2703022 Phoenix Contact Data & Networking Devices

2703022 on Power Resources International
Phoenix Contact

Part#:2703022

Manufacturer:Phoenix Contact

Category:Data & Networking Devices

Product Lifecycle:Active

Product description

Patch panel, RJ45 jack on Push-in terminal blocks, 10/100/1000 Mbps, DIN rail adapter, IP20, shield contacting with strain relief, shield current monitoring, surge protection

Product Details

  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Electromagnetic compatibility
    Conformance with EMC Directive 2014/30/EU
  • Color
    gray
  • Interface 1
    Ethernet interface, 10/100/1000Base-T(X) in accordance with IEEE 802.3
  • Depth
    86 mm
  • External cable diameter
    5.5 mm ... 6.5 mm
  • Supply voltage range
    36 V DC ... 52 V DC 10 % (via PoE)
  • Connection method
    RJ45 jack
  • Switch-on threshold
    ≥ 30 mA
  • Local diagnostics
    Yellow LED
  • Humidity
    B
  • Type of test
    Continuous shock according to EN 60068-2-27/IEC 60068-2-27
  • Height
    101.3 mm
  • Altitude
    ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
  • Electrical isolation
    FE // Ethernet
  • Signal
    ± 1 kV (Data line, asymmetrical)
  • ECLASS 11.0
    19170112
  • Net weight
    124.2 g
  • Degree of pollution
    2
  • ETIM 6.0
    EC002599
  • Conductor cross section AWG min.
    26
  • Conductor cross section flexible max.
    1.5 mm²
  • Frequency range
    0.15 MHz ... 80 MHz
  • Designation
    Shipbuilding
  • Power consumption
    270 mW (Shield current monitoring)
  • Additional text
    Please follow the special installation instructions in the documentation!
  • Width
    23.8 mm
  • EMC
    B
  • Ambient temperature (operation)
    -40 °C ... 75 °C
  • Degree of protection
    IP20 (Manufacturer's declaration)
  • Indirect discharge
    ± 6 kV
  • ECLASS 7.0
    19170112
  • Housing material
    Plastic
  • Overvoltage category
    II
  • REACh SVHC
    Lead 7439-92-1
  • Note on the connection method
    CAT5e
  • Stripping length
    8 mm
  • Serial transmission speed
    10/100/1000 Mbps
  • Current carrying capacity
    ≤ 1.5 A (≤ 60 W (PoE+))
  • Mounting type
    DIN rail mounting, stationary
  • MTTF
    3281 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
  • Transmission length
    100 m (including patch cables)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • Identification
    DNV GL
  • Standards/regulations
    DIN EN 61643-21
  • IEC test classification
    C2
  • ECLASS 9.0
    19170112
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Permissible humidity (operation)
    10 % ... 95 % (non-condensing)
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section AWG max.
    16
  • Voltage
    ≤ 10 V
  • ECLASS 6.0
    19170100
  • Conductor cross section, flexible, with ferrule, with plastic sleeve
    0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
  • Interface 2
    Ethernet interface, 10/100/1000Base-T(X) in accordance with IEEE 802.3
  • Vibration
    B
  • Test result
    10g for 16 ms, 1000 shocks in each spatial direction
  • Rated insulation voltage
    85 V DC
  • Response time
    3 s
  • Contact discharge
    ± 6 kV (Test Level 3)
  • Conductor cross section solid max.
    1.5 mm²
  • Temperature
    D
  • ETIM 7.0
    EC002599
  • Comments
    Criterion B
  • Conductor cross section flexible, with ferrule without plastic sleeve
    0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
  • ECLASS 10.0.1
    19170112
  • Pin assignment
    1:1
  • Maximum output power
    60 W
  • Precision
    ± 5 %
  • Continuous shield current
    ≤ 1.5 A
  • Certificate
    CSA 22.2 No. 60079-0 Ed. 3 / CSA 22.2 No. 60079-15:16
  • Conductor cross section solid min.
    0.2 mm²
  • Impedance
    ≤ 1 Ω
  • Maximum output current
    725 mA (PoE)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

2703022 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

Compare 2703022 with other products

Ambient temperature (stor...

