1552117 Phoenix Contact Electrical Wires & Cables

1552117 on Power Resources International
Phoenix Contact

Part#:1552117

Manufacturer:Phoenix Contact

Category:Electrical Wires & Cables

Product Lifecycle:Active

Product description

Sensor/actuator cable, 4-position, Variable cable type, shielded, Plug angled M8, on Socket straight M8, cable length: Free input (0.2 ... 40.0 m)

Product Details

  • Length of cable
    Free input (0.2 ... 40.0 m)
  • Insulation resistance
    ≥ 100 GΩ*km (at 20 °C)
  • Overvoltage category
    II
  • Contact carrier material
    TPU GF
  • Cable type (abbreviation)
    PUR
  • Conductor structure signal line
    32x 0.10 mm
  • Overall twist
    4 wires, twisted
  • Sealing material
    NBR
  • Status display
    No
  • Number of positions
    4
  • Flammability rating according to UL 94
    HB
  • Note
    This item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.
  • Cable abbreviation
    LiF9YC11Y
  • UL AWM style
    20549
  • Thickness, insulation
    ≥ 0.21 mm (Core insulation)
  • Smallest bending radius, movable installation
    48 mm
  • Number of bending cycles
    10000000
  • Acceleration
    10 m/s²
  • Outer sheath, material
    PUR
  • Test voltage, cable
    ≥ 3000 V
  • Other resistance
    Highly resistant to acids, alkaline solutions and solvents
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 10.0.1
    27060311
  • ECLASS 5.0
    27061800
  • ECLASS 6.0
    27279200
  • UNSPSC 11
    31251501
  • UNSPSC 20.0
    31251501
  • Rated current at 40°C
    4 A
  • ECLASS 9.0
    27060311
  • ETIM 6.0
    EC001855
  • UNSPSC 7.0901
    31251501
  • Ambient temperature (operation)
    -40 °C ... 80 °C (cable, fixed installation)
  • Rated voltage
    48 V AC
  • Protective circuit/component
    unwired
  • Insertion/withdrawal cycles
    ≥ 100
  • Cable type
    PUR halogen-free black
  • AWG signal line
    24
  • Wire colors
    brown, white, blue, black
  • Shielding
    Braided copper wires
  • External sheath, color
    black-gray RAL 7021
  • Traversing path
    10 m
  • Traversing rate
    3 m/s
  • Conductor resistance
    max. 78 Ω/km (at 20 °C)
  • Flame resistance
    in accordance with UL 758/1581 FT2
  • ECLASS 4.0
    27060300
  • ETIM 7.0
    EC001855
  • UNSPSC 12.01
    31251501
  • Contact material
    CuSn
  • Degree of protection
    IP65
  • Coding
    A - standard
  • Conductor cross section
    4x 0.25 mm² (Signal line)
  • Core diameter including insulation
    1.17 mm ±0.02 mm (Signal line)
  • Optical shield covering
    80 %
  • Bending radius
    48 mm
  • Cable weight
    31 kg/km
  • Conductor material
    Bare Cu litz wires
  • Special properties
    Flexible cable conduit capable
  • ECLASS 4.1
    27060300
  • ECLASS 7.0
    27279218
  • ETIM 4.0
    EC001855
  • UNSPSC 19.0
    31251501
  • UNSPSC 21.0
    31251501
  • Degree of pollution
    3
  • Contact surface material
    Ni/Au
  • Material of grip body
    TPU, hardly inflammable, self-extinguishing
  • Material, knurls
    Zinc die-cast, nickel-plated
  • Material conductor insulation
    PP
  • Nominal voltage, cable
    ≤ 300 V
  • Halogen-free
    in accordance with DIN VDE 0472 part 815
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.1
    27061800
  • ETIM 3.0
    EC001855
  • UNSPSC 13.2
    31251501
  • External cable diameter D
    4.7 mm ±0.15 mm
  • Smallest bending radius, fixed installation
    24 mm
  • UNSPSC 6.01
    31251501
  • ECLASS 11.0
    27060311
  • Resistance to oil
    in accordance with DIN EN 60811-2-1

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

1552117 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

Compare 1552117 with other products

Length of cable

Insulation resistance

Overvoltage category

Contact carrier material

Cable type (abbreviation)

Conductor structure signal line

Overall twist

Sealing material

Status display

Number of positions

Flammability rating according to UL 94

Note

Cable abbreviation

UL AWM style

Thickness, insulation

Smallest bending radius, movable installation

Number of bending cycles

Acceleration

Outer sheath, material

Test voltage, cable

Other resistance

REACh SVHC

ECLASS 10.0.1

ECLASS 5.0

ECLASS 6.0

UNSPSC 11

UNSPSC 20.0

Rated current at 40°C

ECLASS 9.0

ETIM 6.0

UNSPSC 7.0901

Ambient temperature (operation)

