1234224 Phoenix Contact Data & Networking Devices

1234224 on Power Resources International
Phoenix Contact

Part#:1234224

Manufacturer:Phoenix Contact

Category:Data & Networking Devices

Product Lifecycle:Active

Product description

NearFi, base coupler for contactless power and Ethernet data transmission in real time over up to 10 mm, 24 V DC, 2 A, 100 Mbps full duplex, M12 fast-connection technology, IP65 degree of protection. A remote coupler is required for operation.

Product Details

  • Mounting type
    Wall mounting
  • Width
    79 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Noise immunity
    Immunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial)
  • Connection method
    M12 connector, (A-coded)
  • Transmission length
    100 m (shielded twisted pair)
  • Center offset
    ± 5 mm
  • Number of outputs
    1
  • Switching level "1" signal
    19 V DC ... 30 V DC
  • Height
    87 mm
  • Degree of protection
    IP65
  • Identification
    CE-compliant
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Mounting position
    any
  • Net weight
    490 g
  • Interface 1
    Ethernet interface, 100Base-T(X) in accordance with IEEE 802.3
  • Transmission speed
    100 Mbps
  • Delay time
    ≤ 3 µs (typical)
  • Description of the input
    Digital input
  • Additional text
    RED 2014/53/EU
  • Contact discharge
    4 kV (Test Level 2)
  • Pollution degree
    1
  • Depth
    40 mm
  • Protection class
    II
  • Typical current consumption
    170 mA (without remote, at 24 V DC, at 25°C)
  • Material
    PBT (Housing)
  • Transmission medium
    Copper
  • Range
    ≤ 10 mm
  • Frequency range
    0.15 MHz ... 80 MHz
  • Output name
    Digital output
  • Number of inputs
    1
  • Standards/regulations
    EN 60204-1 (PELV)
  • Test field strength
    3 V/m (Test Level 2)
  • ECLASS 11.0
    27040701
  • Ambient temperature (operation)
    Tbd.
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Supply voltage range
    19 V DC ... 30 V DC
  • Operating mode
    full duplex
  • Switch-on time
    ≤ 1 s (Operational readiness time of the coupler system, power polling)
  • Efficiency
    ≤ 90 %
  • Contact type
    Open collector output, external pull-up resistor
  • Current output signal
    25 mA
  • Designation
    Wireless approval, Europe
  • Test result
    10g
  • Voltage
    10 V (Test Level 3)
  • ECLASS 9.0
    27040701
  • Protective circuit
    Transient protection, polarity protection
  • No. of ports
    1
  • Angular offset
    ± 7 °
  • Wireless modules that can be connected
    1 (Remote coupler)
  • Voltage input signal
    19 V DC ... 30 V DC
  • Comments
    Criterion B
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • Type of test
    Continuous shock according to EN 60068-2-27/IEC 60068-2-27
  • Conducted noise emission
    EN 55016 EN 61000-6-4 Class A
  • ECLASS 10.0.1
    27040701
  • Voltage output signal
    19 V DC ... 30 V DC (depending on the operating voltage)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

1234224 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

Compare 1234224 with other products

Mounting type

Width

Ambient temperature (stor...

Noise immunity

Connection method

Transmission length

Center offset

Number of outputs

Switching level "1" signa...

Height

Degree of protection

Identification

Permissible humidity (ope...

Mounting position

Net weight

Interface 1

Transmission speed

Delay time

Description of the input

Additional text

Contact discharge

Pollution degree

Depth

Protection class

Typical current consumpti...

Material

Transmission medium

Range

Frequency range

Output name

Number of inputs

Standards/regulations

Test field strength

ECLASS 11.0

Ambient temperature (oper...

Permissible humidity (sto...

Supply voltage range

Operating mode

Switch-on time

Efficiency

Contact type

Current output signal

Designation

Test result

Voltage

ECLASS 9.0

Protective circuit

No. of ports

Angular offset

Wireless modules that can...

Voltage input signal

Comments

China RoHS

Type of test

Conducted noise emission

ECLASS 10.0.1

Voltage output signal

Width with alternative as...

Climatic class

AC frequency range

Mains buffering time

Nominal output voltage

Connection in parallel

Connection in series

Typical response time

Environmental protection ...

