1552379 Phoenix Contact Electrical Wires & Cables


Part#:1552379
Manufacturer:Phoenix Contact
Category:Electrical Wires & Cables
Product Lifecycle:Active
Product description
Bus system flush-type plug, PROFINET, 4-pos., M12, shielded, D-coded, rear/screw mounting with M16 thread, with 5 m bus cable, 2 x 2 x 0.34 mm²
Product Details
- Standards/regulations according to IEC 61076-2-101
- Thread type M16 x 1.5
- Coding D-coded
- Degree of pollution 3
- Contact surface material Ni/Au
- Cable type PROFINET
- External sheath, color green RAL 6018
- Flammability rating according to UL 94 V0
- ECLASS 10.0.1 27440102
- ECLASS 5.0 27143400
- Cable cross section 0.34
- Degree of protection IP65/IP67
- Contact material CuZn
- Outer sheath, material PVC
- Standards/specifications according to IEC 61076-2-101
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 5.1 27143400
- Fixed cable length 5
- Mounting type Rear wall/screw mounting
- Number of positions 4
- Contact resistance with connected conductor ≤ 3 mΩ
- Smallest bending radius, fixed installation 20 mm
- ECLASS 4.0 27140800
- ECLASS 7.0 27440103
- ETIM 4.0 EC000830
- Overvoltage category II
- Rated surge voltage 2.5 kV AC
- Voltage 250 V
- Smallest bending radius, movable installation 46 mm
- ECLASS 11.0 27440102
- ETIM 6.0 EC002061
- UNSPSC 12.01 31251501
- UNSPSC 21.0 39121413
- Ambient temperature (operation) -25 ... -85 (Plug / socket)
- AWG signal line 22
- Current 4 A
- Cable gland material Nickel-plated brass
- Connection method Bus line
- REACh SVHC Lead 7439-92-1
- Safety note WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
- ECLASS 4.1 27140800
- UNSPSC 13.2 39121413
- ECLASS 6.0 27279200
- UNSPSC 11 31251501
- ECLASS 9.0 27440102
- UNSPSC 19.0 39121413
- UNSPSC 20.0 39121413
- ETIM 3.0 EC002061
- UNSPSC 7.0901 31251501
- UNSPSC 6.01 31251501
- UNSPSC 18.0 39121413
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
1552379 Phoenix Contact
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes

Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
Compare 1552379 with other products
Standards/regulations
Thread type
Coding
Degree of pollution
Contact surface material
Cable type
External sheath, color
Flammability rating according to UL 94
ECLASS 10.0.1
ECLASS 5.0
Cable cross section
Degree of protection
Contact material
Outer sheath, material
Standards/specifications
China RoHS
ECLASS 5.1
Fixed cable length
Mounting type
Number of positions
Contact resistance with connected conductor
Smallest bending radius, fixed installation
ECLASS 4.0
ECLASS 7.0
ETIM 4.0
Overvoltage category
Rated surge voltage
Voltage
Smallest bending radius, movable installation
ECLASS 11.0
ETIM 6.0
UNSPSC 12.01
UNSPSC 21.0
Ambient temperature (operation)
AWG signal line
Current
Cable gland material
Connection method
REACh SVHC
Safety note
ECLASS 4.1
UNSPSC 13.2
ECLASS 6.0
UNSPSC 11
ECLASS 9.0
UNSPSC 19.0
UNSPSC 20.0
ETIM 3.0
UNSPSC 7.0901
UNSPSC 6.01
UNSPSC 18.0
Height
Ambient temperature (start-up type tested)
Degree of pollution
Discharge current to PE
Mains buffering time
Protective circuit/component
Connection in parallel
Output power
MTBF (IEC 61709, SN 29500)
Insulation voltage output / PE
Conductor cross section solid min.
Conductor cross section AWG max.