Electromagnetic compatibi...

Color

Interface 1

Depth

External cable diameter

Supply voltage range

Connection method

Switch-on threshold

Local diagnostics

Humidity

Type of test

Height

Altitude

Electrical isolation

Signal

ECLASS 11.0

Net weight

Degree of pollution

ETIM 6.0

Conductor cross section A...

Conductor cross section f...

Frequency range

Designation

Power consumption

Additional text

Width

EMC

Ambient temperature (oper...

Degree of protection

Indirect discharge

ECLASS 7.0

Housing material

Overvoltage category

REACh SVHC

Note on the connection me...

Stripping length

Serial transmission speed

Current carrying capacity

Mounting type

MTTF

Transmission length

China RoHS

Identification

Standards/regulations

IEC test classification

ECLASS 9.0

Utilization restriction

Permissible humidity (ope...

Conductor cross section f...

Conductor cross section A...

Voltage

ECLASS 6.0

Conductor cross section, ...

Interface 2

Vibration

Test result

Rated insulation voltage

Response time

Contact discharge

Conductor cross section s...

Temperature

ETIM 7.0

Comments

Conductor cross section f...

ECLASS 10.0.1

Pin assignment

Maximum output power

Precision

Continuous shield current

Certificate

Conductor cross section s...

Impedance

Maximum output current

Width with alternative as...

Climatic class

AC frequency range

Mains buffering time

Nominal output voltage

Connection in parallel

Connection in series

Typical response time

Environmental protection ...

Protection class

Low Voltage Directive

Flicker

I/O/S

Installation distance top...

Current consumption

Protective circuit/compon...

Dynamic Boost (IDyn.Boost...

Selective Fuse Breaking (...

Output power

MTBF (IEC 61709, SN 29500...

Assembly instructions

EMC requirements for nois...

Standard - Safety of tran...

Standard - safety for equ...

Standard – Limitation of ...

Mains variation/undervolt...

CSA

SIQ

DNV GL noise radiation

Discharge in air

Fast transients (burst)

Conducted interference

Voltage dips

Attenuated sinusoidal osc...

Test level 4

Attenuated oscillating wa...

ECLASS 5.1

UNSPSC 21.0

Depth with alternative as...

Installation height

Frequency range (fN)

Nominal power consumption

Recommended breaker for i...

Nominal output current (I...

Protection against overvo...

Residual ripple

Insulation voltage input/...

EMC requirements for nois...

Standard – Safety extra-l...

UL approvals

Shipbuilding approval

Harmonic currents

Electrostatic discharge

Electromagnetic HF field

Surge voltage load (surge...

Voltage dip

Test level 1

Test level 5

Input, output (test level...

Signals (test level 2)

UNSPSC 20.0

Height with alternative a...

Inflammability class in a...

Discharge current to PE

Power factor (cos phi)

Static Boost (IStat.Boost...

Feedback voltage resistan...

Maximum power dissipation...

Efficiency

Insulation voltage input ...

EMC requirements, power p...

Standard - Electrical saf...

Standard - power supply d...

Conducted noise emission

DNV GL conducted interfer...

Test field strength

Output

Pulse-shape magnetic fiel...

Asymmetrical conducted di...

Test level 6

Signals (test level 1)

UNSPSC 13.2

Installation distance rig...

Ambient temperature (star...

Max. permissible relative...

Input voltage range

Nominal input voltage ran...

Inrush current

Type of protection

Setting range of the outp...

Derating

Control deviation

Power loss nominal load m...

Insulation voltage output...

Mounting position

HART FSK Physical Layer T...

Standard - Safe isolation

Rail applications

Noise emission

Input

Frequency

Number of periods

Test level 3

Input, output (test level...

