1234234 Phoenix Contact Data & Networking Devices

1234234 on Power Resources International
Phoenix Contact

Part#:1234234

Manufacturer:Phoenix Contact

Category:Data & Networking Devices

Product Lifecycle:Active

Product description

NearFi, remote coupler for contactless Ethernet data transmission in real time over up to 10 mm, 100 Mbps full duplex, M12 fast-connection technology, IP65 degree of protection. A base coupler is required for operation.

Product Details

  • Ambient temperature (operation)
    Tbd.
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Noise immunity
    Immunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial)
  • Net weight
    490 g
  • Width
    79 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Mounting type
    Wall mounting
  • Protective circuit
    Transient protection, polarity protection
  • Center offset
    ± 5 mm
  • Angular offset
    ± 7 °
  • Additional text
    RED 2014/53/EU
  • Contact discharge
    4 kV (Test Level 2)
  • Pollution degree
    1
  • ECLASS 9.0
    27040701
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Material
    PBT (Housing)
  • Connection method
    M12 female (D-coded)
  • Switch-on time
    ≤ 50 ms (Operational readiness time of the coupler system)
  • Delay time
    ≤ 3 µs (typical)
  • Test result
    10g
  • Voltage
    10 V (Test Level 3)
  • Height
    87 mm
  • Degree of protection
    IP65
  • Supply voltage range
    19 V DC ... 30 V DC
  • Transmission medium
    Copper
  • Transmission length
    100 m (shielded twisted pair)
  • Frequency range
    0.15 MHz ... 80 MHz
  • Identification
    CE-compliant
  • Type of test
    Continuous shock according to EN 60068-2-27/IEC 60068-2-27
  • Conducted noise emission
    EN 55016 EN 61000-6-4 Class A
  • Depth
    40 mm
  • Protection class
    II
  • Mounting position
    any
  • Interface 1
    Ethernet interface, 100Base-T(X) in accordance with IEEE 802.3
  • Operating mode
    full duplex
  • Transmission speed
    100 Mbps
  • Designation
    Wireless approval, Europe
  • Comments
    Criterion B
  • ECLASS 11.0
    27040701
  • Typical current consumption
    150 mA (at 24 V DC, at 25 °C)
  • No. of ports
    1
  • Range
    ≤ 10 mm
  • Wireless modules that can be connected
    1 (Base coupler)
  • Test field strength
    3 V/m (Test Level 2)
  • Standards/regulations
    EN 60204-1 (PELV)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 10.0.1
    27040701

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

1234234 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

Compare 1234234 with other products

Ambient temperature (oper...

Permissible humidity (ope...

Noise immunity

Net weight

Width

Ambient temperature (stor...

Mounting type

Protective circuit

Center offset

Angular offset

Additional text

Contact discharge

Pollution degree

ECLASS 9.0

Permissible humidity (sto...

Material

Connection method

Switch-on time

Delay time

Test result

Voltage

Height

Degree of protection

Supply voltage range

Transmission medium

Transmission length

Frequency range

Identification

Type of test

Conducted noise emission

Depth

Protection class

Mounting position

Interface 1

Operating mode

Transmission speed

Designation

Comments

ECLASS 11.0

Typical current consumpti...

No. of ports

Range

Wireless modules that can...

Test field strength

Standards/regulations

China RoHS

ECLASS 10.0.1

Ambient temperature (star...

Degree of pollution

Discharge current to PE

Mains buffering time

Protective circuit/compon...

Connection in parallel

Output power

MTBF (IEC 61709, SN 29500...

Insulation voltage output...

Conductor cross section s...

Conductor cross section A...

Standard – Electronic equ...

UL approvals

Input

Criterion B

ECLASS 4.0

Max. permissible relative...

Input voltage range

AC frequency range

REACh SVHC

Recommended breaker for i...

POWER BOOST (IBoost)

Connection in series

Active current limitation

Typical response time

Housing material

Assembly instructions

Standard - Safety of tran...