Stripping length

Low Voltage Directive

Flicker

I/O/S

Installation distance top...

Degree of pollution

Current consumption

Protective circuit/compon...

Dynamic Boost (IDyn.Boost...

Selective Fuse Breaking (...

Output power

MTBF (IEC 61709, SN 29500...

Assembly instructions

Conductor cross section A...

EMC requirements for nois...

Standard - Safety of tran...

Standard - safety for equ...

Standard – Limitation of ...

Mains variation/undervolt...

CSA

SIQ

DNV GL noise radiation

Discharge in air

Fast transients (burst)

Conducted interference

Voltage dips

Attenuated sinusoidal osc...

Test level 4

Attenuated oscillating wa...

REACh SVHC

ECLASS 5.1

ECLASS 7.0

UNSPSC 21.0

Depth with alternative as...

Installation height

Frequency range (fN)

Nominal power consumption

Recommended breaker for i...

Nominal output current (I...

Protection against overvo...

Residual ripple

Insulation voltage input/...

Conductor cross section s...

EMC requirements for nois...

Standard – Safety extra-l...

UL approvals

Shipbuilding approval

Harmonic currents

Electrostatic discharge

Electromagnetic HF field

Surge voltage load (surge...

Voltage dip

Test level 1

Test level 5

Input, output (test level...

Signals (test level 2)

ETIM 6.0

UNSPSC 20.0

Height with alternative a...

Inflammability class in a...

Discharge current to PE

Power factor (cos phi)

Static Boost (IStat.Boost...

Feedback voltage resistan...

Maximum power dissipation...

Insulation voltage input ...

Conductor cross section s...

Conductor cross section A...

EMC requirements, power p...

Standard - Electrical saf...

Standard - power supply d...

Electromagnetic compatibi...

DNV GL conducted interfer...

Output

Pulse-shape magnetic fiel...

Asymmetrical conducted di...

Test level 6

Signals (test level 1)

ECLASS 6.0

UNSPSC 13.2

Installation distance rig...

Ambient temperature (star...

Max. permissible relative...

Input voltage range

Nominal input voltage ran...

Inrush current

Type of protection

Setting range of the outp...

Derating

Control deviation

Power loss nominal load m...

Insulation voltage output...

Conductor cross section f...

Conductor cross section f...

HART FSK Physical Layer T...

Standard - Safe isolation

Rail applications

Noise emission

Input

Signal

Frequency

Number of periods

Test level 3

Input, output (test level...

Criterion B

ECLASS 5.0

ETIM 7.0

UNSPSC 18.0

Power frequency magnetic ...

Damped oscillating magnet...

Test level 2

Input, output (test level...

Criterion A

Criterion C

UNSPSC 19.0

Standard – Electronic equ...

ECLASS 4.0

POWER BOOST (IBoost)

Active current limitation

Housing material

ECLASS 4.1

ETIM 4.0

UNSPSC 12.01

Standard - Approval for m...

ETIM 3.0

UNSPSC 6.01

Standard - Equipment safe...

Frequency range DC

Screw thread

Standard – Protection aga...

UNSPSC 11

UNSPSC 7.0901

Selected product

1234224
0 in stock
1234224
Phoenix Contact

NearFi, base coupler for contactless power and Ethernet data transmission in real time over up to 10...

Mounting typeWall mounting

Width79 mm

Ambient temperature (storage/transport)-40 °C ... 85 °C

Noise immunityImmunity according to EN 610...

Connection methodM12 connector, (A-coded)

Transmission length100 m (shielded twisted pair...

Center offset± 5 mm

Number of outputs1

Switching level "1" signal19 V DC ... 30 V DC

Height87 mm

Degree of protectionIP65

IdentificationCE-compliant

Permissible humidity (operation)5 % ... 95 % (non-condensing...

Mounting positionany

Net weight490 g

Interface 1Ethernet interface, 100Base-...

Transmission speed100 Mbps

Delay time≤ 3 µs (typical)

Description of the inputDigital input

Additional textRED 2014/53/EU

Contact discharge4 kV (Test Level 2)

Pollution degree1

Depth40 mm

Protection classII

Typical current consumption170 mA (without remote, at 2...