Rated voltage

Protective circuit/component

Insertion/withdrawal cycles

Cable type

AWG signal line

Wire colors

Shielding

External sheath, color

Traversing path

Traversing rate

Conductor resistance

Flame resistance

ECLASS 4.0

ETIM 7.0

UNSPSC 12.01

Contact material

Degree of protection

Coding

Conductor cross section

Core diameter including insulation

Optical shield covering

Bending radius

Cable weight

Conductor material

Special properties

ECLASS 4.1

ECLASS 7.0

ETIM 4.0

UNSPSC 19.0

UNSPSC 21.0

Degree of pollution

Contact surface material

Material of grip body

Material, knurls

Material conductor insulation

Nominal voltage, cable

Halogen-free

China RoHS

ECLASS 5.1

ETIM 3.0

UNSPSC 13.2

External cable diameter D

Smallest bending radius, fixed installation

UNSPSC 6.01

ECLASS 11.0

Resistance to oil

Height

Ambient temperature (start-up type tested)

Degree of pollution

Discharge current to PE

Mains buffering time

Protective circuit/component

Connection in parallel

Output power

MTBF (IEC 61709, SN 29500)

Insulation voltage output / PE

Conductor cross section solid min.

Conductor cross section AWG max.

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations

UL approvals

Contact discharge

Test field strength

Input

Criterion B

ECLASS 11.0

ECLASS 4.0

Depth

Degree of protection

Max. permissible relative humidity (operation)

Input voltage range

AC frequency range

REACh SVHC

Recommended breaker for input protection

POWER BOOST (IBoost)

Connection in series

Active current limitation

Typical response time

Housing material

Assembly instructions

Connection method

Standard - Safety of transformers

Standard – Limitation of mains harmonic currents

Electromagnetic HF field

Signal

Criterion A

ECLASS 4.1

ETIM 4.0

UNSPSC 12.01

Width with alternative assembly

Ambient temperature (operation)

Installation height

Nominal power consumption

Nominal output current (IN)

Selective Fuse Breaking (ISFB)

Protection against overvoltage at the output (OVP)

Net weight

Insulation voltage input / PE

Mounting position

Conductor cross section flexible min.

Stripping length

EMC requirements for noise emission

Standard – Safety extra-low voltage

Standard - Approval for medical use

CSA

Electrostatic discharge

Low Voltage Directive

Fast transients (burst)

Output

Voltage

China RoHS

ECLASS 5.0

ETIM 3.0

ETIM 6.0

UNSPSC 6.01

UNSPSC 20.0

Width

Height with alternative assembly

Climatic class

Current consumption

Type of protection

Setting range of the output voltage (USet)

Feedback voltage resistance

Residual ripple

Power loss nominal load max.

Insulation voltage input/output

Protection class

Conductor cross section AWG min.

EMC requirements for noise immunity

Standard - Electrical safety

Standard - Equipment safety

Standard - Safe isolation

Electromagnetic compatibility

Frequency range

Surge voltage load (surge)

Conducted interference

ECLASS 6.0

ETIM 7.0

UNSPSC 21.0

Depth with alternative assembly

Ambient temperature (storage/transport)

Nominal input voltage range

Frequency range DC

Inrush current

Nominal output voltage

Derating

Control deviation

Maximum power dissipation in no-load condition

Efficiency

Conductor cross section solid max.

Conductor cross section flexible max.

Screw thread

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment

Rail applications

Discharge in air

Comments

I/O/S

ECLASS 10.0.1

ECLASS 5.1

ECLASS 9.0

UNSPSC 11

UNSPSC 18.0

ECLASS 7.0

UNSPSC 7.0901

UNSPSC 13.2

UNSPSC 19.0

Height

Degree of protection

Ambient temperature (operation)

Max. permissible relative humidity (operation)

Nominal power consumption

Mains buffering time

Protective circuit/component

Feedback voltage resistance

Output power

Depth

Inflammability class in acc. with UL 94 (housing / terminal blocks)

Climatic class

Input voltage range

Inrush current

Type of protection

Width

Installation distance top/bottom

Ambient temperature (storage/transport)

Nominal input voltage range

Frequency range (fN)

Input fuse

Power factor (cos phi)

Connection in parallel

Residual ripple

Control deviation

Efficiency

Standard – Safety extra-low voltage

Discharge in air

Comments

Surge voltage load (surge)

Voltage dips

ECLASS 10.0.1

ETIM 6.0

UNSPSC 11

UNSPSC 19.0

Installation distance right/left

Degree of pollution

Current consumption

Recommended breaker for input protection

Nominal output current (IN)

Nominal output voltage

Connection in series

Net weight

Protection class

Assembly instructions

Conductor cross section AWG min.

Screw thread

Standard - Safety of transformers

Standard – Limitation of mains harmonic currents

Electromagnetic compatibility

Contact discharge

Input

Criterion A

ECLASS 4.0

ECLASS 5.1

ETIM 3.0

UNSPSC 12.01

UNSPSC 21.0

MTBF (IEC 61709, SN 29500)

Foot latch material

Mounting position

Conductor cross section flexible max.