Standard – Limitation of ...

Electromagnetic HF field

Signal

Criterion A

ECLASS 4.1

ETIM 4.0

UNSPSC 12.01

Width with alternative as...

Installation height

Nominal power consumption

Nominal output current (I...

Selective Fuse Breaking (...

Protection against overvo...

Insulation voltage input ...

Conductor cross section f...

Stripping length

EMC requirements for nois...

Standard – Safety extra-l...

Standard - Approval for m...

CSA

Electrostatic discharge

Low Voltage Directive

Fast transients (burst)

Output

ECLASS 5.0

ETIM 3.0

ETIM 6.0

UNSPSC 6.01

UNSPSC 20.0

Height with alternative a...

Climatic class

Current consumption

Type of protection

Setting range of the outp...

Feedback voltage resistan...

Residual ripple

Power loss nominal load m...

Insulation voltage input/...

Conductor cross section A...

EMC requirements for nois...

Standard - Electrical saf...

Standard - Equipment safe...

Standard - Safe isolation

Electromagnetic compatibi...

Surge voltage load (surge...

Conducted interference

ECLASS 6.0

ETIM 7.0

UNSPSC 21.0

Depth with alternative as...

Nominal input voltage ran...

Frequency range DC

Inrush current

Nominal output voltage

Derating

Control deviation

Maximum power dissipation...

Efficiency

Conductor cross section s...

Conductor cross section f...

Screw thread

Standard – Protection aga...

Rail applications

Discharge in air

I/O/S

ECLASS 5.1

UNSPSC 11

UNSPSC 18.0

ECLASS 7.0

UNSPSC 7.0901

UNSPSC 13.2

UNSPSC 19.0

Environmental protection ...

Flicker

Installation distance top...

Dynamic Boost (IDyn.Boost...

Standard - safety for equ...

Mains variation/undervolt...

SIQ

DNV GL noise radiation

Voltage dips

Attenuated sinusoidal osc...

Test level 4

Attenuated oscillating wa...

Frequency range (fN)

Shipbuilding approval

Harmonic currents

Voltage dip

Test level 1

Test level 5

Input, output (test level...

Signals (test level 2)

Inflammability class in a...

Power factor (cos phi)

Static Boost (IStat.Boost...

EMC requirements, power p...

Standard - power supply d...

DNV GL conducted interfer...

Pulse-shape magnetic fiel...

Asymmetrical conducted di...

Test level 6

Signals (test level 1)

Installation distance rig...

HART FSK Physical Layer T...

Noise emission

Frequency

Number of periods

Test level 3

Input, output (test level...

Power frequency magnetic ...

Damped oscillating magnet...

Test level 2

Input, output (test level...

Criterion C

Selected product

1234234
0 in stock
1234234
Phoenix Contact

NearFi, remote coupler for contactless Ethernet data transmission in real time over up to 10 mm, 100...

Ambient temperature (operation)Tbd.

Permissible humidity (operation)5 % ... 95 % (non-condensing...

Noise immunityImmunity according to EN 610...

Net weight490 g

Width79 mm

Ambient temperature (storage/transport)-40 °C ... 85 °C

Mounting typeWall mounting

Protective circuitTransient protection, polari...

Center offset± 5 mm

Angular offset± 7 °

Additional textRED 2014/53/EU

Contact discharge4 kV (Test Level 2)

Pollution degree1

ECLASS 9.027040701

Permissible humidity (storage/transport)5 % ... 95 % (non-condensing...

MaterialPBT (Housing)

Connection methodM12 female (D-coded)

Switch-on time≤ 50 ms (Operational readine...

Delay time≤ 3 µs (typical)

Test result10g

Voltage10 V (Test Level 3)

Height87 mm

Degree of protectionIP65

Supply voltage range19 V DC ... 30 V DC

Transmission mediumCopper

Transmission length100 m (shielded twisted pair...

Frequency range0.15 MHz ... 80 MHz

IdentificationCE-compliant

Type of testContinuous shock according t...

