection aga...

Rail applications

I/O/S

Selected product

2703198
0 in stock
2703198
Phoenix Contact

Device terminal block, for direct mounting, 6-pos.

Min. AWG conductor cross section, flexible24

ECLASS 5.027141100

Maximum load current32 A (with 4 mm² conductor c...

Nominal current IN30 A

Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3

Smoke gas toxicity NFPA 130 (SMP 800C)passed

Screw threadM3

Tightening torque, min0.6 Nm

Connection methodScrew connection

Flammability rating according to UL 94V0

Nominal voltage UN275 V

Relative insulation material temperature index (Elec., UL 746 B)130 °C

Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg

Length22 mm

Insulating material groupI

Terminal block mountingWhen attaching the product t...

Surface flammability NFPA 130 (ASTM E 162)passed

Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Width52 mm

Tightening torque max0.8 Nm

Conductor cross section AWG min.24

Conductor cross section AWG max.12

Height24 mm

Stripping length8 mm

Insulating materialPA

Open side panelNo

Specific optical density of smoke NFPA 130 (ASTM E 662)passed

Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3

Colorgray

Nominal cross section4 mm²

Conductor cross section flexible, with ferrule without plastic sleeve min.0.25 mm²

Number of positions6

Connection in acc. with standardIEC 60947-7-1/IEC 60998

Ambient temperature (storage/transport)-25 °C ... 60 °C (for a shor...

ECLASS 10.0.127141120

ECLASS 5.127141100

ECLASS 4.127141100

ETIM 3.0EC001284

UNSPSC 6.0130211811

UNSPSC 20.039121410

Degree of pollution3

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C

Conductor cross section solid min.0.2 mm²

Max. AWG conductor cross section, flexible12

2 conductors with same cross section, solid max.1.5 mm²

2 conductors with same cross section, solid min.0.2 mm²

UNSPSC 1139121410

Conductor cross section flexible min.0.2 mm²

Conductor cross section flexible, with ferrule with plastic sleeve min.0.25 mm²

2 conductors with same cross section, stranded max.1.5 mm²

ECLASS 4.027141100

ETIM 2.0EC001284

ETIM 4.0EC001284

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum1.5 mm²

Internal cylindrical gageA3

Ambient temperature (actuation)-5 °C ... 70 °C

Number of connections12

Potentials6

Maximum power dissipation for nominal condition1.02 W

Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3

Conductor cross section flexible max.4 mm²

Ambient temperature (assembly)-5 °C ... 70 °C

ECLASS 11.027141120

ECLASS 7.027141106

ECLASS 9.027141120

Conductor cross section flexible, with ferrule without plastic sleeve max.4 mm²

Conductor cross section flexible, with ferrule with plastic sleeve max.2.5 mm²

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum0.5 mm²

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum0.25 mm²

Number of levels1

Overvoltage categoryIII

Static insulating material application in cold-60 °C

Rated surge voltage6 kV

Conductor cross section solid max.4 mm²

UNSPSC 13.239121409

UNSPSC 18.039121410

UNSPSC 21.039121410

Operating temperature-60 °C ... 105 °C (max. shor...

ETIM 7.0EC001284

UNSPSC 19.039121410

China RoHSEnvironmentally Friendly Use...