EMC requirements for noise immunity

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations

CSA

Fast transients (burst)

Electromagnetic HF field

Output

China RoHS

ECLASS 6.0

ECLASS 7.0

UNSPSC 7.0901

UNSPSC 18.0

ECLASS 5.0

ECLASS 9.0

ETIM 7.0

UNSPSC 20.0

Derating

Typical response time

Housing material

EMC requirements for noise emission

Standard - Safe isolation

Criterion B

ECLASS 4.1

ETIM 4.0

Power loss nominal load max.

Conductor cross section solid min.

Stripping length

Low Voltage Directive

Test field strength

Voltage

Conducted interference

UNSPSC 6.01

Insulation voltage input/output

Connection method

Conductor cross section flexible min.

Standard - Electrical safety

Frequency range

Protection against overvoltage at the output (OVP)

Maximum power dissipation in no-load condition

Conductor cross section solid max.

Conductor cross section AWG max.

Mains variation/undervoltage

UL approvals

Electrostatic discharge

ECLASS 11.0

UNSPSC 13.2

Selected product

1552117
0 in stock
1552117
Phoenix Contact

Sensor/actuator cable, 4-position, Variable cable type, shielded, Plug angled M8, on Socket straight...

Length of cableFree input (0.2 ... 40.0 m)

Insulation resistance≥ 100 GΩ*km (at 20 °C)

Overvoltage categoryII

Contact carrier materialTPU GF

Cable type (abbreviation)PUR

Conductor structure signal line32x 0.10 mm

Overall twist4 wires, twisted

Sealing materialNBR

Status displayNo

Number of positions4

Flammability rating according to UL 94HB

NoteThis item is a sensor/actuator cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.

Cable abbreviationLiF9YC11Y

UL AWM style20549

Thickness, insulation≥ 0.21 mm (Core insulation)

Smallest bending radius, movable installation48 mm

Number of bending cycles10000000

Acceleration10 m/s²

Outer sheath, materialPUR

Test voltage, cable≥ 3000 V

Other resistanceHighly resistant to acids, alkaline solutions and solvents

REACh SVHCLead 7439-92-1

ECLASS 10.0.127060311

ECLASS 5.027061800

ECLASS 6.027279200

UNSPSC 1131251501

UNSPSC 20.031251501

Rated current at 40°C4 A

ECLASS 9.027060311

ETIM 6.0EC001855

UNSPSC 7.090131251501

Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)

Rated voltage48 V AC

Protective circuit/componentunwired

Insertion/withdrawal cycles≥ 100

Cable typePUR halogen-free black

AWG signal line24

Wire colorsbrown, white, blue, black

ShieldingBraided copper wires

External sheath, colorblack-gray RAL 7021

Traversing path10 m

Traversing rate3 m/s

Conductor resistancemax. 78 Ω/km (at 20 °C)

Flame resistancein accordance with UL 758/1581 FT2

ECLASS 4.027060300

ETIM 7.0EC001855

UNSPSC 12.0131251501

Contact materialCuSn

Degree of protectionIP65

CodingA - standard

Conductor cross section4x 0.25 mm² (Signal line)

Core diameter including insulation1.17 mm ±0.02 mm (Signal line)

