1234353 Phoenix Contact Data & Networking Devices


Part#:1234353
Manufacturer:Phoenix Contact
Category:Data & Networking Devices
Product Lifecycle:Active
Product description
Industrial LTE 4G router, EU device, 3G/UMTS/HSPA and 2G/GPRS/EDGE fallback, WLAN access point 802.11a/b/g/n, 150 Mbps, 2.4 GHz + 5 GHz, 2-port switch, firewall, NAT, IPsec and OpenVPN support, 4 DI, 2 DO
Product Details
- Ambient temperature (operation) -40 °C ... 70 °C
- Altitude ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
- Housing material Polycarbonate
- Net weight 0 g
- Supply voltage range 10 V DC ... 30 V DC (Via pluggable Push-in terminal block)
- Conductor cross section solid min. 0.14 mm²
- No. of ports 2
- SIM interface 1 1.8 volt, 3 volt
- LTE CAT4
- Web-based management yes
- Current output signal ≤ 50 mA (Not short-circuit proof)
- Identification CE-compliant
- ECLASS 10.0.1 19170502
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Electrical isolation VCC // LTE // Ethernet // PE
- Mounting type DIN rail mounting
- Color gray
- Conductor cross section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 0.75 mm²
- Conductor cross section AWG max. 16
- Interface Ethernet
- Interface description WLAN in accordance with IEEE 802.11 a/b/g/n
- Data rate 11 Mbps (2.4 GHz)
- Country support Europe
- Management Web-based management, SNMP
- Voltage input signal 10 V DC ... 30 V DC
- Height 130 mm
- Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
- MTTF 384 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
- Max. current consumption 1.5 A
- Conductor cross section flexible max. 1.50 mm²
- Conductor cross section AWG min. 26
- Stripping length 9 mm
- Antenna 50 Ω impedance SMA antenna socket
- EDGE Multislot Class 12
- Operating mode Access point
- Voltage output signal 10 V DC ... 30 V DC (depending on the operating voltage)
- Switching level "1" signal 10 V DC ... 30 V DC
- ECLASS 11.0 19170502
- Width 45 mm
- Permissible humidity (operation) 10 % ... 95 % (non-condensing)
- Wireless licences Europe
- Typical current consumption < 180 mA (24 V DC)
- Conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 1.5 mm²
- Conductor cross section solid max. 1.50 mm²
- Serial transmission speed 10/100 Mbps, auto negotiation
- UMTS HSPA 3GPP R8
- Frequency 5 GHz
- Number of outputs 2
- Number of inputs 4
- Designation CE
- Depth 130 mm
- Degree of protection IP20
- Electromagnetic compatibility Conformance with RED Directive 2014/53/EU
- Connection method RJ45 jack, shielded
- Conductor cross section flexible min. 0.14 mm²
- Interface 1 Ethernet interface, 10/100Base-T(X) in accordance with IEEE 802.3
- Transmission length 100 m (shielded twisted pair)
- Frequency range 800 MHz (LTE B20)
- GPRS Class 12, Class B
- Output name Digital output
- Description of the input Digital input
- China RoHS Environmentally friendly use period: unlimited = EFUP-e
- ECLASS 9.0 19170103
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
1234353 Phoenix Contact
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes

Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
Compare 1234353 with other products
Ambient temperature (oper...
Altitude
Housing material
Net weight
Supply voltage range
Conductor cross section s...
No. of ports
SIM interface 1
LTE
Web-based management
Current output signal
Identification
ECLASS 10.0.1
Ambient temperature (stor...
Electrical isolation
Mounting type
Color
Conductor cross section, ...
Conductor cross section A...
Interface
Interface description
Data rate
Country support
Management
Voltage input signal
Height
Permissible humidity (sto...
MTTF
Max. current consumption
Conductor cross section f...
Conductor cross section A...
Stripping length
Antenna
EDGE
Operating mode
Voltage output signal
Switching level "1" signa...
ECLASS 11.0
Width
Permissible humidity (ope...
Wireless licences
Typical current consumpti...
Conductor cross section f...
Conductor cross section s...
Serial transmission speed
UMTS
Frequency
Number of outputs
Number of inputs
Designation
Depth
Degree of protection
Electromagnetic compatibi...
Connection method
Conductor cross section f...
Interface 1
Transmission length
Frequency range
GPRS
Output name
Description of the input
China RoHS
ECLASS 9.0
Width with alternative as...
Climatic class
AC frequency range
Mains buffering time
Nominal output voltage
Connection in parallel
Connection in series
Typical response time
Environmental protection ...
Protection class
Low Voltage Directive
Flicker
I/O/S
Installation distance top...
Degree of pollution
Current consumption
Protective circuit/compon...
Dynamic Boost (IDyn.Boost...
Selective Fuse Breaking (...
Output power
MTBF (IEC 61709, SN 29500...
Assembly instructions
EMC requirements for nois...
Standard - Safety of tran...
Standard - safety for equ...
Standard – Limitation of ...
Mains variation/undervolt...
CSA
SIQ
DNV GL noise radiation
Discharge in air
Fast transients (burst)
Conducted interference
Voltage dips
Attenuated sinusoidal osc...
Test level 4
Attenuated oscillating wa...
REACh SVHC
ECLASS 5.1
ECLASS 7.0
UNSPSC 21.0
Depth with alternative as...
Installation height
Frequency range (fN)
Nominal power consumption
Recommended breaker for i...
Nominal output current (I...
Protection against overvo...
Residual ripple
Insulation voltage input/...
EMC requirements for nois...
Standard – Safety extra-l...
UL approvals
Shipbuilding approval
Harmonic currents
Electrostatic discharge
Electromagnetic HF field
Comments
Surge voltage load (surge...
Voltage dip
Test level 1
Test level 5
Input, output (test level...
Signals (test level 2)
ETIM 6.0
UNSPSC 20.0
Height with alternative a...
Inflammability class in a...
Discharge current to PE
Power factor (cos phi)
Static Boost (IStat.Boost...
Feedback voltage resistan...
Maximum power dissipation...
Efficiency
Insulation voltage input ...
EMC requirements, power p...
Standard - Electrical saf...
Standard - power supply d...
Conducted noise emission
DNV GL conducted interfer...
Test field strength
Output
Voltage
Pulse-shape magnetic fiel...
Asymmetrical conducted di...
Test level 6
Signals (test level 1)
ECLASS 6.0
UNSPSC 13.2
Installation distance rig...
Ambient temperature (star...
Max. permissible relative...
Input voltage range
Nominal input voltage ran...
Inrush current
Type of protection
Setting range of the outp...
Derating
Control deviation
Power loss nominal load m...
Insulation voltage output...
Mounting position
HART FSK Physical Layer T...
Standard - Safe isolation
Rail applications
Noise emission
Contact discharge
Additional text
Input
Signal
Number of periods
Test level 3
Input, output (test level...
Criterion B
ECLASS 5.0
ETIM 7.0
UNSPSC 18.0
Power frequency magnetic ...
Damped oscillating magnet...
Test level 2
Input, output (test level...
Criterion A
Criterion C
UNSPSC 19.0
Input fuse
UNSPSC 11
Screw thread
ECLASS 4.0
ETIM 3.0
UNSPSC 12.01
Foot latch material
Standard – Electronic equ...
UNSPSC 7.0901
ECLASS 4.1
ETIM 4.0
UNSPSC 6.01
Selected product

