Sensor/actuator flush-type plug, 5-pos., M12-SPEEDCON, A-coded, rear/screw mounting with Pg9 thread, with straight solder connection, design with 12 mm long solder pins
Product Details
- Rated current at 40°C 4 A
- Coding A - standard
- Insertion/withdrawal cycles > 100
- Contact surface material Au
- Standards/specifications M12 connector IEC 61076-2-101
- ECLASS 5.1 27143400
- ECLASS 9.0 27440102
- ETIM 6.0 EC002061
- UNSPSC 13.2 39121413
- Length of the solder pin 12 mm
- Rated surge voltage 1.5 kV
- Standards/regulations M12 connector IEC 61076-2-101
- Connection method Solder pins
- Contact material CuZn
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 4.1 27140800
- ETIM 3.0 EC002061
- UNSPSC 7.0901 31261501
- UNSPSC 18.0 39121413
- Note The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences ari
- Insulation resistance ≥ 100 MΩ
- Status display No
- Torque 3 Nm ... 4 Nm (Installation-side)
- Sealing material NBR
- ECLASS 5.0 27143400
- ECLASS 4.0 27140800
- UNSPSC 12.01 31261501
- Degree of protection IP67 (When plugged in)
- Rated voltage 60 V
- Degree of pollution 3
- Mounting type Rear mounting Pg9 With flat nut
- REACh SVHC Lead 7439-92-1
- Contact carrier material PA 6.6
- ECLASS 11.0 27440102
- ECLASS 7.0 27440103
- UNSPSC 6.01 31261501
- UNSPSC 11 31261501
- Ambient temperature (operation) -40 °C ... 85 °C (cable, fixed installation)
- Number of positions 5
- Overvoltage category II
- Thread type Pg9
- Flammability rating according to UL 94 V0
- Material, knurls Zinc die-cast, nickel-plated
- ECLASS 10.0.1 27440102
- ECLASS 6.0 27279200
- UNSPSC 20.0 39121413
- UNSPSC 19.0 39121413
- ETIM 4.0 EC002062
- UNSPSC 21.0 39121413
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
1552311 Phoenix Contact
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes

Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
Compare 1552311 with other products
Rated current at 40°C
Coding
Insertion/withdrawal cycles
Contact surface material
Standards/specifications
ECLASS 5.1
ECLASS 9.0
ETIM 6.0
UNSPSC 13.2
Length of the solder pin
Rated surge voltage
Standards/regulations
Connection method
Contact material
China RoHS
ECLASS 4.1
ETIM 3.0
UNSPSC 7.0901
UNSPSC 18.0
Note
Insulation resistance
Status display
Torque
Sealing material
ECLASS 5.0
ECLASS 4.0
UNSPSC 12.01
Degree of protection
Rated voltage
Degree of pollution
Mounting type
REACh SVHC
Contact carrier material
ECLASS 11.0
ECLASS 7.0
UNSPSC 6.01
UNSPSC 11
Ambient temperature (operation)
Number of positions
Overvoltage category
Thread type
Flammability rating according to UL 94
Material, knurls
ECLASS 10.0.1
ECLASS 6.0
UNSPSC 20.0
UNSPSC 19.0
ETIM 4.0
UNSPSC 21.0
Height
Ambient temperature (start-up type tested)
Degree of pollution
Discharge current to PE
Mains buffering time
Protective circuit/component
Connection in parallel
Output power
MTBF (IEC 61709, SN 29500)
Insulation voltage output / PE
Conductor cross section solid min.
Conductor cross section AWG max.
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
UL approvals
Contact discharge
Test field strength
Input
Criterion B
ECLASS 11.0
ECLASS 4.0
Depth
Degree of protection
Max. permissible relative humidity (operation)
Input voltage range
AC frequency range
REACh SVHC
Recommended breaker for input protection
POWER BOOST (IBoost)
Connection in series
Active current limitation
Typical response time
Housing material
Assembly instructions
Connection method
Standard - Safety of transformers
Standard – Limitation of mains harmonic currents
Electromagnetic HF field
Signal
Criterion A
ECLASS 4.1
ETIM 4.0
UNSPSC 12.01
Width with alternative assembly
Ambient temperature (operation)
Installation height
Nominal power consumption
Nominal output current (IN)
Selective Fuse Breaking (ISFB)
Protection against overvoltage at the output (OVP)
Net weight
Insulation voltage input / PE
Mounting position
Conductor cross section flexible min.