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
UL approvals
Contact discharge
Test field strength
Input
Criterion B
ECLASS 11.0
ECLASS 4.0
Depth
Degree of protection
Max. permissible relative humidity (operation)
Input voltage range
AC frequency range
REACh SVHC
Recommended breaker for input protection
POWER BOOST (IBoost)
Connection in series
Active current limitation
Typical response time
Housing material
Assembly instructions
Connection method
Standard - Safety of transformers
Standard – Limitation of mains harmonic currents
Electromagnetic HF field
Signal
Criterion A
ECLASS 4.1
ETIM 4.0
UNSPSC 12.01
Width with alternative assembly
Ambient temperature (operation)
Installation height
Nominal power consumption
Nominal output current (IN)
Selective Fuse Breaking (ISFB)
Protection against overvoltage at the output (OVP)
Net weight
Insulation voltage input / PE
Mounting position
Conductor cross section flexible min.
Stripping length
EMC requirements for noise emission
Standard – Safety extra-low voltage
Standard - Approval for medical use
CSA
Electrostatic discharge
Low Voltage Directive
Fast transients (burst)
Output
Voltage
China RoHS
ECLASS 5.0
ETIM 3.0
ETIM 6.0
UNSPSC 6.01
UNSPSC 20.0
Width
Height with alternative assembly
Climatic class
Current consumption
Type of protection
Setting range of the output voltage (USet)
Feedback voltage resistance
Residual ripple
Power loss nominal load max.
Insulation voltage input/output
Protection class
Conductor cross section AWG min.
EMC requirements for noise immunity
Standard - Electrical safety
Standard - Equipment safety
Standard - Safe isolation
Electromagnetic compatibility
Frequency range
Surge voltage load (surge)
Conducted interference
ECLASS 6.0
ETIM 7.0
UNSPSC 21.0
Depth with alternative assembly
Ambient temperature (storage/transport)
Nominal input voltage range
Frequency range DC
Inrush current
Nominal output voltage
Derating
Control deviation
Maximum power dissipation in no-load condition
Efficiency
Conductor cross section solid max.
Conductor cross section flexible max.
Screw thread
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment
Rail applications
Discharge in air
Comments
I/O/S
ECLASS 10.0.1
ECLASS 5.1
ECLASS 9.0
UNSPSC 11
UNSPSC 18.0
ECLASS 7.0
UNSPSC 7.0901
UNSPSC 13.2
UNSPSC 19.0
Height
Degree of protection
Ambient temperature (operation)
Max. permissible relative humidity (operation)
Nominal power consumption
Mains buffering time
Protective circuit/component
Feedback voltage resistance
Output power
Depth
Inflammability class in acc. with UL 94 (housing / terminal blocks)
Climatic class
Input voltage range
Inrush current
Type of protection
Width
Installation distance top/bottom
Ambient temperature (storage/transport)
Nominal input voltage range
Frequency range (fN)
Input fuse
Power factor (cos phi)
Connection in parallel
Residual ripple
Control deviation
Efficiency
Standard – Safety extra-low voltage
Discharge in air
Comments
Surge voltage load (surge)
Voltage dips
ECLASS 10.0.1
ETIM 6.0
UNSPSC 11
UNSPSC 19.0
Installation distance right/left
Degree of pollution
Current consumption
Recommended breaker for input protection
Nominal output current (IN)
Nominal output voltage
Connection in series
Net weight
Protection class
Assembly instructions
Conductor cross section AWG min.
Screw thread
Standard - Safety of transformers
Standard – Limitation of mains harmonic currents
Electromagnetic compatibility
Contact discharge
Input
Criterion A
ECLASS 4.0
ECLASS 5.1
ETIM 3.0
UNSPSC 12.01
UNSPSC 21.0
MTBF (IEC 61709, SN 29500)
Foot latch material
Mounting position
Conductor cross section flexible max.
EMC requirements for noise immunity
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
CSA
Fast transients (burst)
Electromagnetic HF field
Output
China RoHS
ECLASS 6.0
ECLASS 7.0
UNSPSC 7.0901
UNSPSC 18.0
ECLASS 5.0
ECLASS 9.0
ETIM 7.0
UNSPSC 20.0
Derating
Typical response time
Housing material
EMC requirements for noise emission
Standard - Safe isolation
Criterion B
ECLASS 4.1
ETIM 4.0
Power loss nominal load max.
Conductor cross section solid min.
Stripping length
Low Voltage Directive
Test field strength
Voltage
Conducted interference
UNSPSC 6.01
Insulation voltage input/output
Connection method
Conductor cross section flexible min.