Criterion B

ECLASS 5.0

UNSPSC 18.0

Power frequency magnetic ...

Damped oscillating magnet...

Test level 2

Input, output (test level...

Criterion A

Criterion C

UNSPSC 19.0

Standard – Electronic equ...

ECLASS 4.0

POWER BOOST (IBoost)

Active current limitation

ECLASS 4.1

ETIM 4.0

UNSPSC 12.01

Standard - Approval for m...

ETIM 3.0

UNSPSC 6.01

Standard - Equipment safe...

Frequency range DC

Screw thread

Standard – Protection aga...

UNSPSC 11

UNSPSC 7.0901

Selected product

2703022
0 in stock
2703022
Phoenix Contact

Patch panel, RJ45 jack on Push-in terminal blocks, 10/100/1000 Mbps, DIN rail adapter, IP20, shield ...

Ambient temperature (storage/transport)-40 °C ... 85 °C

Electromagnetic compatibilityConformance with EMC Directi...

Colorgray

Interface 1Ethernet interface, 10/100/1...

Depth86 mm

External cable diameter5.5 mm ... 6.5 mm

Supply voltage range36 V DC ... 52 V DC 10 % (v...

Connection methodRJ45 jack

Switch-on threshold≥ 30 mA

Local diagnosticsYellow LED

HumidityB

Type of testContinuous shock according t...

Height101.3 mm

Altitude≤ 5000 m (For restrictions, ...

Electrical isolationFE // Ethernet

Signal± 1 kV (Data line, asymmetri...

ECLASS 11.019170112

Net weight124.2 g

Degree of pollution2

ETIM 6.0EC002599

Conductor cross section AWG min.26

Conductor cross section flexible max.1.5 mm²

Frequency range0.15 MHz ... 80 MHz

DesignationShipbuilding

Power consumption270 mW (Shield current monit...

Additional textPlease follow the special in...

Width23.8 mm

EMCB

Ambient temperature (operation)-40 °C ... 75 °C

Degree of protectionIP20 (Manufacturer's declara...

Indirect discharge± 6 kV

ECLASS 7.019170112

Housing materialPlastic

Overvoltage categoryII

REACh SVHCLead 7439-92-1

Note on the connection methodCAT5e

Stripping length8 mm

Serial transmission speed10/100/1000 Mbps

Current carrying capacity≤ 1.5 A (≤ 60 W (PoE+))

Mounting typeDIN rail mounting, stationar...

MTTF3281 Years (SN 29500 standar...

Transmission length100 m (including patch cable...

China RoHSEnvironmentally Friendly Use...

IdentificationDNV GL

Standards/regulationsDIN EN 61643-21

IEC test classificationC2

ECLASS 9.019170112

Utilization restrictionEMC: class A product, see ma...

Permissible humidity (operation)10 % ... 95 % (non-condensin...

Conductor cross section flexible min.0.2 mm²

Conductor cross section AWG max.16

Voltage≤ 10 V

ECLASS 6.019170100

Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm² (only t...

Interface 2Ethernet interface, 10/100/1...

VibrationB

Test result10g for 16 ms, 1000 shocks i...

Rated insulation voltage85 V DC

Response time3 s

Contact discharge± 6 kV (Test Level 3)

Conductor cross section solid max.1.5 mm²

TemperatureD

ETIM 7.0EC002599

CommentsCriterion B

Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm² (only t...

ECLASS 10.0.119170112

Pin assignment1:1

Maximum output power60 W

Precision± 5 %

Continuous shield current≤ 1.5 A

CertificateCSA 22.2 No. 60079-0 Ed. 3 /...