Optical shield covering80 %

Bending radius48 mm

Cable weight31 kg/km

Conductor materialBare Cu litz wires

Special propertiesFlexible cable conduit capable

ECLASS 4.127060300

ECLASS 7.027279218

ETIM 4.0EC001855

UNSPSC 19.031251501

UNSPSC 21.031251501

Degree of pollution3

Contact surface materialNi/Au

Material of grip bodyTPU, hardly inflammable, self-extinguishing

Material, knurlsZinc die-cast, nickel-plated

Material conductor insulationPP

Nominal voltage, cable≤ 300 V

Halogen-freein accordance with DIN VDE 0472 part 815

China RoHSEnvironmentally Friendly Use Period = 50 years

ECLASS 5.127061800

ETIM 3.0EC001855

UNSPSC 13.231251501

External cable diameter D4.7 mm ±0.15 mm

Smallest bending radius, fixed installation24 mm

UNSPSC 6.0131251501

ECLASS 11.027060311

Resistance to oilin accordance with DIN EN 60811-2-1

Height-

Ambient temperature (start-up type tested)-

Degree of pollution-

Discharge current to PE-

Mains buffering time-

Protective circuit/component-

Connection in parallel-

Output power-

MTBF (IEC 61709, SN 29500)-

Insulation voltage output / PE-

Conductor cross section solid min.-

Conductor cross section AWG max.-

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

UL approvals-

Contact discharge-

Test field strength-

Input-

Criterion B-

ECLASS 11.0-

ECLASS 4.0-

Depth-

Degree of protection-

Max. permissible relative humidity (operation)-

Input voltage range-

AC frequency range-

REACh SVHC-

Recommended breaker for input protection-

POWER BOOST (IBoost)-

Connection in series-

Active current limitation-

Typical response time-

Housing material-

Assembly instructions-

Connection method-

Standard - Safety of transformers-

Standard – Limitation of mains harmonic currents-

Electromagnetic HF field-

Signal-

Criterion A-

ECLASS 4.1-

ETIM 4.0-

UNSPSC 12.01-

Width with alternative assembly-

Ambient temperature (operation)-

Installation height-

Nominal power consumption-

Nominal output current (IN)-

Selective Fuse Breaking (ISFB)-

Protection against overvoltage at the output (OVP)-

Net weight-

Insulation voltage input / PE-

Mounting position-

Conductor cross section flexible min.-

Stripping length-

EMC requirements for noise emission-

Standard – Safety extra-low voltage-

Standard - Approval for medical use-

CSA-

Electrostatic discharge-

Low Voltage Directive-

Fast transients (burst)-

Output-

Voltage-

China RoHS-

ECLASS 5.0-

ETIM 3.0-

ETIM 6.0-

UNSPSC 6.01-

UNSPSC 20.0-

Width-

Height with alternative assembly-

Climatic class-

Current consumption-

Type of protection-

Setting range of the output voltage (USet)-

Feedback voltage resistance-

Residual ripple-

Power loss nominal load max.-

Insulation voltage input/output-

Protection class-

Conductor cross section AWG min.-

EMC requirements for noise immunity-

Standard - Electrical safety-

Standard - Equipment safety-

Standard - Safe isolation-

Electromagnetic compatibility-

Frequency range-

Surge voltage load (surge)-

Conducted interference-

ECLASS 6.0-

ETIM 7.0-

UNSPSC 21.0-

Depth with alternative assembly-

Ambient temperature (storage/transport)-

Nominal input voltage range-

Frequency range DC-

Inrush current-

Nominal output voltage-

Derating-

Control deviation-

Maximum power dissipation in no-load condition-

Efficiency-

Conductor cross section solid max.-

Conductor cross section flexible max.-

Screw thread-

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-

Rail applications-

Discharge in air-

Comments-

I/O/S-

ECLASS 10.0.1-

ECLASS 5.1-

ECLASS 9.0-

UNSPSC 11-

UNSPSC 18.0-

ECLASS 7.0-

UNSPSC 7.0901-

UNSPSC 13.2-

UNSPSC 19.0-

Height-

Degree of protection-

Ambient temperature (operation)-

Max. permissible relative humidity (operation)-

Nominal power consumption-

Mains buffering time-

Protective circuit/component-

Feedback voltage resistance-

Output power-

Depth-

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Climatic class-

Input voltage range-

Inrush current-

Type of protection-

Width-

Installation distance top/bottom-

Ambient temperature (storage/transport)-

Nominal input voltage range-

Frequency range (fN)-

Input fuse-

Power factor (cos phi)-

Connection in parallel-

Residual ripple-

Control deviation-

Efficiency-

Standard – Safety extra-low voltage-

Discharge in air-

Comments-

Surge voltage load (surge)-

Voltage dips-

ECLASS 10.0.1-

ETIM 6.0-

UNSPSC 11-

UNSPSC 19.0-

Installation distance right/left-

Degree of pollution-

Current consumption-

Recommended breaker for input protection-

Nominal output current (IN)-

Nominal output voltage-

Connection in series-

Net weight-

Protection class-

Assembly instructions-

Conductor cross section AWG min.-

Screw thread-

Standard - Safety of transformers-

Standard – Limitation of mains harmonic currents-

Electromagnetic compatibility-

Contact discharge-

Input-

Criterion A-

ECLASS 4.0-

ECLASS 5.1-

ETIM 3.0-

UNSPSC 12.01-

UNSPSC 21.0-

MTBF (IEC 61709, SN 29500)-

Foot latch material-

Mounting position-

Conductor cross section flexible max.-

EMC requirements for noise immunity-

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

CSA-

Fast transients (burst)-

Electromagnetic HF field-

Output-

China RoHS-

ECLASS 6.0-

ECLASS 7.0-

UNSPSC 7.0901-

UNSPSC 18.0-

ECLASS 5.0-

ECLASS 9.0-

ETIM 7.0-

UNSPSC 20.0-

Derating-

Typical response time-

Housing material-

EMC requirements for noise emission-

Standard - Safe isolation-

Criterion B-

ECLASS 4.1-

ETIM 4.0-

Power loss nominal load max.-

Conductor cross section solid min.-

Stripping length-

Low Voltage Directive-

Test field strength-

Voltage-

Conducted interference-

UNSPSC 6.01-

Insulation voltage input/output-

Connection method-

Conductor cross section flexible min.-

Standard - Electrical safety-

Frequency range-

Protection against overvoltage at the output (OVP)-

Maximum power dissipation in no-load condition-

Conductor cross section solid max.-

Conductor cross section AWG max.-

Mains variation/undervoltage-

UL approvals-

Electrostatic discharge-

ECLASS 11.0-

UNSPSC 13.2-

2320827
3 in stock
2320827
Phoenix Contact

Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology...