MaterialPBT (Housing)

Transmission mediumCopper

Range≤ 10 mm

Frequency range0.15 MHz ... 80 MHz

Output nameDigital output

Number of inputs1

Standards/regulationsEN 60204-1 (PELV)

Test field strength3 V/m (Test Level 2)

ECLASS 11.027040701

Ambient temperature (operation)Tbd.

Permissible humidity (storage/transport)5 % ... 95 % (non-condensing...

Supply voltage range19 V DC ... 30 V DC

Operating modefull duplex

Switch-on time≤ 1 s (Operational readiness...

Efficiency≤ 90 %

Contact typeOpen collector output, exter...

Current output signal25 mA

DesignationWireless approval, Europe

Test result10g

Voltage10 V (Test Level 3)

ECLASS 9.027040701

Protective circuitTransient protection, polari...

No. of ports1

Angular offset± 7 °

Wireless modules that can be connected1 (Remote coupler)

Voltage input signal19 V DC ... 30 V DC

CommentsCriterion B

China RoHSEnvironmentally Friendly Use...

Type of testContinuous shock according t...

Conducted noise emissionEN 55016 EN 61000-6-4 Class ...

ECLASS 10.0.127040701

Voltage output signal19 V DC ... 30 V DC (dependi...

Width with alternative assembly-

Climatic class-

AC frequency range-

Mains buffering time-

Nominal output voltage-

Connection in parallel-

Connection in series-

Typical response time-

Environmental protection directive-

Stripping length-

Low Voltage Directive-

Flicker-

I/O/S-

Installation distance top/bottom-

Degree of pollution-

Current consumption-

Protective circuit/component-

Dynamic Boost (IDyn.Boost)-

Selective Fuse Breaking (ISFB)-

Output power-

MTBF (IEC 61709, SN 29500)-

Assembly instructions-

Conductor cross section AWG min.-

EMC requirements for noise emission-

Standard - Safety of transformers-

Standard - safety for equipment for measurement, control, and laboratory use-

Standard – Limitation of mains harmonic currents-

Mains variation/undervoltage-

CSA-

SIQ-

DNV GL noise radiation-

Discharge in air-

Fast transients (burst)-

Conducted interference-

Voltage dips-

Attenuated sinusoidal oscillations (ring wave)-

Test level 4-

Attenuated oscillating wave-

REACh SVHC-

ECLASS 5.1-

ECLASS 7.0-

UNSPSC 21.0-

Depth with alternative assembly-

Installation height-

Frequency range (fN)-

Nominal power consumption-

Recommended breaker for input protection-

Nominal output current (IN)-

Protection against overvoltage at the output (OVP)-

Residual ripple-

Insulation voltage input/output-

Conductor cross section solid max.-

EMC requirements for noise immunity-

Standard – Safety extra-low voltage-

UL approvals-

Shipbuilding approval-

Harmonic currents-

Electrostatic discharge-

Electromagnetic HF field-

Surge voltage load (surge)-

Voltage dip-

Test level 1-

Test level 5-

Input, output (test level 2)-

Signals (test level 2)-

ETIM 6.0-

UNSPSC 20.0-

Height with alternative assembly-

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Discharge current to PE-

Power factor (cos phi)-

Static Boost (IStat.Boost)-

Feedback voltage resistance-

Maximum power dissipation in no-load condition-

Insulation voltage input / PE-

Conductor cross section solid min.-

Conductor cross section AWG max.-

EMC requirements, power plant-

Standard - Electrical safety-

Standard - power supply devices for low voltage with DC output-

Electromagnetic compatibility-

DNV GL conducted interference-

Output-

Pulse-shape magnetic field-

Asymmetrical conducted disturbance variables-

Test level 6-

Signals (test level 1)-

ECLASS 6.0-

UNSPSC 13.2-

Installation distance right/left-

Ambient temperature (start-up type tested)-

Max. permissible relative humidity (operation)-

Input voltage range-

Nominal input voltage range-

Inrush current-

Type of protection-

Setting range of the output voltage (USet)-

Derating-

Control deviation-

Power loss nominal load max.-

Insulation voltage output / PE-

Conductor cross section flexible min.-