ECLASS 6.027141100

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum1 mm²

Permissible humidity (storage/transport)30 % ... 70 %

ETIM 6.0EC001284

2 conductors with same cross section, stranded min.0.2 mm²

UNSPSC 7.090139121410

UNSPSC 12.0139121410

Degree of protection-

Ambient temperature (operation)-

Max. permissible relative humidity (operation)-

Nominal power consumption-

Mains buffering time-

Protective circuit/component-

Feedback voltage resistance-

Output power-

Depth-

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Climatic class-

Input voltage range-

Inrush current-

Type of protection-

Installation distance top/bottom-

Nominal input voltage range-

Frequency range (fN)-

Input fuse-

Power factor (cos phi)-

Connection in parallel-

Residual ripple-

Control deviation-

Efficiency-

Standard – Safety extra-low voltage-

Discharge in air-

Comments-

Surge voltage load (surge)-

Voltage dips-

Installation distance right/left-

Current consumption-

Recommended breaker for input protection-

Nominal output current (IN)-

Nominal output voltage-

Connection in series-

Net weight-

Protection class-

Assembly instructions-

Standard - Safety of transformers-

Standard – Limitation of mains harmonic currents-

Electromagnetic compatibility-

Contact discharge-

Input-

Criterion A-

MTBF (IEC 61709, SN 29500)-

Foot latch material-

Mounting position-

EMC requirements for noise immunity-

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

CSA-

Fast transients (burst)-

Electromagnetic HF field-

Output-

Derating-

Typical response time-

Housing material-

EMC requirements for noise emission-

Standard - Safe isolation-

Criterion B-

Power loss nominal load max.-

Low Voltage Directive-

Test field strength-

Voltage-

Conducted interference-

Insulation voltage input/output-

Standard - Electrical safety-

Frequency range-

Protection against overvoltage at the output (OVP)-

Maximum power dissipation in no-load condition-

Mains variation/undervoltage-

UL approvals-

Electrostatic discharge-

Ambient temperature (start-up type tested)-

Discharge current to PE-

Insulation voltage output / PE-

AC frequency range-

REACh SVHC-

POWER BOOST (IBoost)-

Active current limitation-

Signal-

Width with alternative assembly-

Installation height-

Selective Fuse Breaking (ISFB)-

Insulation voltage input / PE-

Standard - Approval for medical use-

Height with alternative assembly-

Setting range of the output voltage (USet)-

Standard - Equipment safety-

Depth with alternative assembly-

Frequency range DC-

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-

Rail applications-

I/O/S-

2903002
56 in stock
2903002
Phoenix Contact

Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 15 V DC/100 W

Min. AWG conductor cross section, flexible-

ECLASS 5.027049000

Maximum load current-

Nominal current IN-

Fire protection for rail vehicles (DIN EN 45545-2) R22-

Smoke gas toxicity NFPA 130 (SMP 800C)-

Screw threadM3

Tightening torque, min-

Connection methodScrew connection

Flammability rating according to UL 94-

Nominal voltage UN-

Relative insulation material temperature index (Elec., UL 746 B)-

Calorimetric heat release NFPA 130 (ASTM E 1354)-

Length-

Insulating material group-

Terminal block mounting-

Surface flammability NFPA 130 (ASTM E 162)-

Fire protection for rail vehicles (DIN EN 45545-2) R26-

Width55 mm

Tightening torque max-

Conductor cross section AWG min.24

Conductor cross section AWG max.14

Height90 mm

Stripping length8 mm

Insulating material-

Open side panel-

Specific optical density of smoke NFPA 130 (ASTM E 662)-

Fire protection for rail vehicles (DIN EN 45545-2) R23-

Color-

Nominal cross section-

Conductor cross section flexible, with ferrule without plastic sleeve min.-

Number of positions-

Connection in acc. with standard-

Ambient temperature (storage/transport)-40 °C ... 85 °C

ECLASS 10.0.127040701

ECLASS 5.127049000

ECLASS 4.127040700

ETIM 3.0EC001039

UNSPSC 6.0130211502

UNSPSC 20.039121004

Degree of pollution2

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))-

Conductor cross section solid min.0.2 mm²

Max. AWG conductor cross section, flexible-

2 conductors with same cross section, solid max.-

2 conductors with same cross section, solid min.-

UNSPSC 1139121004

Conductor cross section flexible min.0.2 mm²

Conductor cross section flexible, with ferrule with plastic sleeve min.-

2 conductors with same cross section, stranded max.-

ECLASS 4.027040700

ETIM 2.0-

ETIM 4.0EC000599

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum-

Internal cylindrical gage-

Ambient temperature (actuation)-

Number of connections-

Potentials-

Maximum power dissipation for nominal condition-

Fire protection for rail vehicles (DIN EN 45545-2) R24-

Conductor cross section flexible max.2.5 mm²

Ambient temperature (assembly)-

ECLASS 11.027040701

ECLASS 7.027049002

ECLASS 9.027040701

Conductor cross section flexible, with ferrule without plastic sleeve max.-

Conductor cross section flexible, with ferrule with plastic sleeve max.-

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum-

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum-

Number of levels-

Overvoltage category-

Static insulating material application in cold-

Rated surge voltage-

Conductor cross section solid max.2.5 mm²

UNSPSC 13.239121004

UNSPSC 18.039121004

UNSPSC 21.039121004

Operating temperature-

ETIM 7.0EC002540

UNSPSC 19.039121004

China RoHSEnvironmentally Friendly Use...