Conductor cross section solid min.0.2 mm²

Impedance≤ 1 Ω

Maximum output current725 mA (PoE)

Width with alternative assembly-

Climatic class-

AC frequency range-

Mains buffering time-

Nominal output voltage-

Connection in parallel-

Connection in series-

Typical response time-

Environmental protection directive-

Protection class-

Low Voltage Directive-

Flicker-

I/O/S-

Installation distance top/bottom-

Current consumption-

Protective circuit/component-

Dynamic Boost (IDyn.Boost)-

Selective Fuse Breaking (ISFB)-

Output power-

MTBF (IEC 61709, SN 29500)-

Assembly instructions-

EMC requirements for noise emission-

Standard - Safety of transformers-

Standard - safety for equipment for measurement, control, and laboratory use-

Standard – Limitation of mains harmonic currents-

Mains variation/undervoltage-

CSA-

SIQ-

DNV GL noise radiation-

Discharge in air-

Fast transients (burst)-

Conducted interference-

Voltage dips-

Attenuated sinusoidal oscillations (ring wave)-

Test level 4-

Attenuated oscillating wave-

ECLASS 5.1-

UNSPSC 21.0-

Depth with alternative assembly-

Installation height-

Frequency range (fN)-

Nominal power consumption-

Recommended breaker for input protection-

Nominal output current (IN)-

Protection against overvoltage at the output (OVP)-

Residual ripple-

Insulation voltage input/output-

EMC requirements for noise immunity-

Standard – Safety extra-low voltage-

UL approvals-

Shipbuilding approval-

Harmonic currents-

Electrostatic discharge-

Electromagnetic HF field-

Surge voltage load (surge)-

Voltage dip-

Test level 1-

Test level 5-

Input, output (test level 2)-

Signals (test level 2)-

UNSPSC 20.0-

Height with alternative assembly-

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Discharge current to PE-

Power factor (cos phi)-

Static Boost (IStat.Boost)-

Feedback voltage resistance-

Maximum power dissipation in no-load condition-

Efficiency-

Insulation voltage input / PE-

EMC requirements, power plant-

Standard - Electrical safety-

Standard - power supply devices for low voltage with DC output-

Conducted noise emission-

DNV GL conducted interference-

Test field strength-

Output-

Pulse-shape magnetic field-

Asymmetrical conducted disturbance variables-

Test level 6-

Signals (test level 1)-

UNSPSC 13.2-

Installation distance right/left-

Ambient temperature (start-up type tested)-

Max. permissible relative humidity (operation)-

Input voltage range-

Nominal input voltage range-

Inrush current-

Type of protection-

Setting range of the output voltage (USet)-

Derating-

Control deviation-

Power loss nominal load max.-

Insulation voltage output / PE-

Mounting position-

HART FSK Physical Layer Test Specification Compliance-

Standard - Safe isolation-

Rail applications-

Noise emission-

Input-

Frequency-

Number of periods-

Test level 3-

Input, output (test level 3)-

Criterion B-

ECLASS 5.0-

UNSPSC 18.0-

Power frequency magnetic field-

Damped oscillating magnetic field-

Test level 2-

Input, output (test level 1)-

Criterion A-

Criterion C-

UNSPSC 19.0-

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

ECLASS 4.0-

POWER BOOST (IBoost)-

Active current limitation-

ECLASS 4.1-

ETIM 4.0-

UNSPSC 12.01-

Standard - Approval for medical use-

ETIM 3.0-

UNSPSC 6.01-

Standard - Equipment safety-

Frequency range DC-

Screw thread-

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-

UNSPSC 11-

UNSPSC 7.0901-

2904622
17 in stock
2904622
Phoenix Contact

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (sele...

Ambient temperature (storage/transport)-40 °C ... 85 °C

Electromagnetic compatibilityConformance with EMC Directi...

Color-

Interface 1-

Depth125 mm

External cable diameter-

Supply voltage range-

Connection methodPush-in connection

Switch-on threshold-

Local diagnostics-

Humidity-

Type of test-

Height130 mm

Altitude-

Electrical isolation-

Signal1 kV (Test Level 2 - asymmet...