Conductor cross section flexible max.-

HART FSK Physical Layer Test Specification Compliance-

Standard - Safe isolation-

Rail applications-

Noise emission-

Input-

Signal-

Frequency-

Number of periods-

Test level 3-

Input, output (test level 3)-

Criterion B-

ECLASS 5.0-

ETIM 7.0-

UNSPSC 18.0-

Power frequency magnetic field-

Damped oscillating magnetic field-

Test level 2-

Input, output (test level 1)-

Criterion A-

Criterion C-

UNSPSC 19.0-

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

ECLASS 4.0-

POWER BOOST (IBoost)-

Active current limitation-

Housing material-

ECLASS 4.1-

ETIM 4.0-

UNSPSC 12.01-

Standard - Approval for medical use-

ETIM 3.0-

UNSPSC 6.01-

Standard - Equipment safety-

Frequency range DC-

Screw thread-

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-

UNSPSC 11-

UNSPSC 7.0901-

2904622
17 in stock
2904622
Phoenix Contact

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (sele...

Mounting type-

Width70 mm

Ambient temperature (storage/transport)-40 °C ... 85 °C

Noise immunity-

Connection methodPush-in connection

Transmission length-

Center offset-

Number of outputs-

Switching level "1" signal-

Height130 mm

Degree of protectionIP20

Identification-

Permissible humidity (operation)-

Mounting positionhorizontal DIN rail NS 35, E...

Net weight1.1 kg

Interface 1-

Transmission speed-

Delay time-

Description of the input-

Additional textTest Level 2

Contact discharge8 kV (Test Level 4)

Pollution degree-

Depth125 mm

Protection classI

Typical current consumption-

Material-

Transmission medium-

Range-

Frequency range50 Hz ... 60 Hz

Output name-

Number of inputs-

Standards/regulations-

Test field strength110 A/m

ECLASS 11.027040701

Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C De...

Permissible humidity (storage/transport)-

Supply voltage range-

Operating mode-

Switch-on time-

Efficiencytyp. 93.9 % (400 V AC)

Contact type-

Current output signal-

Designation-

Test result-

Voltage2.5 kV

ECLASS 9.027040701

Protective circuit-

No. of ports-

Angular offset-

Wireless modules that can be connected-

Voltage input signal-

CommentsCriterion A

China RoHSEnvironmentally Friendly Use...

Type of test-

Conducted noise emissionEN 55016

ECLASS 10.0.127040701

Voltage output signal-

Width with alternative assembly122 mm

Climatic class3K3 (in acc. with EN 60721)

AC frequency range50 Hz ... 60 Hz -10 % ... +1...

Mains buffering timetyp. 33 ms (3x 400 V AC)

Nominal output voltage24 V DC

Connection in parallelYes, for redundancy and incr...

Connection in seriesyes

Typical response time300 ms (from SLEEP MODE)

Environmental protection directiveRoHS Directive 2011/65/EU

Stripping length8 mm

Low Voltage DirectiveConformance with Low Voltage...

FlickerEN 61000-3-3

I/O/Sasymmetrical

Installation distance top/bottom50 mm / 50 mm

Degree of pollution2

Current consumption3x 0.99 A (400 V AC)

Protective circuit/componentVaristor, gas-filled surge a...

Dynamic Boost (IDyn.Boost)30 A (5 s)

Selective Fuse Breaking (ISFB)120 A (15 ms)

Output power480 W

MTBF (IEC 61709, SN 29500)> 985000 h (25 °C)

Assembly instructionsalignable: PN ≥50%, 5 mm hor...

Conductor cross section AWG min.24

EMC requirements for noise emissionEN 61000-6-3

Standard - Safety of transformersIEC 61558-2-16 pending

Standard - safety for equipment for measurement, control, and laboratory useIEC 61010-1

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Mains variation/undervoltageSEMI F47-0706, EN 61000-4-11

CSACAN/CSA-C22.2 No. 60950-1-07

SIQBG (type approved)

DNV GL noise radiationClass B

Discharge in air15 kV (Test Level 4)

Fast transients (burst)EN 61000-4-4

Conducted interferenceEN 61000-4-6

Voltage dipsEN 61000-4-11

Attenuated sinusoidal oscillations (ring wave)EN 61000-4-12

Test level 415 kHz 150 kHz (Test Level 4...