ECLASS 6.027049000

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum-

Permissible humidity (storage/transport)-

ETIM 6.0EC002540

2 conductors with same cross section, stranded min.-

UNSPSC 7.090139121004

UNSPSC 12.0139121004

Degree of protectionIP20

Ambient temperature (operation)-25 °C ... 70 °C (> 55 °C De...

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-conden...

Nominal power consumption206.3 VA

Mains buffering time> 20 ms (120 V AC)

Protective circuit/componentVaristor

Feedback voltage resistance< 25 V DC

Output power100 W

Depth84 mm

Inflammability class in acc. with UL 94 (housing / terminal blocks)V0

Climatic class3K3 (in acc. with EN 60721)

Input voltage range85 V AC ... 264 V AC

Inrush current< 30 A (typical)

Type of protectionTransient surge protection

Installation distance top/bottom30 mm / 30 mm

Nominal input voltage range100 V AC ... 240 V AC

Frequency range (fN)50 Hz ... 60 Hz 10 %

Input fuse4 A (slow-blow, internal)

Power factor (cos phi)0.54

Connection in parallelYes, for redundancy and incr...

Residual ripple< 75 mVPP (with nominal valu...

Control deviation< 1 % (change in load, stati...

Efficiencytyp. 89 % (120 V AC)

Standard – Safety extra-low voltageIEC 62368-1 (SELV) und EN 60...

Discharge in air8 kV (Test Level 3)

CommentsCriterion A

Surge voltage load (surge)EN 61000-4-5

Voltage dipsEN 61000-4-11

Installation distance right/left0 mm / 0 mm

Current consumption2.19 A (100 V AC)

Recommended breaker for input protection6 A ... 16 A (Characteristic...

Nominal output current (IN)6.67 A (-25 °C ... 55 °C)

Nominal output voltage15 V DC ±1 %

Connection in seriesyes

Net weight0.34 kg

Protection classII (in closed control cabine...

Assembly instructionsalignable: 0 mm horizontally...

Standard - Safety of transformersEN 61558-2-16

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Electromagnetic compatibilityConformance with EMC Directi...

Contact discharge6 kV (Test Level 3)

Input2 kV (Test Level 3 - symmetr...

Criterion ANormal operating behavior wi...

MTBF (IEC 61709, SN 29500)> 727000 h (40 °C)

Foot latch materialPOM (Polyoxymethylen)

Mounting positionhorizontal DIN rail NS 35, E...

EMC requirements for noise immunityEN 61000-6-1

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

CSACAN/CSA-C22.2 No. 60950-1-07

Fast transients (burst)EN 61000-4-4

Electromagnetic HF fieldEN 61000-4-3

Output1 kV (Test Level 2 - symmetr...

Derating55 °C ... 70 °C (2.5%/K)

Typical response time< 1 s

Housing materialPolycarbonate

EMC requirements for noise emissionEN 61000-6-3

Standard - Safe isolationDIN VDE 0100-410

Criterion BTemporary impairment to oper...

Power loss nominal load max.< 12 W

Low Voltage DirectiveConformance with Low Voltage...