ECLASS 11.027040701

Net weight1.1 kg

Degree of pollution2

ETIM 6.0EC002540

Conductor cross section AWG min.24

Conductor cross section flexible max.1.5 mm²

Frequency range50 Hz ... 60 Hz

Designation-

Power consumption-

Additional textTest Level 2

Width70 mm

EMC-

Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C De...

Degree of protectionIP20

Indirect discharge-

ECLASS 7.027049002

Housing material-

Overvoltage category-

REACh SVHCLead 7439-92-1

Note on the connection method-

Stripping length8 mm

Serial transmission speed-

Current carrying capacity-

Mounting type-

MTTF-

Transmission length-

China RoHSEnvironmentally Friendly Use...

Identification-

Standards/regulations-

IEC test classification-

ECLASS 9.027040701

Utilization restriction-

Permissible humidity (operation)-

Conductor cross section flexible min.0.2 mm²

Conductor cross section AWG max.16

Voltage2.5 kV

ECLASS 6.027049000

Conductor cross section, flexible, with ferrule, with plastic sleeve-

Interface 2-

Vibration-

Test result-

Rated insulation voltage-

Response time-

Contact discharge8 kV (Test Level 4)

Conductor cross section solid max.1 mm²

Temperature-

ETIM 7.0EC002540

CommentsCriterion A

Conductor cross section flexible, with ferrule without plastic sleeve-

ECLASS 10.0.127040701

Pin assignment-

Maximum output power-

Precision-

Continuous shield current-

Certificate-

Conductor cross section solid min.0.2 mm²

Impedance-

Maximum output current-

Width with alternative assembly122 mm

Climatic class3K3 (in acc. with EN 60721)

AC frequency range50 Hz ... 60 Hz -10 % ... +1...

Mains buffering timetyp. 33 ms (3x 400 V AC)

Nominal output voltage24 V DC

Connection in parallelYes, for redundancy and incr...

Connection in seriesyes

Typical response time300 ms (from SLEEP MODE)

Environmental protection directiveRoHS Directive 2011/65/EU

Protection classI

Low Voltage DirectiveConformance with Low Voltage...

FlickerEN 61000-3-3

I/O/Sasymmetrical

Installation distance top/bottom50 mm / 50 mm

Current consumption3x 0.99 A (400 V AC)

Protective circuit/componentVaristor, gas-filled surge a...

Dynamic Boost (IDyn.Boost)30 A (5 s)

Selective Fuse Breaking (ISFB)120 A (15 ms)

Output power480 W

MTBF (IEC 61709, SN 29500)> 985000 h (25 °C)

Assembly instructionsalignable: PN ≥50%, 5 mm hor...

EMC requirements for noise emissionEN 61000-6-3

Standard - Safety of transformersIEC 61558-2-16 pending

Standard - safety for equipment for measurement, control, and laboratory useIEC 61010-1

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Mains variation/undervoltageSEMI F47-0706, EN 61000-4-11

CSACAN/CSA-C22.2 No. 60950-1-07

SIQBG (type approved)

DNV GL noise radiationClass B

Discharge in air15 kV (Test Level 4)

Fast transients (burst)EN 61000-4-4

Conducted interferenceEN 61000-4-6

Voltage dipsEN 61000-4-11

Attenuated sinusoidal oscillations (ring wave)EN 61000-4-12

Test level 415 kHz 150 kHz (Test Level 4...

Attenuated oscillating waveEN 61000-4-18

ECLASS 5.127242200

UNSPSC 21.039121004

Depth with alternative assembly73 mm

Installation height≤ 5000 m (> 2000 m, observe ...

Frequency range (fN)50 Hz ... 60 Hz -10 % ... +1...

Nominal power consumption541 VA

Recommended breaker for input protection3x 4 A ... 20 A (Characteris...

Nominal output current (IN)20 A

Protection against overvoltage at the output (OVP)≤ 32 V DC

Residual ripple< 60 mVPP (with nominal valu...