Attenuated oscillating waveEN 61000-4-18

REACh SVHCLead 7439-92-1

ECLASS 5.127242200

ECLASS 7.027049002

UNSPSC 21.039121004

Depth with alternative assembly73 mm

Installation height≤ 5000 m (> 2000 m, observe ...

Frequency range (fN)50 Hz ... 60 Hz -10 % ... +1...

Nominal power consumption541 VA

Recommended breaker for input protection3x 4 A ... 20 A (Characteris...

Nominal output current (IN)20 A

Protection against overvoltage at the output (OVP)≤ 32 V DC

Residual ripple< 60 mVPP (with nominal valu...

Insulation voltage input/output4 kV AC (type test)

Conductor cross section solid max.1 mm²

EMC requirements for noise immunityEN 61000-6-1

Standard – Safety extra-low voltageIEC 61010-1 (SELV)

UL approvalsUL Listed UL 508

Shipbuilding approvalDNV GL, PRS, BV, LR, ABS

Harmonic currentsEN 61000-3-2

Electrostatic dischargeEN 61000-4-2

Electromagnetic HF fieldEN 61000-4-3

Surge voltage load (surge)EN 61000-4-5

Voltage dip0 %

Test level 115 Hz 150 Hz (Test Level 4)

Test level 516.7 Hz 50 Hz 60 Hz (Test Le...

Input, output (test level 2)10 MHz

Signals (test level 2)100 kHz 1 MHz (Test Level 3 ...

ETIM 6.0EC002540

UNSPSC 20.039121004

Height with alternative assembly130 mm

Inflammability class in acc. with UL 94 (housing / terminal blocks)V0

Discharge current to PE< 3.5 mA

Power factor (cos phi)0.94

Static Boost (IStat.Boost)25 A

Feedback voltage resistance≤ 35 V DC

Maximum power dissipation in no-load condition< 7 W (400 V AC)

Insulation voltage input / PE3.5 kV AC (type test)

Conductor cross section solid min.0.2 mm²

Conductor cross section AWG max.16

EMC requirements, power plantIEC 61850-3

Standard - Electrical safetyIEC 61010-2-201 (SELV)

Standard - power supply devices for low voltage with DC outputEN 61204-3

Electromagnetic compatibilityConformance with EMC Directi...

DNV GL conducted interferenceClass A

Output1 kV (Test Level 3 - symmetr...

Pulse-shape magnetic fieldEN 61000-4-9

Asymmetrical conducted disturbance variablesEN 61000-4-16

Test level 616.7 Hz 50 Hz 60 Hz (Test Le...

Signals (test level 1)100 kHz 1 MHz (Test Level 3 ...

ECLASS 6.027049000

UNSPSC 13.239121004

Installation distance right/left5 mm / 5 mm

Ambient temperature (start-up type tested)-40 °C

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-conden...

Input voltage range3x 400 V AC ... 500 V AC -20...

Nominal input voltage range3x 400 V AC ... 500 V AC

Inrush currenttyp. 2 A (at 25 °C)

Type of protectionTransient surge protection

Setting range of the output voltage (USet)24 V DC ... 29.5 V DC (const...

Derating> 60 °C ... 70 °C (2.5%/K)

Control deviation< 0.5 % (Static load change ...

Power loss nominal load max.< 32 W (400 V AC)

Insulation voltage output / PE0.5 kV DC (type test)

Conductor cross section flexible min.0.2 mm²

Conductor cross section flexible max.1.5 mm²

HART FSK Physical Layer Test Specification ComplianceOutput voltage UOut complian...

Standard - Safe isolationIEC 61558-2-16 pending

Rail applicationsEN 50121-3-2

Noise emissionEN 55016

Input2 kV (Test Level 4 - symmetr...

Signal1 kV (Test Level 2 - asymmet...

Frequency50 Hz

Number of periods0,5 / 1 / 5 / 50 / 250 perio...

Test level 31.5 kHz 15 kHz (Test Level 4...

Input, output (test level 3)100 kHz 1 MHz (Test Level 3 ...

Criterion BTemporary impairment to oper...

ECLASS 5.027242200

ETIM 7.0EC002540

UNSPSC 18.039121004

Power frequency magnetic fieldEN 61000-4-8

Damped oscillating magnetic fieldEN 61000-4-10

Test level 2150 Hz 1.5 kHz (Test Level 4...