Test field strength10 V/m

Voltage10 V (Test Level 3)

Conducted interferenceEN 61000-4-6

Insulation voltage input/output4 kV AC (type test)

Standard - Electrical safetyIEC 62368-1/VDE 0805 (SELV)

Frequency range10 kHz ... 80 MHz

Protection against overvoltage at the output (OVP)≤ 25 V DC

Maximum power dissipation in no-load condition< 0.4 W

Mains variation/undervoltageEN 61000-4-11

UL approvalsUL/C-UL listed UL 508

Electrostatic dischargeEN 61000-4-2

Ambient temperature (start-up type tested)-

Discharge current to PE-

Insulation voltage output / PE-

AC frequency range-

REACh SVHC-

POWER BOOST (IBoost)-

Active current limitation-

Signal-

Width with alternative assembly-

Installation height-

Selective Fuse Breaking (ISFB)-

Insulation voltage input / PE-

Standard - Approval for medical use-

Height with alternative assembly-

Setting range of the output voltage (USet)-

Standard - Equipment safety-

Depth with alternative assembly-

Frequency range DC-

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-

Rail applications-

I/O/S-

2320827
3 in stock
2320827
Phoenix Contact

Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology...

Min. AWG conductor cross section, flexible-

ECLASS 5.027242200

Maximum load current-

Nominal current IN-

Fire protection for rail vehicles (DIN EN 45545-2) R22-

Smoke gas toxicity NFPA 130 (SMP 800C)-

Screw threadM3

Tightening torque, min-

Connection methodScrew connection

Flammability rating according to UL 94-

Nominal voltage UN-

Relative insulation material temperature index (Elec., UL 746 B)-

Calorimetric heat release NFPA 130 (ASTM E 1354)-

Length-

Insulating material group-

Terminal block mounting-

Surface flammability NFPA 130 (ASTM E 162)-

Fire protection for rail vehicles (DIN EN 45545-2) R26-

Width96 mm

Tightening torque max-

Conductor cross section AWG min.18

Conductor cross section AWG max.10

Height130 mm

Stripping length10 mm

Insulating material-

Open side panel-

Specific optical density of smoke NFPA 130 (ASTM E 662)-

Fire protection for rail vehicles (DIN EN 45545-2) R23-

Color-

Nominal cross section-

Conductor cross section flexible, with ferrule without plastic sleeve min.-

Number of positions-

Connection in acc. with standard-

Ambient temperature (storage/transport)-40 °C ... 85 °C

ECLASS 10.0.127040701

ECLASS 5.127242200

ECLASS 4.127040700

ETIM 3.0EC001039

UNSPSC 6.0130211502

UNSPSC 20.039121004

Degree of pollution2

Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))-

Conductor cross section solid min.0.2 mm²

Max. AWG conductor cross section, flexible-

2 conductors with same cross section, solid max.-

2 conductors with same cross section, solid min.-

UNSPSC 1139121004

Conductor cross section flexible min.0.2 mm²

Conductor cross section flexible, with ferrule with plastic sleeve min.-

2 conductors with same cross section, stranded max.-

ECLASS 4.027040700

ETIM 2.0-

ETIM 4.0EC002540

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum-

Internal cylindrical gage-

Ambient temperature (actuation)-

Number of connections-

Potentials-

Maximum power dissipation for nominal condition-

Fire protection for rail vehicles (DIN EN 45545-2) R24-

Conductor cross section flexible max.4 mm²

Ambient temperature (assembly)-

ECLASS 11.027040701

ECLASS 7.027049002

ECLASS 9.027040701

Conductor cross section flexible, with ferrule without plastic sleeve max.-

Conductor cross section flexible, with ferrule with plastic sleeve max.-

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum-

Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum-

Number of levels-

Overvoltage category-

Static insulating material application in cold-

Rated surge voltage-

Conductor cross section solid max.6 mm²

UNSPSC 13.239121004

UNSPSC 18.039121004

UNSPSC 21.039121004

Operating temperature-

ETIM 7.0EC002540

UNSPSC 19.039121004

China RoHSEnvironmentally Friendly Use...

ECLASS 6.027049000

Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum-

Permissible humidity (storage/transport)-

ETIM 6.0EC002540

2 conductors with same cross section, stranded min.-

UNSPSC 7.090139121004

UNSPSC 12.0139121004

Degree of protectionIP20

Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C De...

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-conden...