Conducted noise emissionEN 55016 EN 61000-6-4 Class ...

Depth40 mm

Protection classII

Mounting positionany

Interface 1Ethernet interface, 100Base-...

Operating modefull duplex

Transmission speed100 Mbps

DesignationWireless approval, Europe

CommentsCriterion B

ECLASS 11.027040701

Typical current consumption150 mA (at 24 V DC, at 25 °C...

No. of ports1

Range≤ 10 mm

Wireless modules that can be connected1 (Base coupler)

Test field strength3 V/m (Test Level 2)

Standards/regulationsEN 60204-1 (PELV)

China RoHSEnvironmentally Friendly Use...

ECLASS 10.0.127040701

Ambient temperature (start-up type tested)-

Degree of pollution-

Discharge current to PE-

Mains buffering time-

Protective circuit/component-

Connection in parallel-

Output power-

MTBF (IEC 61709, SN 29500)-

Insulation voltage output / PE-

Conductor cross section solid min.-

Conductor cross section AWG max.-

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

UL approvals-

Input-

Criterion B-

ECLASS 4.0-

Max. permissible relative humidity (operation)-

Input voltage range-

AC frequency range-

REACh SVHC-

Recommended breaker for input protection-

POWER BOOST (IBoost)-

Connection in series-

Active current limitation-

Typical response time-

Housing material-

Assembly instructions-

Standard - Safety of transformers-

Standard – Limitation of mains harmonic currents-

Electromagnetic HF field-

Signal-

Criterion A-

ECLASS 4.1-

ETIM 4.0-

UNSPSC 12.01-

Width with alternative assembly-

Installation height-

Nominal power consumption-

Nominal output current (IN)-

Selective Fuse Breaking (ISFB)-

Protection against overvoltage at the output (OVP)-

Insulation voltage input / PE-

Conductor cross section flexible min.-

Stripping length-

EMC requirements for noise emission-

Standard – Safety extra-low voltage-

Standard - Approval for medical use-

CSA-

Electrostatic discharge-

Low Voltage Directive-

Fast transients (burst)-

Output-

ECLASS 5.0-

ETIM 3.0-

ETIM 6.0-

UNSPSC 6.01-

UNSPSC 20.0-

Height with alternative assembly-

Climatic class-

Current consumption-

Type of protection-

Setting range of the output voltage (USet)-

Feedback voltage resistance-

Residual ripple-

Power loss nominal load max.-

Insulation voltage input/output-

Conductor cross section AWG min.-

EMC requirements for noise immunity-

Standard - Electrical safety-

Standard - Equipment safety-

Standard - Safe isolation-

Electromagnetic compatibility-

Surge voltage load (surge)-

Conducted interference-

ECLASS 6.0-

ETIM 7.0-

UNSPSC 21.0-

Depth with alternative assembly-

Nominal input voltage range-

Frequency range DC-

Inrush current-

Nominal output voltage-

Derating-

Control deviation-

Maximum power dissipation in no-load condition-

Efficiency-

Conductor cross section solid max.-

Conductor cross section flexible max.-

Screw thread-

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-

Rail applications-

Discharge in air-

I/O/S-

ECLASS 5.1-

UNSPSC 11-

UNSPSC 18.0-

ECLASS 7.0-

UNSPSC 7.0901-

UNSPSC 13.2-

UNSPSC 19.0-

Environmental protection directive-

Flicker-

Installation distance top/bottom-

Dynamic Boost (IDyn.Boost)-

Standard - safety for equipment for measurement, control, and laboratory use-

Mains variation/undervoltage-

SIQ-

DNV GL noise radiation-

Voltage dips-

Attenuated sinusoidal oscillations (ring wave)-

Test level 4-

Attenuated oscillating wave-

Frequency range (fN)-

Shipbuilding approval-

Harmonic currents-

Voltage dip-

Test level 1-

Test level 5-

Input, output (test level 2)-

Signals (test level 2)-

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Power factor (cos phi)-

Static Boost (IStat.Boost)-