Stripping length
EMC requirements for noise emission
Standard – Safety extra-low voltage
Standard - Approval for medical use
CSA
Electrostatic discharge
Low Voltage Directive
Fast transients (burst)
Output
Voltage
China RoHS
ECLASS 5.0
ETIM 3.0
ETIM 6.0
UNSPSC 6.01
UNSPSC 20.0
Width
Height with alternative assembly
Climatic class
Current consumption
Type of protection
Setting range of the output voltage (USet)
Feedback voltage resistance
Residual ripple
Power loss nominal load max.
Insulation voltage input/output
Protection class
Conductor cross section AWG min.
EMC requirements for noise immunity
Standard - Electrical safety
Standard - Equipment safety
Standard - Safe isolation
Electromagnetic compatibility
Frequency range
Surge voltage load (surge)
Conducted interference
ECLASS 6.0
ETIM 7.0
UNSPSC 21.0
Depth with alternative assembly
Ambient temperature (storage/transport)
Nominal input voltage range
Frequency range DC
Inrush current
Nominal output voltage
Derating
Control deviation
Maximum power dissipation in no-load condition
Efficiency
Conductor cross section solid max.
Conductor cross section flexible max.
Screw thread
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment
Rail applications
Discharge in air
Comments
I/O/S
ECLASS 10.0.1
ECLASS 5.1
ECLASS 9.0
UNSPSC 11
UNSPSC 18.0
ECLASS 7.0
UNSPSC 7.0901
UNSPSC 13.2
UNSPSC 19.0
Height
Degree of protection
Ambient temperature (operation)
Max. permissible relative humidity (operation)
Nominal power consumption
Mains buffering time
Protective circuit/component
Feedback voltage resistance
Output power
Depth
Inflammability class in acc. with UL 94 (housing / terminal blocks)
Climatic class
Input voltage range
Inrush current
Type of protection
Width
Installation distance top/bottom
Ambient temperature (storage/transport)
Nominal input voltage range
Frequency range (fN)
Input fuse
Power factor (cos phi)
Connection in parallel
Residual ripple
Control deviation
Efficiency
Standard – Safety extra-low voltage
Discharge in air
Comments
Surge voltage load (surge)
Voltage dips
ECLASS 10.0.1
ETIM 6.0
UNSPSC 11
UNSPSC 19.0
Installation distance right/left
Degree of pollution
Current consumption
Recommended breaker for input protection
Nominal output current (IN)
Nominal output voltage
Connection in series
Net weight
Protection class
Assembly instructions
Conductor cross section AWG min.
Screw thread
Standard - Safety of transformers
Standard – Limitation of mains harmonic currents
Electromagnetic compatibility
Contact discharge
Input
Criterion A
ECLASS 4.0
ECLASS 5.1
ETIM 3.0
UNSPSC 12.01
UNSPSC 21.0
MTBF (IEC 61709, SN 29500)
Foot latch material
Mounting position
Conductor cross section flexible max.
EMC requirements for noise immunity
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations
CSA
Fast transients (burst)
Electromagnetic HF field
Output
China RoHS
ECLASS 6.0
ECLASS 7.0
UNSPSC 7.0901
UNSPSC 18.0
ECLASS 5.0
ECLASS 9.0
ETIM 7.0
UNSPSC 20.0
Derating
Typical response time
Housing material
EMC requirements for noise emission
Standard - Safe isolation
Criterion B
ECLASS 4.1
ETIM 4.0
Power loss nominal load max.
Conductor cross section solid min.
Stripping length
Low Voltage Directive
Test field strength
Voltage
Conducted interference
UNSPSC 6.01
Insulation voltage input/output
Connection method
Conductor cross section flexible min.
Standard - Electrical safety
Frequency range
Protection against overvoltage at the output (OVP)
Maximum power dissipation in no-load condition
Conductor cross section solid max.