Standard - Electrical safety
Frequency range
Protection against overvoltage at the output (OVP)
Maximum power dissipation in no-load condition
Conductor cross section solid max.
Conductor cross section AWG max.
Mains variation/undervoltage
UL approvals
Electrostatic discharge
ECLASS 11.0
UNSPSC 13.2
Selected product

1552379
Phoenix Contact
Bus system flush-type plug, PROFINET, 4-pos., M12, shielded, D-coded, rear/screw mounting with M16 t...
Standards/regulationsaccording to IEC 61076-2-101
Thread typeM16 x 1.5
CodingD-coded
Degree of pollution3
Contact surface materialNi/Au
Cable typePROFINET
External sheath, colorgreen RAL 6018
Flammability rating according to UL 94V0
ECLASS 10.0.127440102
ECLASS 5.027143400
Cable cross section0.34
Degree of protectionIP65/IP67
Contact materialCuZn
Outer sheath, materialPVC
Standards/specificationsaccording to IEC 61076-2-101
China RoHSEnvironmentally Friendly Use Period = 50 years
ECLASS 5.127143400
Fixed cable length5
Mounting typeRear wall/screw mounting
Number of positions4
Contact resistance with connected conductor≤ 3 mΩ
Smallest bending radius, fixed installation20 mm
ECLASS 4.027140800
ECLASS 7.027440103
ETIM 4.0EC000830
Overvoltage categoryII
Rated surge voltage2.5 kV AC
Voltage250 V
Smallest bending radius, movable installation46 mm
ECLASS 11.027440102
ETIM 6.0EC002061
UNSPSC 12.0131251501
UNSPSC 21.039121413
Ambient temperature (operation)-25 ... -85 (Plug / socket)
AWG signal line22
Current4 A
Cable gland materialNickel-plated brass
Connection methodBus line
REACh SVHCLead 7439-92-1
Safety noteWARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
ECLASS 4.127140800
UNSPSC 13.239121413
ECLASS 6.027279200
UNSPSC 1131251501
ECLASS 9.027440102
UNSPSC 19.039121413
UNSPSC 20.039121413
ETIM 3.0EC002061
UNSPSC 7.090131251501
UNSPSC 6.0131251501
UNSPSC 18.039121413
Height-
Ambient temperature (start-up type tested)-
Degree of pollution-
Discharge current to PE-
Mains buffering time-
Protective circuit/component-
Connection in parallel-
Output power-
MTBF (IEC 61709, SN 29500)-
Insulation voltage output / PE-
Conductor cross section solid min.-
Conductor cross section AWG max.-
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-
UL approvals-
Contact discharge-
Test field strength-
Input-
Criterion B-
ECLASS 11.0-
ECLASS 4.0-
Depth-
Degree of protection-
Max. permissible relative humidity (operation)-
Input voltage range-
AC frequency range-
REACh SVHC-
Recommended breaker for input protection-
POWER BOOST (IBoost)-
Connection in series-
Active current limitation-
Typical response time-
Housing material-
Assembly instructions-
Connection method-
Standard - Safety of transformers-
Standard – Limitation of mains harmonic currents-
Electromagnetic HF field-
Signal-
Criterion A-
ECLASS 4.1-
ETIM 4.0-
UNSPSC 12.01-
Width with alternative assembly-
Ambient temperature (operation)-
Installation height-
Nominal power consumption-
Nominal output current (IN)-
Selective Fuse Breaking (ISFB)-
Protection against overvoltage at the output (OVP)-
Net weight-
Insulation voltage input / PE-
Mounting position-
Conductor cross section flexible min.-
Stripping length-
EMC requirements for noise emission-
Standard – Safety extra-low voltage-
Standard - Approval for medical use-
CSA-
Electrostatic discharge-
Low Voltage Directive-
Fast transients (burst)-
Output-
Voltage-
China RoHS-
ECLASS 5.0-
ETIM 3.0-
ETIM 6.0-
UNSPSC 6.01-
UNSPSC 20.0-
Width-
Height with alternative assembly-
Climatic class-
Current consumption-
Type of protection-
Setting range of the output voltage (USet)-
Feedback voltage resistance-
Residual ripple-
Power loss nominal load max.-
Insulation voltage input/output-
Protection class-
Conductor cross section AWG min.-
