2903002 Phoenix Contact AC/DC Power Supplies
Part#:2903002
Manufacturer:Phoenix Contact
Category:AC/DC Power Supplies
Product Lifecycle:Active
Get a quick Quote!
Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 15 V DC/100 W
About the manufacturer: Phoenix Contact is one of the manufacturers that offers AC/DC Power Supplies that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2903002 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 90 mm
- Degree of protection IP20
- Ambient temperature (operation) -25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal power consumption 206.3 VA
- Mains buffering time > 20 ms (120Â VÂ AC)
- Protective circuit/component Varistor
- Feedback voltage resistance < 25 VÂ DC
- Output power 100 W
- Depth 84 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Climatic class 3K3 (in acc. with EN 60721)
- Input voltage range 85 VÂ AC ... 264 VÂ AC
- Inrush current < 30 A (typical)
- Type of protection Transient surge protection
- Width 55 mm
- Installation distance top/bottom 30 mm / 30 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Nominal input voltage range 100 VÂ AC ... 240 VÂ AC
- Frequency range (fN) 50 Hz ... 60 Hz 10 %
- Input fuse 4 A (slow-blow, internal)
- Power factor (cos phi) 0.54
- Connection in parallel Yes, for redundancy and increased capacity
- Residual ripple < 75 mVPP (with nominal values)
- Control deviation < 1 % (change in load, static 10 % ... 90 %)
- Efficiency typ. 89 % (120Â VÂ AC)
- Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
- Discharge in air 8 kV (Test Level 3)
- Comments Criterion A
- Surge voltage load (surge) ENÂ 61000-4-5
- Voltage dips ENÂ 61000-4-11
- ECLASS 10.0.1 27040701
- ETIM 6.0 EC002540
- UNSPSC 11 39121004
- UNSPSC 19.0 39121004
- Installation distance right/left 0 mm / 0 mm
- Degree of pollution 2
- Current consumption 2.19 A (100Â VÂ AC)
- Recommended breaker for input protection 6 A ... 16 A (Characteristics B, C, D, K)
- Nominal output current (IN) 6.67 A (-25 °C ... 55 °C)
- Nominal output voltage 15 V DC ±1 %
- Connection in series yes
- Net weight 0.34 kg
- Protection class II (in closed control cabinet)
- Assembly instructions alignable: 0Â mm horizontally, 30Â mm vertically
- Conductor cross section AWG min. 24
- Screw thread M3
- Standard - Safety of transformers ENÂ 61558-2-16
- Standard – Limitation of mains harmonic currents EN 61000-3-2
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Contact discharge 6 kV (Test Level 3)
- Input 2 kV (Test Level 3 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 4.0 27040700
- ECLASS 5.1 27049000
- ETIM 3.0 EC001039
- UNSPSC 12.01 39121004
- UNSPSC 21.0 39121004
- MTBF (IEC 61709, SN 29500) > 727000 h (40 °C)
- Foot latch material POM (Polyoxymethylen)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section flexible max. 2.5 mm²
- EMC requirements for noise immunity ENÂ 61000-6-1
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- CSA CAN/CSA-C22.2 No. 60950-1-07
- Fast transients (burst) ENÂ 61000-4-4
- Electromagnetic HF field ENÂ 61000-4-3
- Output 1 kV (Test Level 2 - symmetrical)
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 6.0 27049000
- ECLASS 7.0 27049002
- UNSPSC 7.0901 39121004
- UNSPSC 18.0 39121004
- ECLASS 5.0 27049000
- ECLASS 9.0 27040701
- ETIM 7.0 EC002540
- UNSPSC 20.0 39121004
- Derating 55 °C ... 70 °C (2.5%/K)
- Typical response time < 1 s
- Housing material Polycarbonate
- EMC requirements for noise emission ENÂ 61000-6-3
- Standard - Safe isolation DINÂ VDEÂ 0100-410
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 4.1 27040700
- ETIM 4.0 EC000599
- Power loss nominal load max. < 12 W
- Conductor cross section solid min. 0.2 mm²
- Stripping length 8 mm
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Test field strength 10 V/m
- Voltage 10 V (Test Level 3)
- Conducted interference ENÂ 61000-4-6
- UNSPSC 6.01 30211502
- Insulation voltage input/output 4 kV AC (type test)
- Connection method Screw connection
- Conductor cross section flexible min. 0.2 mm²
- Standard - Electrical safety IECÂ 62368-1/VDEÂ 0805 (SELV)
- Frequency range 10 kHz ... 80 MHz
- Protection against overvoltage at the output (OVP) ≤ 25 V DC
- Maximum power dissipation in no-load condition < 0.4 W
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section AWG max. 14
- Mains variation/undervoltage ENÂ 61000-4-11
- UL approvals UL/C-UL listed UL 508
- Electrostatic discharge EN 61000-4-2
- ECLASS 11.0 27040701
- UNSPSC 13.2 39121004
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?