Insulation voltage input/output4 kV AC (type test)

EMC requirements for noise immunityEN 61000-6-1

Standard – Safety extra-low voltageIEC 61010-1 (SELV)

UL approvalsUL Listed UL 508

Shipbuilding approvalDNV GL, PRS, BV, LR, ABS

Harmonic currentsEN 61000-3-2

Electrostatic dischargeEN 61000-4-2

Electromagnetic HF fieldEN 61000-4-3

Surge voltage load (surge)EN 61000-4-5

Voltage dip0 %

Test level 115 Hz 150 Hz (Test Level 4)

Test level 516.7 Hz 50 Hz 60 Hz (Test Le...

Input, output (test level 2)10 MHz

Signals (test level 2)100 kHz 1 MHz (Test Level 3 ...

UNSPSC 20.039121004

Height with alternative assembly130 mm

Inflammability class in acc. with UL 94 (housing / terminal blocks)V0

Discharge current to PE< 3.5 mA

Power factor (cos phi)0.94

Static Boost (IStat.Boost)25 A

Feedback voltage resistance≤ 35 V DC

Maximum power dissipation in no-load condition< 7 W (400 V AC)

Efficiencytyp. 93.9 % (400 V AC)

Insulation voltage input / PE3.5 kV AC (type test)

EMC requirements, power plantIEC 61850-3

Standard - Electrical safetyIEC 61010-2-201 (SELV)

Standard - power supply devices for low voltage with DC outputEN 61204-3

Conducted noise emissionEN 55016

DNV GL conducted interferenceClass A

Test field strength110 A/m

Output1 kV (Test Level 3 - symmetr...

Pulse-shape magnetic fieldEN 61000-4-9

Asymmetrical conducted disturbance variablesEN 61000-4-16

Test level 616.7 Hz 50 Hz 60 Hz (Test Le...

Signals (test level 1)100 kHz 1 MHz (Test Level 3 ...

UNSPSC 13.239121004

Installation distance right/left5 mm / 5 mm

Ambient temperature (start-up type tested)-40 °C

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-conden...

Input voltage range3x 400 V AC ... 500 V AC -20...

Nominal input voltage range3x 400 V AC ... 500 V AC

Inrush currenttyp. 2 A (at 25 °C)

Type of protectionTransient surge protection

Setting range of the output voltage (USet)24 V DC ... 29.5 V DC (const...

Derating> 60 °C ... 70 °C (2.5%/K)

Control deviation< 0.5 % (Static load change ...

Power loss nominal load max.< 32 W (400 V AC)

Insulation voltage output / PE0.5 kV DC (type test)

Mounting positionhorizontal DIN rail NS 35, E...

HART FSK Physical Layer Test Specification ComplianceOutput voltage UOut complian...

Standard - Safe isolationIEC 61558-2-16 pending

Rail applicationsEN 50121-3-2

Noise emissionEN 55016

Input2 kV (Test Level 4 - symmetr...

Frequency50 Hz

Number of periods0,5 / 1 / 5 / 50 / 250 perio...

Test level 31.5 kHz 15 kHz (Test Level 4...

Input, output (test level 3)100 kHz 1 MHz (Test Level 3 ...

Criterion BTemporary impairment to oper...

ECLASS 5.027242200

UNSPSC 18.039121004

Power frequency magnetic fieldEN 61000-4-8

Damped oscillating magnetic fieldEN 61000-4-10

Test level 2150 Hz 1.5 kHz (Test Level 4...

Input, output (test level 1)100 kHz 1 MHz (Test Level 3 ...

Criterion ANormal operating behavior wi...

Criterion CTemporary adverse effects on...

UNSPSC 19.039121004

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

ECLASS 4.0-

POWER BOOST (IBoost)-

Active current limitation-

ECLASS 4.1-

ETIM 4.0-

UNSPSC 12.01-

Standard - Approval for medical use-

ETIM 3.0-

UNSPSC 6.01-

Standard - Equipment safety-

Frequency range DC-

Screw thread-

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-

UNSPSC 11-

UNSPSC 7.0901-

2320827
3 in stock
2320827
Phoenix Contact

Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology...