Length of cable-

Insulation resistance-

Overvoltage category-

Contact carrier material-

Cable type (abbreviation)-

Conductor structure signal line-

Overall twist-

Sealing material-

Status display-

Number of positions-

Flammability rating according to UL 94-

Note-

Cable abbreviation-

UL AWM style-

Thickness, insulation-

Smallest bending radius, movable installation-

Number of bending cycles-

Acceleration-

Outer sheath, material-

Test voltage, cable-

Other resistance-

REACh SVHC-

ECLASS 10.0.1-

ECLASS 5.0-

ECLASS 6.0-

UNSPSC 11-

UNSPSC 20.0-

Rated current at 40°C-

ECLASS 9.0-

ETIM 6.0-

UNSPSC 7.0901-

Ambient temperature (operation)-

Rated voltage-

Protective circuit/component-

Insertion/withdrawal cycles-

Cable type-

AWG signal line-

Wire colors-

Shielding-

External sheath, color-

Traversing path-

Traversing rate-

Conductor resistance-

Flame resistance-

ECLASS 4.0-

ETIM 7.0-

UNSPSC 12.01-

Contact material-

Degree of protection-

Coding-

Conductor cross section-

Core diameter including insulation-

Optical shield covering-

Bending radius-

Cable weight-

Conductor material-

Special properties-

ECLASS 4.1-

ECLASS 7.0-

ETIM 4.0-

UNSPSC 19.0-

UNSPSC 21.0-

Degree of pollution-

Contact surface material-

Material of grip body-

Material, knurls-

Material conductor insulation-

Nominal voltage, cable-

Halogen-free-

China RoHS-

ECLASS 5.1-

ETIM 3.0-

UNSPSC 13.2-

External cable diameter D-

Smallest bending radius, fixed installation-

UNSPSC 6.01-

ECLASS 11.0-

Resistance to oil-

Height130 mm

Ambient temperature (start-up type tested)-40 °C

Degree of pollution2

Discharge current to PE< 3.5 mA

Mains buffering timetyp. 25 ms (400 V AC)

Protective circuit/componentVaristor

Connection in parallelYes, for redundancy and increased capacity

Output power960 W

MTBF (IEC 61709, SN 29500)> 890000 h (25 °C)

Insulation voltage output / PE500 V DC (routine test)

Conductor cross section solid min.0.2 mm²

Conductor cross section AWG max.10

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

UL approvalsUL Listed UL 508

Contact discharge8 kV (Test Level 4)

Test field strength10 V/m (Test Level 3)

Input2 kV (Test Level 3 - symmetrical)

Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

ECLASS 11.027040701

ECLASS 4.027040700

Depth179 mm

Degree of protectionIP20

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)

Input voltage range3x 320 V AC ... 575 V AC

AC frequency range45 Hz ... 65 Hz

REACh SVHCLead 7439-92-1

Recommended breaker for input protection6 A ... 16 A (AC: Characteristics B, C, D, K)

POWER BOOST (IBoost)22.5 A (-25 °C ... 40 °C permanent, UOUT = 48 V DC )

Connection in seriesyes

Active current limitationApprox. IBOOST = 22.5 A (for short-circuit)

Typical response time< 1 s

Housing materialSteel sheet, zinc-plated

Assembly instructionsalignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom

Connection methodScrew connection

Standard - Safety of transformersIEC 61558-2-17

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Electromagnetic HF fieldEN 61000-4-3

Signal1 kV (Test Level 2 - asymmetrical)

Criterion ANormal operating behavior within the specified limits.

ECLASS 4.127040700

ETIM 4.0EC002540

UNSPSC 12.0139121004

Width with alternative assembly176 mm

Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)

Installation height4000 m

Nominal power consumption1386 VA

Nominal output current (IN)20 A (-25 °C ... 60 °C, UOUT = 48 V DC)

Selective Fuse Breaking (ISFB)100 A (12 ms)

Protection against overvoltage at the output (OVP)< 60 V DC

Net weight2.5 kg

Insulation voltage input / PE3.5 kV AC (type test)

Mounting positionhorizontal DIN rail NS 35, EN 60715

Conductor cross section flexible min.0.2 mm²

Stripping length10 mm

EMC requirements for noise emissionEN 61000-6-3

Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)

Standard - Approval for medical useIEC 60601-1, 2 x MOOP

CSACAN/CSA-C22.2 No. 60950-1-07

Electrostatic dischargeEN 61000-4-2

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC

Fast transients (burst)EN 61000-4-4

Output1 kV (Test Level 2 - symmetrical)

Voltage10 V (Test Level 3)

China RoHSEnvironmentally Friendly Use Period = 25;

ECLASS 5.027242200

ETIM 3.0EC001039

ETIM 6.0EC002540

UNSPSC 6.0130211502

UNSPSC 20.039121004

Width96 mm

Height with alternative assembly130 mm

Climatic class3K3 (in acc. with EN 60721)