Nominal power consumption1386 VA

Mains buffering timetyp. 25 ms (400 V AC)

Protective circuit/componentVaristor

Feedback voltage resistancemax. 60 V DC

Output power960 W

Depth179 mm

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Climatic class3K3 (in acc. with EN 60721)

Input voltage range3x 320 V AC ... 575 V AC

Inrush current< 20 A (typical)

Type of protectionTransient surge protection

Installation distance top/bottom-

Nominal input voltage range3x 400 V AC ... 500 V AC

Frequency range (fN)-

Input fuse-

Power factor (cos phi)-

Connection in parallelYes, for redundancy and incr...

Residual ripple< 50 mVPP (with nominal valu...

Control deviation< 1 % (change in load, stati...

Efficiency> 93 % (at 400 V AC and nomi...

Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60...

Discharge in air15 kV (Test Level 4)

CommentsCriterion A

Surge voltage load (surge)EN 61000-4-5

Voltage dips-

Installation distance right/left-

Current consumption3x 2.1 A (400 V AC)

Recommended breaker for input protection6 A ... 16 A (AC: Characteri...

Nominal output current (IN)20 A (-25 °C ... 60 °C, UOUT...

Nominal output voltage48 V DC ±1 %

Connection in seriesyes

Net weight2.5 kg

Protection classI

Assembly instructionsalignable: PN ≥50%, 5 mm hor...

Standard - Safety of transformersIEC 61558-2-17

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Electromagnetic compatibilityConformance with EMC Directi...

Contact discharge8 kV (Test Level 4)

Input2 kV (Test Level 3 - symmetr...

Criterion ANormal operating behavior wi...

MTBF (IEC 61709, SN 29500)> 890000 h (25 °C)

Foot latch material-

Mounting positionhorizontal DIN rail NS 35, E...

EMC requirements for noise immunityEN 61000-6-1

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

CSACAN/CSA-C22.2 No. 60950-1-07

Fast transients (burst)EN 61000-4-4

Electromagnetic HF fieldEN 61000-4-3

Output1 kV (Test Level 2 - symmetr...

Derating60 °C ... 70 °C (2.5%/K)

Typical response time< 1 s

Housing materialSteel sheet, zinc-plated

EMC requirements for noise emissionEN 61000-6-3

Standard - Safe isolationDIN VDE 0100-410

Criterion BTemporary impairment to oper...

Power loss nominal load max.70 W

Low Voltage DirectiveConformance with Low Voltage...

Test field strength10 V/m (Test Level 3)

Voltage10 V (Test Level 3)

Conducted interferenceEN 61000-4-6

Insulation voltage input/output4 kV AC (type test)

Standard - Electrical safetyIEC 60950-1/VDE 0805 (SELV)

Frequency range0.15 MHz ... 80 MHz

Protection against overvoltage at the output (OVP)< 60 V DC

Maximum power dissipation in no-load condition24 W

Mains variation/undervoltage-

UL approvalsUL Listed UL 508

Electrostatic dischargeEN 61000-4-2

Ambient temperature (start-up type tested)-40 °C

Discharge current to PE< 3.5 mA

Insulation voltage output / PE500 V DC (routine test)

AC frequency range45 Hz ... 65 Hz

REACh SVHCLead 7439-92-1

POWER BOOST (IBoost)22.5 A (-25 °C ... 40 °C per...

Active current limitationApprox. IBOOST = 22.5 A (for...

Signal1 kV (Test Level 2 - asymmet...

Width with alternative assembly176 mm

Installation height4000 m

Selective Fuse Breaking (ISFB)100 A (12 ms)

Insulation voltage input / PE3.5 kV AC (type test)

Standard - Approval for medical useIEC 60601-1, 2 x MOOP

Height with alternative assembly130 mm

Setting range of the output voltage (USet)30 V DC ... 56 V DC (> 48 V ...

Standard - Equipment safetyBG (design tested)

Depth with alternative assembly99 mm

Frequency range DC0 Hz

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178

Rail applicationsEN 50121-4

I/O/Sasymmetrical

About the manufacturer

Phoenix Contact

Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Relevant products

FAQ

Out if stock but available for backorder.

Device terminal block, for direct mounting, 6-pos.

What can I help you find today?

Recommended parts