Ambient temperature (storage/transport)-40 °C ... 85 °C

Electromagnetic compatibilityConformance with EMC Directi...

Color-

Interface 1-

Depth179 mm

External cable diameter-

Supply voltage range-

Connection methodScrew connection

Switch-on threshold-

Local diagnostics-

Humidity-

Type of test-

Height130 mm

Altitude-

Electrical isolation-

Signal1 kV (Test Level 2 - asymmet...

ECLASS 11.027040701

Net weight2.5 kg

Degree of pollution2

ETIM 6.0EC002540

Conductor cross section AWG min.18

Conductor cross section flexible max.4 mm²

Frequency range0.15 MHz ... 80 MHz

Designation-

Power consumption-

Additional text-

Width96 mm

EMC-

Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C De...

Degree of protectionIP20

Indirect discharge-

ECLASS 7.027049002

Housing materialSteel sheet, zinc-plated

Overvoltage category-

REACh SVHCLead 7439-92-1

Note on the connection method-

Stripping length10 mm

Serial transmission speed-

Current carrying capacity-

Mounting type-

MTTF-

Transmission length-

China RoHSEnvironmentally Friendly Use...

Identification-

Standards/regulations-

IEC test classification-

ECLASS 9.027040701

Utilization restriction-

Permissible humidity (operation)-

Conductor cross section flexible min.0.2 mm²

Conductor cross section AWG max.10

Voltage10 V (Test Level 3)

ECLASS 6.027049000

Conductor cross section, flexible, with ferrule, with plastic sleeve-

Interface 2-

Vibration-

Test result-

Rated insulation voltage-

Response time-

Contact discharge8 kV (Test Level 4)

Conductor cross section solid max.6 mm²

Temperature-

ETIM 7.0EC002540

CommentsCriterion A

Conductor cross section flexible, with ferrule without plastic sleeve-

ECLASS 10.0.127040701

Pin assignment-

Maximum output power-

Precision-

Continuous shield current-

Certificate-

Conductor cross section solid min.0.2 mm²

Impedance-

Maximum output current-

Width with alternative assembly176 mm

Climatic class3K3 (in acc. with EN 60721)

AC frequency range45 Hz ... 65 Hz

Mains buffering timetyp. 25 ms (400 V AC)

Nominal output voltage48 V DC ±1 %

Connection in parallelYes, for redundancy and incr...

Connection in seriesyes

Typical response time< 1 s

Environmental protection directive-

Protection classI

Low Voltage DirectiveConformance with Low Voltage...

Flicker-

I/O/Sasymmetrical

Installation distance top/bottom-

Current consumption3x 2.1 A (400 V AC)

Protective circuit/componentVaristor

Dynamic Boost (IDyn.Boost)-

Selective Fuse Breaking (ISFB)100 A (12 ms)

Output power960 W

MTBF (IEC 61709, SN 29500)> 890000 h (25 °C)

Assembly instructionsalignable: PN ≥50%, 5 mm hor...

EMC requirements for noise emissionEN 61000-6-3

Standard - Safety of transformersIEC 61558-2-17

Standard - safety for equipment for measurement, control, and laboratory use-

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Mains variation/undervoltage-

CSACAN/CSA-C22.2 No. 60950-1-07

SIQ-

DNV GL noise radiation-

Discharge in air15 kV (Test Level 4)

Fast transients (burst)EN 61000-4-4

Conducted interferenceEN 61000-4-6

Voltage dips-

Attenuated sinusoidal oscillations (ring wave)-

Test level 4-

Attenuated oscillating wave-

ECLASS 5.127242200

UNSPSC 21.039121004

Depth with alternative assembly99 mm

Installation height4000 m

Frequency range (fN)-

Nominal power consumption1386 VA

Recommended breaker for input protection6 A ... 16 A (AC: Characteri...