Current consumption3x 2.1 A (400 V AC)

Type of protectionTransient surge protection

Setting range of the output voltage (USet)30 V DC ... 56 V DC (> 48 V DC, constant capacity restricted)

Feedback voltage resistancemax. 60 V DC

Residual ripple< 50 mVPP (with nominal values)

Power loss nominal load max.70 W

Insulation voltage input/output4 kV AC (type test)

Protection classI

Conductor cross section AWG min.18

EMC requirements for noise immunityEN 61000-6-1

Standard - Electrical safetyIEC 60950-1/VDE 0805 (SELV)

Standard - Equipment safetyBG (design tested)

Standard - Safe isolationDIN VDE 0100-410

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU

Frequency range0.15 MHz ... 80 MHz

Surge voltage load (surge)EN 61000-4-5

Conducted interferenceEN 61000-4-6

ECLASS 6.027049000

ETIM 7.0EC002540

UNSPSC 21.039121004

Depth with alternative assembly99 mm

Ambient temperature (storage/transport)-40 °C ... 85 °C

Nominal input voltage range3x 400 V AC ... 500 V AC

Frequency range DC0 Hz

Inrush current< 20 A (typical)

Nominal output voltage48 V DC ±1 %

Derating60 °C ... 70 °C (2.5%/K)

Control deviation< 1 % (change in load, static 10 % ... 90 %)

Maximum power dissipation in no-load condition24 W

Efficiency> 93 % (at 400 V AC and nominal values)

Conductor cross section solid max.6 mm²

Conductor cross section flexible max.4 mm²

Screw threadM3

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178

Rail applicationsEN 50121-4

Discharge in air15 kV (Test Level 4)