EMC requirements, power plant-

Standard - power supply devices for low voltage with DC output-

DNV GL conducted interference-

Pulse-shape magnetic field-

Asymmetrical conducted disturbance variables-

Test level 6-

Signals (test level 1)-

Installation distance right/left-

HART FSK Physical Layer Test Specification Compliance-

Noise emission-

Frequency-

Number of periods-

Test level 3-

Input, output (test level 3)-

Power frequency magnetic field-

Damped oscillating magnetic field-

Test level 2-

Input, output (test level 1)-

Criterion C-

2320827
3 in stock
2320827
Phoenix Contact

Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology...

Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C De...

Permissible humidity (operation)-

Noise immunity-

Net weight2.5 kg

Width96 mm

Ambient temperature (storage/transport)-40 °C ... 85 °C

Mounting type-

Protective circuit-

Center offset-

Angular offset-

Additional text-

Contact discharge8 kV (Test Level 4)

Pollution degree-

ECLASS 9.027040701

Permissible humidity (storage/transport)-

Material-

Connection methodScrew connection

Switch-on time-

Delay time-

Test result-

Voltage10 V (Test Level 3)

Height130 mm

Degree of protectionIP20

Supply voltage range-

Transmission medium-

Transmission length-

Frequency range0.15 MHz ... 80 MHz

Identification-

Type of test-

Conducted noise emission-

Depth179 mm

Protection classI

Mounting positionhorizontal DIN rail NS 35, E...

Interface 1-

Operating mode-

Transmission speed-

Designation-

CommentsCriterion A

ECLASS 11.027040701

Typical current consumption-

No. of ports-

Range-

Wireless modules that can be connected-

Test field strength10 V/m (Test Level 3)

Standards/regulations-

China RoHSEnvironmentally Friendly Use...

ECLASS 10.0.127040701

Ambient temperature (start-up type tested)-40 °C

Degree of pollution2

Discharge current to PE< 3.5 mA

Mains buffering timetyp. 25 ms (400 V AC)

Protective circuit/componentVaristor

Connection in parallelYes, for redundancy and incr...

Output power960 W

MTBF (IEC 61709, SN 29500)> 890000 h (25 °C)

Insulation voltage output / PE500 V DC (routine test)

Conductor cross section solid min.0.2 mm²

Conductor cross section AWG max.10

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

UL approvalsUL Listed UL 508

Input2 kV (Test Level 3 - symmetr...

Criterion BTemporary impairment to oper...

ECLASS 4.027040700

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-conden...

Input voltage range3x 320 V AC ... 575 V AC

AC frequency range45 Hz ... 65 Hz

REACh SVHCLead 7439-92-1

Recommended breaker for input protection6 A ... 16 A (AC: Characteri...

POWER BOOST (IBoost)22.5 A (-25 °C ... 40 °C per...

Connection in seriesyes

Active current limitationApprox. IBOOST = 22.5 A (for...

Typical response time< 1 s

Housing materialSteel sheet, zinc-plated

Assembly instructionsalignable: PN ≥50%, 5 mm hor...

Standard - Safety of transformersIEC 61558-2-17

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Electromagnetic HF fieldEN 61000-4-3

Signal1 kV (Test Level 2 - asymmet...

Criterion ANormal operating behavior wi...

ECLASS 4.127040700

ETIM 4.0EC002540

UNSPSC 12.0139121004

Width with alternative assembly176 mm

Installation height4000 m

Nominal power consumption1386 VA

Nominal output current (IN)20 A (-25 °C ... 60 °C, UOUT...

Selective Fuse Breaking (ISFB)100 A (12 ms)

Protection against overvoltage at the output (OVP)< 60 V DC

Insulation voltage input / PE3.5 kV AC (type test)

Conductor cross section flexible min.0.2 mm²

Stripping length10 mm

EMC requirements for noise emissionEN 61000-6-3

Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60...