Nominal output current (IN)20 A (-25 °C ... 60 °C, UOUT...

Protection against overvoltage at the output (OVP)< 60 V DC

Residual ripple< 50 mVPP (with nominal valu...

Insulation voltage input/output4 kV AC (type test)

EMC requirements for noise immunityEN 61000-6-1

Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60...

UL approvalsUL Listed UL 508

Shipbuilding approval-

Harmonic currents-

Electrostatic dischargeEN 61000-4-2

Electromagnetic HF fieldEN 61000-4-3

Surge voltage load (surge)EN 61000-4-5

Voltage dip-

Test level 1-

Test level 5-

Input, output (test level 2)-

Signals (test level 2)-

UNSPSC 20.039121004

Height with alternative assembly130 mm

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Discharge current to PE< 3.5 mA

Power factor (cos phi)-

Static Boost (IStat.Boost)-

Feedback voltage resistancemax. 60 V DC

Maximum power dissipation in no-load condition24 W

Efficiency> 93 % (at 400 V AC and nomi...

Insulation voltage input / PE3.5 kV AC (type test)

EMC requirements, power plant-

Standard - Electrical safetyIEC 60950-1/VDE 0805 (SELV)

Standard - power supply devices for low voltage with DC output-

Conducted noise emission-

DNV GL conducted interference-

Test field strength10 V/m (Test Level 3)

Output1 kV (Test Level 2 - symmetr...

Pulse-shape magnetic field-

Asymmetrical conducted disturbance variables-

Test level 6-

Signals (test level 1)-

UNSPSC 13.239121004

Installation distance right/left-

Ambient temperature (start-up type tested)-40 °C

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-conden...

Input voltage range3x 320 V AC ... 575 V AC

Nominal input voltage range3x 400 V AC ... 500 V AC

Inrush current< 20 A (typical)

Type of protectionTransient surge protection

Setting range of the output voltage (USet)30 V DC ... 56 V DC (> 48 V ...

Derating60 °C ... 70 °C (2.5%/K)

Control deviation< 1 % (change in load, stati...

Power loss nominal load max.70 W

Insulation voltage output / PE500 V DC (routine test)

Mounting positionhorizontal DIN rail NS 35, E...

HART FSK Physical Layer Test Specification Compliance-

Standard - Safe isolationDIN VDE 0100-410

Rail applicationsEN 50121-4

Noise emission-

Input2 kV (Test Level 3 - symmetr...

Frequency-

Number of periods-

Test level 3-

Input, output (test level 3)-

Criterion BTemporary impairment to oper...

ECLASS 5.027242200

UNSPSC 18.039121004

Power frequency magnetic field-

Damped oscillating magnetic field-

Test level 2-

Input, output (test level 1)-

Criterion ANormal operating behavior wi...

Criterion C-

UNSPSC 19.039121004

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

ECLASS 4.027040700

POWER BOOST (IBoost)22.5 A (-25 °C ... 40 °C per...

Active current limitationApprox. IBOOST = 22.5 A (for...

ECLASS 4.127040700

ETIM 4.0EC002540

UNSPSC 12.0139121004

Standard - Approval for medical useIEC 60601-1, 2 x MOOP

ETIM 3.0EC001039

UNSPSC 6.0130211502

Standard - Equipment safetyBG (design tested)

Frequency range DC0 Hz

Screw threadM3

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178

UNSPSC 1139121004

UNSPSC 7.090139121004

About the manufacturer

Phoenix Contact

Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

About the Product Category

Devices for networking, which can be either hardware or software components, enable communication and data sharing among devices within a computer network. Their role is to create and sustain connectivity, improve the performance of the network, and safeguard data.

Data & Networking Devices

Relevant products

FAQ

Out if stock but available for backorder.

Patch panel, RJ45 jack on Push-in terminal blocks, 10/100/1000 Mbps, DIN rail adapter, IP20, shield contacting with strain relief, shield current monitoring, surge protection

What can I help you find today?

Recommended parts