CommentsCriterion A

I/O/Sasymmetrical

ECLASS 10.0.127040701

ECLASS 5.127242200

ECLASS 9.027040701

UNSPSC 1139121004

UNSPSC 18.039121004

ECLASS 7.027049002

UNSPSC 7.090139121004

UNSPSC 13.239121004

UNSPSC 19.039121004

Height-

Degree of protection-

Ambient temperature (operation)-

Max. permissible relative humidity (operation)-

Nominal power consumption-

Mains buffering time-

Protective circuit/component-

Feedback voltage resistance-

Output power-

Depth-

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Climatic class-

Input voltage range-

Inrush current-

Type of protection-

Width-

Installation distance top/bottom-

Ambient temperature (storage/transport)-

Nominal input voltage range-

Frequency range (fN)-

Input fuse-

Power factor (cos phi)-

Connection in parallel-

Residual ripple-

Control deviation-

Efficiency-

Standard – Safety extra-low voltage-

Discharge in air-

Comments-

Surge voltage load (surge)-

Voltage dips-

ECLASS 10.0.1-

ETIM 6.0-

UNSPSC 11-

UNSPSC 19.0-

Installation distance right/left-

Degree of pollution-

Current consumption-

Recommended breaker for input protection-

Nominal output current (IN)-

Nominal output voltage-

Connection in series-

Net weight-

Protection class-

Assembly instructions-

Conductor cross section AWG min.-

Screw thread-

Standard - Safety of transformers-

Standard – Limitation of mains harmonic currents-

Electromagnetic compatibility-

Contact discharge-

Input-

Criterion A-

ECLASS 4.0-

ECLASS 5.1-

ETIM 3.0-

UNSPSC 12.01-

UNSPSC 21.0-

MTBF (IEC 61709, SN 29500)-

Foot latch material-

Mounting position-

Conductor cross section flexible max.-

EMC requirements for noise immunity-

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

CSA-

Fast transients (burst)-

Electromagnetic HF field-

Output-

China RoHS-

ECLASS 6.0-

ECLASS 7.0-

UNSPSC 7.0901-

UNSPSC 18.0-

ECLASS 5.0-

ECLASS 9.0-

ETIM 7.0-

UNSPSC 20.0-

Derating-

Typical response time-

Housing material-

EMC requirements for noise emission-

Standard - Safe isolation-

Criterion B-

ECLASS 4.1-

ETIM 4.0-

Power loss nominal load max.-

Conductor cross section solid min.-

Stripping length-

Low Voltage Directive-

Test field strength-

Voltage-

Conducted interference-

UNSPSC 6.01-

Insulation voltage input/output-

Connection method-

Conductor cross section flexible min.-

Standard - Electrical safety-

Frequency range-

Protection against overvoltage at the output (OVP)-

Maximum power dissipation in no-load condition-

Conductor cross section solid max.-

Conductor cross section AWG max.-

Mains variation/undervoltage-

UL approvals-

Electrostatic discharge-

ECLASS 11.0-

UNSPSC 13.2-

2903002
56 in stock
2903002
Phoenix Contact

Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 15 V DC/100 W

Length of cable-

Insulation resistance-

Overvoltage category-

Contact carrier material-

Cable type (abbreviation)-

Conductor structure signal line-

Overall twist-

Sealing material-

Status display-

Number of positions-

Flammability rating according to UL 94-

Note-

Cable abbreviation-

UL AWM style-

Thickness, insulation-

Smallest bending radius, movable installation-

Number of bending cycles-

Acceleration-

Outer sheath, material-

Test voltage, cable-

Other resistance-

REACh SVHC-

ECLASS 10.0.1-

ECLASS 5.0-

ECLASS 6.0-

UNSPSC 11-

UNSPSC 20.0-

Rated current at 40°C-

ECLASS 9.0-

ETIM 6.0-

UNSPSC 7.0901-

Ambient temperature (operation)-

Rated voltage-

Protective circuit/component-

Insertion/withdrawal cycles-

Cable type-

AWG signal line-

Wire colors-

Shielding-

External sheath, color-

Traversing path-

Traversing rate-

Conductor resistance-

Flame resistance-

ECLASS 4.0-

ETIM 7.0-

UNSPSC 12.01-

Contact material-

Degree of protection-

Coding-

Conductor cross section-

Core diameter including insulation-

Optical shield covering-

Bending radius-

Cable weight-

Conductor material-

Special properties-

ECLASS 4.1-

ECLASS 7.0-

ETIM 4.0-

UNSPSC 19.0-

UNSPSC 21.0-

Degree of pollution-

Contact surface material-

Material of grip body-

Material, knurls-

Material conductor insulation-

Nominal voltage, cable-

Halogen-free-

China RoHS-

ECLASS 5.1-

ETIM 3.0-

UNSPSC 13.2-

External cable diameter D-

Smallest bending radius, fixed installation-

UNSPSC 6.01-

ECLASS 11.0-

Resistance to oil-

Height-

Ambient temperature (start-up type tested)-

Degree of pollution-

Discharge current to PE-

Mains buffering time-

Protective circuit/component-

Connection in parallel-

Output power-

MTBF (IEC 61709, SN 29500)-

Insulation voltage output / PE-

Conductor cross section solid min.-

Conductor cross section AWG max.-

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

UL approvals-

Contact discharge-

Test field strength-

Input-

Criterion B-

ECLASS 11.0-

ECLASS 4.0-

Depth-

Degree of protection-

Max. permissible relative humidity (operation)-

Input voltage range-

AC frequency range-

REACh SVHC-

Recommended breaker for input protection-

POWER BOOST (IBoost)-

Connection in series-

Active current limitation-

Typical response time-

Housing material-

Assembly instructions-

Connection method-

Standard - Safety of transformers-

Standard – Limitation of mains harmonic currents-

Electromagnetic HF field-

Signal-

Criterion A-

ECLASS 4.1-

ETIM 4.0-

UNSPSC 12.01-

Width with alternative assembly-

Ambient temperature (operation)-

Installation height-

Nominal power consumption-

Nominal output current (IN)-

Selective Fuse Breaking (ISFB)-

Protection against overvoltage at the output (OVP)-

Net weight-

Insulation voltage input / PE-

Mounting position-

Conductor cross section flexible min.-

Stripping length-

EMC requirements for noise emission-

Standard – Safety extra-low voltage-

Standard - Approval for medical use-

CSA-

Electrostatic discharge-

Low Voltage Directive-

Fast transients (burst)-

Output-

Voltage-

China RoHS-

ECLASS 5.0-

ETIM 3.0-

ETIM 6.0-

UNSPSC 6.01-

UNSPSC 20.0-

Width-

Height with alternative assembly-

Climatic class-

Current consumption-

Type of protection-

Setting range of the output voltage (USet)-

Feedback voltage resistance-

Residual ripple-

Power loss nominal load max.-

Insulation voltage input/output-

Protection class-

Conductor cross section AWG min.-

EMC requirements for noise immunity-

Standard - Electrical safety-

Standard - Equipment safety-

Standard - Safe isolation-

Electromagnetic compatibility-

Frequency range-

Surge voltage load (surge)-

Conducted interference-

ECLASS 6.0-

ETIM 7.0-

UNSPSC 21.0-

Depth with alternative assembly-

Ambient temperature (storage/transport)-

Nominal input voltage range-

Frequency range DC-

Inrush current-

Nominal output voltage-

Derating-

Control deviation-

Maximum power dissipation in no-load condition-

Efficiency-

Conductor cross section solid max.-

Conductor cross section flexible max.-

Screw thread-

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-

Rail applications-

Discharge in air-

Comments-

I/O/S-

ECLASS 10.0.1-

ECLASS 5.1-

ECLASS 9.0-

UNSPSC 11-

UNSPSC 18.0-

ECLASS 7.0-

UNSPSC 7.0901-

UNSPSC 13.2-

UNSPSC 19.0-

Height90 mm

Degree of protectionIP20

Ambient temperature (operation)-25 °C ... 70 °C (> 55 °C Derating: 2.5 %/K)

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)