Standard - Approval for medical useIEC 60601-1, 2 x MOOP

CSACAN/CSA-C22.2 No. 60950-1-07

Electrostatic dischargeEN 61000-4-2

Low Voltage DirectiveConformance with Low Voltage...

Fast transients (burst)EN 61000-4-4

Output1 kV (Test Level 2 - symmetr...

ECLASS 5.027242200

ETIM 3.0EC001039

ETIM 6.0EC002540

UNSPSC 6.0130211502

UNSPSC 20.039121004

Height with alternative assembly130 mm

Climatic class3K3 (in acc. with EN 60721)

Current consumption3x 2.1 A (400 V AC)

Type of protectionTransient surge protection

Setting range of the output voltage (USet)30 V DC ... 56 V DC (> 48 V ...

Feedback voltage resistancemax. 60 V DC

Residual ripple< 50 mVPP (with nominal valu...

Power loss nominal load max.70 W

Insulation voltage input/output4 kV AC (type test)

Conductor cross section AWG min.18

EMC requirements for noise immunityEN 61000-6-1

Standard - Electrical safetyIEC 60950-1/VDE 0805 (SELV)

Standard - Equipment safetyBG (design tested)

Standard - Safe isolationDIN VDE 0100-410

Electromagnetic compatibilityConformance with EMC Directi...

Surge voltage load (surge)EN 61000-4-5

Conducted interferenceEN 61000-4-6

ECLASS 6.027049000

ETIM 7.0EC002540

UNSPSC 21.039121004

Depth with alternative assembly99 mm

Nominal input voltage range3x 400 V AC ... 500 V AC

Frequency range DC0 Hz

Inrush current< 20 A (typical)

Nominal output voltage48 V DC ±1 %

Derating60 °C ... 70 °C (2.5%/K)

Control deviation< 1 % (change in load, stati...

Maximum power dissipation in no-load condition24 W

Efficiency> 93 % (at 400 V AC and nomi...

Conductor cross section solid max.6 mm²

Conductor cross section flexible max.4 mm²

Screw threadM3

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178

Rail applicationsEN 50121-4

Discharge in air15 kV (Test Level 4)

I/O/Sasymmetrical

ECLASS 5.127242200

UNSPSC 1139121004

UNSPSC 18.039121004

ECLASS 7.027049002

UNSPSC 7.090139121004

UNSPSC 13.239121004

UNSPSC 19.039121004

Environmental protection directive-

Flicker-

Installation distance top/bottom-

Dynamic Boost (IDyn.Boost)-

Standard - safety for equipment for measurement, control, and laboratory use-

Mains variation/undervoltage-

SIQ-

DNV GL noise radiation-

Voltage dips-

Attenuated sinusoidal oscillations (ring wave)-

Test level 4-

Attenuated oscillating wave-

Frequency range (fN)-

Shipbuilding approval-

Harmonic currents-

Voltage dip-

Test level 1-

Test level 5-

Input, output (test level 2)-

Signals (test level 2)-

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Power factor (cos phi)-

Static Boost (IStat.Boost)-

EMC requirements, power plant-

Standard - power supply devices for low voltage with DC output-

DNV GL conducted interference-

Pulse-shape magnetic field-

Asymmetrical conducted disturbance variables-

Test level 6-

Signals (test level 1)-

Installation distance right/left-

HART FSK Physical Layer Test Specification Compliance-

Noise emission-

Frequency-

Number of periods-

Test level 3-

Input, output (test level 3)-

Power frequency magnetic field-

Damped oscillating magnetic field-

Test level 2-

Input, output (test level 1)-

Criterion C-

2904622
17 in stock
2904622
Phoenix Contact

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (sele...

Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C De...