1234353
Phoenix Contact
Industrial LTE 4G router, EU device, 3G/UMTS/HSPA and 2G/GPRS/EDGE fallback, WLAN access point 802.1...
Ambient temperature (operation)-40 °C ... 70 °C
Altitude≤ 5000 m (For restrictions, ...
Housing materialPolycarbonate
Net weight0 g
Supply voltage range10 V DC ... 30 V DC (Via plu...
Conductor cross section solid min.0.14 mm²
No. of ports2
SIM interface 11.8 volt, 3 volt
LTECAT4
Web-based managementyes
Current output signal≤ 50 mA (Not short-circuit p...
IdentificationCE-compliant
ECLASS 10.0.119170502
Ambient temperature (storage/transport)-40 °C ... 85 °C
Electrical isolationVCC // LTE // Ethernet // PE
Mounting typeDIN rail mounting
Colorgray
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 0.75 mm²
Conductor cross section AWG max.16
InterfaceEthernet
Interface descriptionWLAN in accordance with IEEE...
Data rate11 Mbps (2.4 GHz)
Country supportEurope
ManagementWeb-based management, SNMP
Voltage input signal10 V DC ... 30 V DC
Height130 mm
Permissible humidity (storage/transport)10 % ... 95 % (non-condensin...
MTTF384 Years (SN 29500 standard...
Max. current consumption1.5 A
Conductor cross section flexible max.1.50 mm²
Conductor cross section AWG min.26
Stripping length9 mm
Antenna50 Ω impedance SMA antenna s...
EDGEMultislot Class 12
Operating modeAccess point
Voltage output signal10 V DC ... 30 V DC (dependi...
Switching level "1" signal10 V DC ... 30 V DC
ECLASS 11.019170502
Width45 mm
Permissible humidity (operation)10 % ... 95 % (non-condensin...
Wireless licencesEurope
Typical current consumption< 180 mA (24 V DC)
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm²
Conductor cross section solid max.1.50 mm²
Serial transmission speed10/100 Mbps, auto negotiatio...
UMTSHSPA 3GPP R8
Frequency5 GHz
Number of outputs2
Number of inputs4
DesignationCE
Depth130 mm
Degree of protectionIP20
Electromagnetic compatibilityConformance with RED Directi...
Connection methodRJ45 jack, shielded
Conductor cross section flexible min.0.14 mm²
Interface 1Ethernet interface, 10/100Ba...
Transmission length100 m (shielded twisted pair...
Frequency range800 MHz (LTE B20)
GPRSClass 12, Class B
Output nameDigital output
Description of the inputDigital input
China RoHSEnvironmentally friendly use...
ECLASS 9.019170103
Width with alternative assembly-
Climatic class-
AC frequency range-
Mains buffering time-
Nominal output voltage-
Connection in parallel-
Connection in series-
Typical response time-
Environmental protection directive-
Protection class-
Low Voltage Directive-
Flicker-
I/O/S-
Installation distance top/bottom-
Degree of pollution-
Current consumption-
Protective circuit/component-
Dynamic Boost (IDyn.Boost)-
Selective Fuse Breaking (ISFB)-
Output power-
MTBF (IEC 61709, SN 29500)-
Assembly instructions-
EMC requirements for noise emission-
Standard - Safety of transformers-
Standard - safety for equipment for measurement, control, and laboratory use-
Standard – Limitation of mains harmonic currents-
Mains variation/undervoltage-
CSA-
SIQ-
DNV GL noise radiation-
Discharge in air-
Fast transients (burst)-
Conducted interference-
Voltage dips-
Attenuated sinusoidal oscillations (ring wave)-
Test level 4-
Attenuated oscillating wave-
REACh SVHC-
ECLASS 5.1-
ECLASS 7.0-
UNSPSC 21.0-
Depth with alternative assembly-
Installation height-
Frequency range (fN)-
Nominal power consumption-
Recommended breaker for input protection-
Nominal output current (IN)-
Protection against overvoltage at the output (OVP)-
Residual ripple-
Insulation voltage input/output-
EMC requirements for noise immunity-
Standard – Safety extra-low voltage-
UL approvals-
Shipbuilding approval-
Harmonic currents-
Electrostatic discharge-
Electromagnetic HF field-
Comments-
Surge voltage load (surge)-
Voltage dip-
Test level 1-
Test level 5-
Input, output (test level 2)-
Signals (test level 2)-
ETIM 6.0-
UNSPSC 20.0-
Height with alternative assembly-
Inflammability class in acc. with UL 94 (housing / terminal blocks)-
Discharge current to PE-
Power factor (cos phi)-
Static Boost (IStat.Boost)-
Feedback voltage resistance-
Maximum power dissipation in no-load condition-
Efficiency-
Insulation voltage input / PE-
EMC requirements, power plant-
Standard - Electrical safety-
Standard - power supply devices for low voltage with DC output-
Conducted noise emission-
DNV GL conducted interference-
Test field strength-
Output-
Voltage-
Pulse-shape magnetic field-
Asymmetrical conducted disturbance variables-
Test level 6-
Signals (test level 1)-
ECLASS 6.0-
UNSPSC 13.2-
Installation distance right/left-
Ambient temperature (start-up type tested)-
Max. permissible relative humidity (operation)-
Input voltage range-
Nominal input voltage range-
Inrush current-
Type of protection-
Setting range of the output voltage (USet)-
Derating-
Control deviation-
Power loss nominal load max.-
Insulation voltage output / PE-
Mounting position-
HART FSK Physical Layer Test Specification Compliance-
Standard - Safe isolation-
Rail applications-
Noise emission-
Contact discharge-
Additional text-
Input-
Signal-
Number of periods-
Test level 3-
Input, output (test level 3)-
Criterion B-
ECLASS 5.0-
ETIM 7.0-
UNSPSC 18.0-
Power frequency magnetic field-
Damped oscillating magnetic field-
Test level 2-
Input, output (test level 1)-
Criterion A-
Criterion C-
UNSPSC 19.0-
Input fuse-
UNSPSC 11-
Screw thread-
ECLASS 4.0-
ETIM 3.0-
UNSPSC 12.01-
Foot latch material-
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-
UNSPSC 7.0901-
ECLASS 4.1-
ETIM 4.0-
UNSPSC 6.01-
About the manufacturer

Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
About the Product Category
Devices for networking, which can be either hardware or software components, enable communication and data sharing among devices within a computer network. Their role is to create and sustain connectivity, improve the performance of the network, and safeguard data.

Relevant products
FAQ
Out if stock but available for backorder.
Industrial LTE 4G router, EU device, 3G/UMTS/HSPA and 2G/GPRS/EDGE fallback, WLAN access point 802.11a/b/g/n, 150 Mbps, 2.4 GHz + 5 GHz, 2-port switch, firewall, NAT, IPsec and OpenVPN support, 4 DI, 2 DO
What can I help you find today?