Nominal power consumption206.3 VA

Mains buffering time> 20 ms (120 V AC)

Protective circuit/componentVaristor

Feedback voltage resistance< 25 V DC

Output power100 W

Depth84 mm

Inflammability class in acc. with UL 94 (housing / terminal blocks)V0

Climatic class3K3 (in acc. with EN 60721)

Input voltage range85 V AC ... 264 V AC

Inrush current< 30 A (typical)

Type of protectionTransient surge protection

Width55 mm

Installation distance top/bottom30 mm / 30 mm

Ambient temperature (storage/transport)-40 °C ... 85 °C

Nominal input voltage range100 V AC ... 240 V AC

Frequency range (fN)50 Hz ... 60 Hz 10 %

Input fuse4 A (slow-blow, internal)

Power factor (cos phi)0.54

Connection in parallelYes, for redundancy and increased capacity

Residual ripple< 75 mVPP (with nominal values)

Control deviation< 1 % (change in load, static 10 % ... 90 %)

Efficiencytyp. 89 % (120 V AC)

Standard – Safety extra-low voltageIEC 62368-1 (SELV) und EN 60204-1 (PELV)

Discharge in air8 kV (Test Level 3)

CommentsCriterion A

Surge voltage load (surge)EN 61000-4-5

Voltage dipsEN 61000-4-11

ECLASS 10.0.127040701

ETIM 6.0EC002540

UNSPSC 1139121004

UNSPSC 19.039121004

Installation distance right/left0 mm / 0 mm

Degree of pollution2

Current consumption2.19 A (100 V AC)

Recommended breaker for input protection6 A ... 16 A (Characteristics B, C, D, K)

Nominal output current (IN)6.67 A (-25 °C ... 55 °C)

Nominal output voltage15 V DC ±1 %

Connection in seriesyes

Net weight0.34 kg

Protection classII (in closed control cabinet)

Assembly instructionsalignable: 0 mm horizontally, 30 mm vertically

Conductor cross section AWG min.24

Screw threadM3

Standard - Safety of transformersEN 61558-2-16

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU

Contact discharge6 kV (Test Level 3)

Input2 kV (Test Level 3 - symmetrical)

Criterion ANormal operating behavior within the specified limits.

ECLASS 4.027040700

ECLASS 5.127049000

ETIM 3.0EC001039

UNSPSC 12.0139121004

UNSPSC 21.039121004

MTBF (IEC 61709, SN 29500)> 727000 h (40 °C)

Foot latch materialPOM (Polyoxymethylen)

Mounting positionhorizontal DIN rail NS 35, EN 60715

Conductor cross section flexible max.2.5 mm²

EMC requirements for noise immunityEN 61000-6-1

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

CSACAN/CSA-C22.2 No. 60950-1-07

Fast transients (burst)EN 61000-4-4

Electromagnetic HF fieldEN 61000-4-3

Output1 kV (Test Level 2 - symmetrical)

China RoHSEnvironmentally Friendly Use Period = 25;

ECLASS 6.027049000

ECLASS 7.027049002

UNSPSC 7.090139121004

UNSPSC 18.039121004

ECLASS 5.027049000

ECLASS 9.027040701

ETIM 7.0EC002540

UNSPSC 20.039121004

Derating55 °C ... 70 °C (2.5%/K)

Typical response time< 1 s

Housing materialPolycarbonate

EMC requirements for noise emissionEN 61000-6-3

Standard - Safe isolationDIN VDE 0100-410

Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

ECLASS 4.127040700

ETIM 4.0EC000599

Power loss nominal load max.< 12 W

Conductor cross section solid min.0.2 mm²

Stripping length8 mm

Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC

Test field strength10 V/m

Voltage10 V (Test Level 3)

Conducted interferenceEN 61000-4-6

UNSPSC 6.0130211502

Insulation voltage input/output4 kV AC (type test)

Connection methodScrew connection

Conductor cross section flexible min.0.2 mm²

Standard - Electrical safetyIEC 62368-1/VDE 0805 (SELV)

Frequency range10 kHz ... 80 MHz

Protection against overvoltage at the output (OVP)≤ 25 V DC

Maximum power dissipation in no-load condition< 0.4 W

Conductor cross section solid max.2.5 mm²

Conductor cross section AWG max.14

Mains variation/undervoltageEN 61000-4-11

UL approvalsUL/C-UL listed UL 508

Electrostatic dischargeEN 61000-4-2

ECLASS 11.027040701

UNSPSC 13.239121004

About the manufacturer

Phoenix Contact

Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

About the Product Category

Electrical wires and cables serve to establish electrical connections between switches, outlets, appliances, and more in homes, businesses, and industrial environments.

Electrical Wires & Cables

Relevant products

FAQ

Out if stock but available for backorder.

Sensor/actuator cable, 4-position, Variable cable type, shielded, Plug angled M8, on Socket straight M8, cable length: Free input (0.2 ... 40.0 m)

What can I help you find today?

Recommended parts