Permissible humidity (operation)-

Noise immunity-

Net weight1.1 kg

Width70 mm

Ambient temperature (storage/transport)-40 °C ... 85 °C

Mounting type-

Protective circuit-

Center offset-

Angular offset-

Additional textTest Level 2

Contact discharge8 kV (Test Level 4)

Pollution degree-

ECLASS 9.027040701

Permissible humidity (storage/transport)-

Material-

Connection methodPush-in connection

Switch-on time-

Delay time-

Test result-

Voltage2.5 kV

Height130 mm

Degree of protectionIP20

Supply voltage range-

Transmission medium-

Transmission length-

Frequency range50 Hz ... 60 Hz

Identification-

Type of test-

Conducted noise emissionEN 55016

Depth125 mm

Protection classI

Mounting positionhorizontal DIN rail NS 35, E...

Interface 1-

Operating mode-

Transmission speed-

Designation-

CommentsCriterion A

ECLASS 11.027040701

Typical current consumption-

No. of ports-

Range-

Wireless modules that can be connected-

Test field strength110 A/m

Standards/regulations-

China RoHSEnvironmentally Friendly Use...

ECLASS 10.0.127040701

Ambient temperature (start-up type tested)-40 °C

Degree of pollution2

Discharge current to PE< 3.5 mA

Mains buffering timetyp. 33 ms (3x 400 V AC)

Protective circuit/componentVaristor, gas-filled surge a...

Connection in parallelYes, for redundancy and incr...

Output power480 W

MTBF (IEC 61709, SN 29500)> 985000 h (25 °C)

Insulation voltage output / PE0.5 kV DC (type test)

Conductor cross section solid min.0.2 mm²

Conductor cross section AWG max.16

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

UL approvalsUL Listed UL 508

Input2 kV (Test Level 4 - symmetr...

Criterion BTemporary impairment to oper...

ECLASS 4.0-

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-conden...

Input voltage range3x 400 V AC ... 500 V AC -20...

AC frequency range50 Hz ... 60 Hz -10 % ... +1...

REACh SVHCLead 7439-92-1

Recommended breaker for input protection3x 4 A ... 20 A (Characteris...

POWER BOOST (IBoost)-

Connection in seriesyes

Active current limitation-

Typical response time300 ms (from SLEEP MODE)

Housing material-

Assembly instructionsalignable: PN ≥50%, 5 mm hor...

Standard - Safety of transformersIEC 61558-2-16 pending

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Electromagnetic HF fieldEN 61000-4-3

Signal1 kV (Test Level 2 - asymmet...

Criterion ANormal operating behavior wi...

ECLASS 4.1-

ETIM 4.0-

UNSPSC 12.01-

Width with alternative assembly122 mm

Installation height≤ 5000 m (> 2000 m, observe ...

Nominal power consumption541 VA

Nominal output current (IN)20 A

Selective Fuse Breaking (ISFB)120 A (15 ms)

Protection against overvoltage at the output (OVP)≤ 32 V DC

Insulation voltage input / PE3.5 kV AC (type test)

Conductor cross section flexible min.0.2 mm²

Stripping length8 mm

EMC requirements for noise emissionEN 61000-6-3

Standard – Safety extra-low voltageIEC 61010-1 (SELV)

Standard - Approval for medical use-

CSACAN/CSA-C22.2 No. 60950-1-07

Electrostatic dischargeEN 61000-4-2

Low Voltage DirectiveConformance with Low Voltage...

Fast transients (burst)EN 61000-4-4

Output1 kV (Test Level 3 - symmetr...

ECLASS 5.027242200

ETIM 3.0-

ETIM 6.0EC002540

UNSPSC 6.01-

UNSPSC 20.039121004

Height with alternative assembly130 mm

Climatic class3K3 (in acc. with EN 60721)

Current consumption3x 0.99 A (400 V AC)

Type of protectionTransient surge protection

Setting range of the output voltage (USet)24 V DC ... 29.5 V DC (const...

Feedback voltage resistance≤ 35 V DC

Residual ripple< 60 mVPP (with nominal valu...