Input, output (test level 1)100 kHz 1 MHz (Test Level 3 ...

Criterion ANormal operating behavior wi...

Criterion CTemporary adverse effects on...

UNSPSC 19.039121004

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

ECLASS 4.0-

POWER BOOST (IBoost)-

Active current limitation-

Housing material-

ECLASS 4.1-

ETIM 4.0-

UNSPSC 12.01-

Standard - Approval for medical use-

ETIM 3.0-

UNSPSC 6.01-

Standard - Equipment safety-

Frequency range DC-

Screw thread-

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-

UNSPSC 11-

UNSPSC 7.0901-

2320827
3 in stock
2320827
Phoenix Contact

Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology...

Mounting type-

Width96 mm

Ambient temperature (storage/transport)-40 °C ... 85 °C

Noise immunity-

Connection methodScrew connection

Transmission length-

Center offset-

Number of outputs-

Switching level "1" signal-

Height130 mm

Degree of protectionIP20

Identification-

Permissible humidity (operation)-

Mounting positionhorizontal DIN rail NS 35, E...

Net weight2.5 kg

Interface 1-

Transmission speed-

Delay time-

Description of the input-

Additional text-

Contact discharge8 kV (Test Level 4)

Pollution degree-

Depth179 mm

Protection classI

Typical current consumption-

Material-

Transmission medium-

Range-

Frequency range0.15 MHz ... 80 MHz

Output name-

Number of inputs-

Standards/regulations-

Test field strength10 V/m (Test Level 3)

ECLASS 11.027040701

Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C De...

Permissible humidity (storage/transport)-

Supply voltage range-

Operating mode-

Switch-on time-

Efficiency> 93 % (at 400 V AC and nomi...

Contact type-

Current output signal-

Designation-

Test result-

Voltage10 V (Test Level 3)

ECLASS 9.027040701

Protective circuit-

No. of ports-

Angular offset-

Wireless modules that can be connected-

Voltage input signal-

CommentsCriterion A

China RoHSEnvironmentally Friendly Use...

Type of test-

Conducted noise emission-

ECLASS 10.0.127040701

Voltage output signal-

Width with alternative assembly176 mm

Climatic class3K3 (in acc. with EN 60721)

AC frequency range45 Hz ... 65 Hz

Mains buffering timetyp. 25 ms (400 V AC)

Nominal output voltage48 V DC ±1 %

Connection in parallelYes, for redundancy and incr...

Connection in seriesyes

Typical response time< 1 s

Environmental protection directive-

Stripping length10 mm

Low Voltage DirectiveConformance with Low Voltage...

Flicker-

I/O/Sasymmetrical

Installation distance top/bottom-

Degree of pollution2

Current consumption3x 2.1 A (400 V AC)

Protective circuit/componentVaristor

Dynamic Boost (IDyn.Boost)-

Selective Fuse Breaking (ISFB)100 A (12 ms)

Output power960 W

MTBF (IEC 61709, SN 29500)> 890000 h (25 °C)

Assembly instructionsalignable: PN ≥50%, 5 mm hor...

Conductor cross section AWG min.18

EMC requirements for noise emissionEN 61000-6-3

Standard - Safety of transformersIEC 61558-2-17

Standard - safety for equipment for measurement, control, and laboratory use-

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Mains variation/undervoltage-

CSACAN/CSA-C22.2 No. 60950-1-07

SIQ-

DNV GL noise radiation-

Discharge in air15 kV (Test Level 4)

Fast transients (burst)EN 61000-4-4

Conducted interferenceEN 61000-4-6

Voltage dips-

Attenuated sinusoidal oscillations (ring wave)-

Test level 4-

Attenuated oscillating wave-

REACh SVHCLead 7439-92-1

ECLASS 5.127242200

ECLASS 7.027049002

UNSPSC 21.039121004

Depth with alternative assembly99 mm

Installation height4000 m

Frequency range (fN)-

Nominal power consumption1386 VA

Recommended breaker for input protection6 A ... 16 A (AC: Characteri...

Nominal output current (IN)20 A (-25 °C ... 60 °C, UOUT...