Conductor cross section AWG max.
Mains variation/undervoltage
UL approvals
Electrostatic discharge
ECLASS 11.0
UNSPSC 13.2
Selected product

1552311
Phoenix Contact
Sensor/actuator flush-type plug, 5-pos., M12-SPEEDCON, A-coded, rear/screw mounting with Pg9 thread,...
Rated current at 40°C4 A
CodingA - standard
Insertion/withdrawal cycles> 100
Contact surface materialAu
Standards/specificationsM12 connector IEC 61076-2-101
ECLASS 5.127143400
ECLASS 9.027440102
ETIM 6.0EC002061
UNSPSC 13.239121413
Length of the solder pin12 mm
Rated surge voltage1.5 kV
Standards/regulationsM12 connector IEC 61076-2-101
Connection methodSolder pins
Contact materialCuZn
China RoHSEnvironmentally Friendly Use Period = 50 years
ECLASS 4.127140800
ETIM 3.0EC002061
UNSPSC 7.090131261501
UNSPSC 18.039121413
NoteThe electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences ari
Insulation resistance≥ 100 MΩ
Status displayNo
Torque3 Nm ... 4 Nm (Installation-side)
Sealing materialNBR
ECLASS 5.027143400
ECLASS 4.027140800
UNSPSC 12.0131261501
Degree of protectionIP67 (When plugged in)
Rated voltage60 V
Degree of pollution3
Mounting typeRear mounting Pg9 With flat nut
REACh SVHCLead 7439-92-1
Contact carrier materialPA 6.6
ECLASS 11.027440102
ECLASS 7.027440103
UNSPSC 6.0131261501
UNSPSC 1131261501
Ambient temperature (operation)-40 °C ... 85 °C (cable, fixed installation)
Number of positions5
Overvoltage categoryII
Thread typePg9
Flammability rating according to UL 94V0
Material, knurlsZinc die-cast, nickel-plated
ECLASS 10.0.127440102
ECLASS 6.027279200
UNSPSC 20.039121413
UNSPSC 19.039121413
ETIM 4.0EC002062
UNSPSC 21.039121413
Height-
Ambient temperature (start-up type tested)-
Degree of pollution-
Discharge current to PE-
Mains buffering time-
Protective circuit/component-
Connection in parallel-
Output power-
MTBF (IEC 61709, SN 29500)-
Insulation voltage output / PE-
Conductor cross section solid min.-
Conductor cross section AWG max.-
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-
UL approvals-
Contact discharge-
Test field strength-
Input-
Criterion B-
ECLASS 11.0-
ECLASS 4.0-
Depth-
Degree of protection-
Max. permissible relative humidity (operation)-
Input voltage range-
AC frequency range-
REACh SVHC-
Recommended breaker for input protection-
POWER BOOST (IBoost)-
Connection in series-
Active current limitation-
Typical response time-
Housing material-
Assembly instructions-
Connection method-
Standard - Safety of transformers-
Standard – Limitation of mains harmonic currents-
Electromagnetic HF field-
Signal-
Criterion A-
ECLASS 4.1-
ETIM 4.0-
UNSPSC 12.01-
Width with alternative assembly-
Ambient temperature (operation)-
Installation height-
Nominal power consumption-
Nominal output current (IN)-
Selective Fuse Breaking (ISFB)-
Protection against overvoltage at the output (OVP)-
Net weight-
Insulation voltage input / PE-
Mounting position-
Conductor cross section flexible min.-
Stripping length-
EMC requirements for noise emission-
Standard – Safety extra-low voltage-
Standard - Approval for medical use-
CSA-
Electrostatic discharge-
Low Voltage Directive-
Fast transients (burst)-
Output-
Voltage-
China RoHS-
ECLASS 5.0-
ETIM 3.0-
ETIM 6.0-
UNSPSC 6.01-
UNSPSC 20.0-
Width-
Height with alternative assembly-
Climatic class-
Current consumption-
Type of protection-
Setting range of the output voltage (USet)-
Feedback voltage resistance-
Residual ripple-
Power loss nominal load max.-
Insulation voltage input/output-
Protection class-
Conductor cross section AWG min.-
EMC requirements for noise immunity-
Standard - Electrical safety-
Standard - Equipment safety-
Standard - Safe isolation-