EMC requirements for noise immunity-
Standard - Electrical safety-
Standard - Equipment safety-
Standard - Safe isolation-
Electromagnetic compatibility-
Frequency range-
Surge voltage load (surge)-
Conducted interference-
ECLASS 6.0-
ETIM 7.0-
UNSPSC 21.0-
Depth with alternative assembly-
Ambient temperature (storage/transport)-
Nominal input voltage range-
Frequency range DC-
Inrush current-
Nominal output voltage-
Derating-
Control deviation-
Maximum power dissipation in no-load condition-
Efficiency-
Conductor cross section solid max.-
Conductor cross section flexible max.-
Screw thread-
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-
Rail applications-
Discharge in air-
Comments-
I/O/S-
ECLASS 10.0.1-
ECLASS 5.1-
ECLASS 9.0-
UNSPSC 11-
UNSPSC 18.0-
ECLASS 7.0-
UNSPSC 7.0901-
UNSPSC 13.2-
UNSPSC 19.0-
Height-
Degree of protection-
Ambient temperature (operation)-
Max. permissible relative humidity (operation)-
Nominal power consumption-
Mains buffering time-
Protective circuit/component-
Feedback voltage resistance-
Output power-
Depth-
Inflammability class in acc. with UL 94 (housing / terminal blocks)-
Climatic class-
Input voltage range-
Inrush current-
Type of protection-
Width-
Installation distance top/bottom-
Ambient temperature (storage/transport)-
Nominal input voltage range-
Frequency range (fN)-
Input fuse-
Power factor (cos phi)-
Connection in parallel-
Residual ripple-
Control deviation-
Efficiency-
Standard – Safety extra-low voltage-
Discharge in air-
Comments-
Surge voltage load (surge)-
Voltage dips-
ECLASS 10.0.1-
ETIM 6.0-
UNSPSC 11-
UNSPSC 19.0-
Installation distance right/left-
Degree of pollution-
Current consumption-
Recommended breaker for input protection-
Nominal output current (IN)-
Nominal output voltage-
Connection in series-
Net weight-
Protection class-
Assembly instructions-
Conductor cross section AWG min.-
Screw thread-
Standard - Safety of transformers-
Standard – Limitation of mains harmonic currents-
Electromagnetic compatibility-
Contact discharge-
Input-
Criterion A-
ECLASS 4.0-
ECLASS 5.1-
ETIM 3.0-
UNSPSC 12.01-
UNSPSC 21.0-
MTBF (IEC 61709, SN 29500)-
Foot latch material-
Mounting position-
Conductor cross section flexible max.-
EMC requirements for noise immunity-
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-
CSA-
Fast transients (burst)-
Electromagnetic HF field-
Output-
China RoHS-
ECLASS 6.0-
ECLASS 7.0-
UNSPSC 7.0901-
UNSPSC 18.0-
ECLASS 5.0-
ECLASS 9.0-
ETIM 7.0-
UNSPSC 20.0-
Derating-
Typical response time-
Housing material-
EMC requirements for noise emission-
Standard - Safe isolation-
Criterion B-
ECLASS 4.1-
ETIM 4.0-
Power loss nominal load max.-
Conductor cross section solid min.-
Stripping length-
Low Voltage Directive-
Test field strength-
Voltage-
Conducted interference-
UNSPSC 6.01-
Insulation voltage input/output-
Connection method-
Conductor cross section flexible min.-
Standard - Electrical safety-
Frequency range-
Protection against overvoltage at the output (OVP)-
Maximum power dissipation in no-load condition-
Conductor cross section solid max.-
Conductor cross section AWG max.-
Mains variation/undervoltage-
UL approvals-
Electrostatic discharge-
ECLASS 11.0-
UNSPSC 13.2-
About the manufacturer

Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
About the Product Category
Electrical wires and cables serve to establish electrical connections between switches, outlets, appliances, and more in homes, businesses, and industrial environments.

Relevant products
FAQ
Out if stock but available for backorder.
Bus system flush-type plug, PROFINET, 4-pos., M12, shielded, D-coded, rear/screw mounting with M16 thread, with 5 m bus cable, 2 x 2 x 0.34 mm²
What can I help you find today?