Protection against overvoltage at the output (OVP)< 60 V DC

Residual ripple< 50 mVPP (with nominal valu...

Insulation voltage input/output4 kV AC (type test)

Conductor cross section solid max.6 mm²

EMC requirements for noise immunityEN 61000-6-1

Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60...

UL approvalsUL Listed UL 508

Shipbuilding approval-

Harmonic currents-

Electrostatic dischargeEN 61000-4-2

Electromagnetic HF fieldEN 61000-4-3

Surge voltage load (surge)EN 61000-4-5

Voltage dip-

Test level 1-

Test level 5-

Input, output (test level 2)-

Signals (test level 2)-

ETIM 6.0EC002540

UNSPSC 20.039121004

Height with alternative assembly130 mm

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Discharge current to PE< 3.5 mA

Power factor (cos phi)-

Static Boost (IStat.Boost)-

Feedback voltage resistancemax. 60 V DC

Maximum power dissipation in no-load condition24 W

Insulation voltage input / PE3.5 kV AC (type test)

Conductor cross section solid min.0.2 mm²

Conductor cross section AWG max.10

EMC requirements, power plant-

Standard - Electrical safetyIEC 60950-1/VDE 0805 (SELV)

Standard - power supply devices for low voltage with DC output-

Electromagnetic compatibilityConformance with EMC Directi...

DNV GL conducted interference-

Output1 kV (Test Level 2 - symmetr...

Pulse-shape magnetic field-

Asymmetrical conducted disturbance variables-

Test level 6-

Signals (test level 1)-

ECLASS 6.027049000

UNSPSC 13.239121004

Installation distance right/left-

Ambient temperature (start-up type tested)-40 °C

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-conden...

Input voltage range3x 320 V AC ... 575 V AC

Nominal input voltage range3x 400 V AC ... 500 V AC

Inrush current< 20 A (typical)

Type of protectionTransient surge protection

Setting range of the output voltage (USet)30 V DC ... 56 V DC (> 48 V ...

Derating60 °C ... 70 °C (2.5%/K)

Control deviation< 1 % (change in load, stati...

Power loss nominal load max.70 W

Insulation voltage output / PE500 V DC (routine test)

Conductor cross section flexible min.0.2 mm²

Conductor cross section flexible max.4 mm²

HART FSK Physical Layer Test Specification Compliance-

Standard - Safe isolationDIN VDE 0100-410

Rail applicationsEN 50121-4

Noise emission-

Input2 kV (Test Level 3 - symmetr...

Signal1 kV (Test Level 2 - asymmet...

Frequency-

Number of periods-

Test level 3-

Input, output (test level 3)-

Criterion BTemporary impairment to oper...

ECLASS 5.027242200

ETIM 7.0EC002540

UNSPSC 18.039121004

Power frequency magnetic field-

Damped oscillating magnetic field-

Test level 2-

Input, output (test level 1)-

Criterion ANormal operating behavior wi...

Criterion C-

UNSPSC 19.039121004

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

ECLASS 4.027040700

POWER BOOST (IBoost)22.5 A (-25 °C ... 40 °C per...

Active current limitationApprox. IBOOST = 22.5 A (for...

Housing materialSteel sheet, zinc-plated

ECLASS 4.127040700

ETIM 4.0EC002540

UNSPSC 12.0139121004

Standard - Approval for medical useIEC 60601-1, 2 x MOOP

ETIM 3.0EC001039

UNSPSC 6.0130211502

Standard - Equipment safetyBG (design tested)

Frequency range DC0 Hz

Screw threadM3

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178

UNSPSC 1139121004

UNSPSC 7.090139121004

About the manufacturer

Phoenix Contact

Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

About the Product Category

Devices for networking, which can be either hardware or software components, enable communication and data sharing among devices within a computer network. Their role is to create and sustain connectivity, improve the performance of the network, and safeguard data.

Data & Networking Devices

Relevant products

FAQ

Out if stock but available for backorder.

NearFi, base coupler for contactless power and Ethernet data transmission in real time over up to 10 mm, 24 V DC, 2 A, 100 Mbps full duplex, M12 fast-connection technology, IP65 degree of protection. A remote coupler is required for operation.

What can I help you find today?

Recommended parts