Electromagnetic compatibility-
Frequency range-
Surge voltage load (surge)-
Conducted interference-
ECLASS 6.0-
ETIM 7.0-
UNSPSC 21.0-
Depth with alternative assembly-
Ambient temperature (storage/transport)-
Nominal input voltage range-
Frequency range DC-
Inrush current-
Nominal output voltage-
Derating-
Control deviation-
Maximum power dissipation in no-load condition-
Efficiency-
Conductor cross section solid max.-
Conductor cross section flexible max.-
Screw thread-
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-
Rail applications-
Discharge in air-
Comments-
I/O/S-
ECLASS 10.0.1-
ECLASS 5.1-
ECLASS 9.0-
UNSPSC 11-
UNSPSC 18.0-
ECLASS 7.0-
UNSPSC 7.0901-
UNSPSC 13.2-
UNSPSC 19.0-
Height-
Degree of protection-
Ambient temperature (operation)-
Max. permissible relative humidity (operation)-
Nominal power consumption-
Mains buffering time-
Protective circuit/component-
Feedback voltage resistance-
Output power-
Depth-
Inflammability class in acc. with UL 94 (housing / terminal blocks)-
Climatic class-
Input voltage range-
Inrush current-
Type of protection-
Width-
Installation distance top/bottom-
Ambient temperature (storage/transport)-
Nominal input voltage range-
Frequency range (fN)-
Input fuse-
Power factor (cos phi)-
Connection in parallel-
Residual ripple-
Control deviation-
Efficiency-
Standard – Safety extra-low voltage-
Discharge in air-
Comments-
Surge voltage load (surge)-
Voltage dips-
ECLASS 10.0.1-
ETIM 6.0-
UNSPSC 11-
UNSPSC 19.0-
Installation distance right/left-
Degree of pollution-
Current consumption-
Recommended breaker for input protection-
Nominal output current (IN)-
Nominal output voltage-
Connection in series-
Net weight-
Protection class-
Assembly instructions-
Conductor cross section AWG min.-
Screw thread-
Standard - Safety of transformers-
Standard – Limitation of mains harmonic currents-
Electromagnetic compatibility-
Contact discharge-
Input-
Criterion A-
ECLASS 4.0-
ECLASS 5.1-
ETIM 3.0-
UNSPSC 12.01-
UNSPSC 21.0-
MTBF (IEC 61709, SN 29500)-
Foot latch material-
Mounting position-
Conductor cross section flexible max.-
EMC requirements for noise immunity-
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-
CSA-
Fast transients (burst)-
Electromagnetic HF field-
Output-
China RoHS-
ECLASS 6.0-
ECLASS 7.0-
UNSPSC 7.0901-
UNSPSC 18.0-
ECLASS 5.0-
ECLASS 9.0-
ETIM 7.0-
UNSPSC 20.0-
Derating-
Typical response time-
Housing material-
EMC requirements for noise emission-
Standard - Safe isolation-
Criterion B-
ECLASS 4.1-
ETIM 4.0-
Power loss nominal load max.-
Conductor cross section solid min.-
Stripping length-
Low Voltage Directive-
Test field strength-
Voltage-
Conducted interference-
UNSPSC 6.01-
Insulation voltage input/output-
Connection method-
Conductor cross section flexible min.-
Standard - Electrical safety-
Frequency range-
Protection against overvoltage at the output (OVP)-
Maximum power dissipation in no-load condition-
Conductor cross section solid max.-
Conductor cross section AWG max.-
Mains variation/undervoltage-
UL approvals-
Electrostatic discharge-
ECLASS 11.0-
UNSPSC 13.2-
About the manufacturer

Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
About the Product Category
Electrical wires and cables serve to establish electrical connections between switches, outlets, appliances, and more in homes, businesses, and industrial environments.

Relevant products
FAQ
Out if stock but available for backorder.
Sensor/actuator flush-type plug, 5-pos., M12-SPEEDCON, A-coded, rear/screw mounting with Pg9 thread, with straight solder connection, design with 12 mm long solder pins
What can I help you find today?