Power loss nominal load max.< 32 W (400 V AC)

Insulation voltage input/output4 kV AC (type test)

Conductor cross section AWG min.24

EMC requirements for noise immunityEN 61000-6-1

Standard - Electrical safetyIEC 61010-2-201 (SELV)

Standard - Equipment safety-

Standard - Safe isolationIEC 61558-2-16 pending

Electromagnetic compatibilityConformance with EMC Directi...

Surge voltage load (surge)EN 61000-4-5

Conducted interferenceEN 61000-4-6

ECLASS 6.027049000

ETIM 7.0EC002540

UNSPSC 21.039121004

Depth with alternative assembly73 mm

Nominal input voltage range3x 400 V AC ... 500 V AC

Frequency range DC-

Inrush currenttyp. 2 A (at 25 °C)

Nominal output voltage24 V DC

Derating> 60 °C ... 70 °C (2.5%/K)

Control deviation< 0.5 % (Static load change ...

Maximum power dissipation in no-load condition< 7 W (400 V AC)

Efficiencytyp. 93.9 % (400 V AC)

Conductor cross section solid max.1 mm²

Conductor cross section flexible max.1.5 mm²

Screw thread-

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-

Rail applicationsEN 50121-3-2

Discharge in air15 kV (Test Level 4)

I/O/Sasymmetrical

ECLASS 5.127242200

UNSPSC 11-

UNSPSC 18.039121004

ECLASS 7.027049002

UNSPSC 7.0901-

UNSPSC 13.239121004

UNSPSC 19.039121004

Environmental protection directiveRoHS Directive 2011/65/EU

FlickerEN 61000-3-3

Installation distance top/bottom50 mm / 50 mm

Dynamic Boost (IDyn.Boost)30 A (5 s)

Standard - safety for equipment for measurement, control, and laboratory useIEC 61010-1

Mains variation/undervoltageSEMI F47-0706, EN 61000-4-11

SIQBG (type approved)

DNV GL noise radiationClass B

Voltage dipsEN 61000-4-11

Attenuated sinusoidal oscillations (ring wave)EN 61000-4-12

Test level 415 kHz 150 kHz (Test Level 4...

Attenuated oscillating waveEN 61000-4-18

Frequency range (fN)50 Hz ... 60 Hz -10 % ... +1...

Shipbuilding approvalDNV GL, PRS, BV, LR, ABS

Harmonic currentsEN 61000-3-2

Voltage dip0 %

Test level 115 Hz 150 Hz (Test Level 4)

Test level 516.7 Hz 50 Hz 60 Hz (Test Le...

Input, output (test level 2)10 MHz

Signals (test level 2)100 kHz 1 MHz (Test Level 3 ...

Inflammability class in acc. with UL 94 (housing / terminal blocks)V0

Power factor (cos phi)0.94

Static Boost (IStat.Boost)25 A

EMC requirements, power plantIEC 61850-3

Standard - power supply devices for low voltage with DC outputEN 61204-3

DNV GL conducted interferenceClass A

Pulse-shape magnetic fieldEN 61000-4-9

Asymmetrical conducted disturbance variablesEN 61000-4-16

Test level 616.7 Hz 50 Hz 60 Hz (Test Le...

Signals (test level 1)100 kHz 1 MHz (Test Level 3 ...

Installation distance right/left5 mm / 5 mm

HART FSK Physical Layer Test Specification ComplianceOutput voltage UOut complian...

Noise emissionEN 55016

Frequency50 Hz

Number of periods0,5 / 1 / 5 / 50 / 250 perio...

Test level 31.5 kHz 15 kHz (Test Level 4...

Input, output (test level 3)100 kHz 1 MHz (Test Level 3 ...

Power frequency magnetic fieldEN 61000-4-8

Damped oscillating magnetic fieldEN 61000-4-10

Test level 2150 Hz 1.5 kHz (Test Level 4...

Input, output (test level 1)100 kHz 1 MHz (Test Level 3 ...

Criterion CTemporary adverse effects on...

About the manufacturer

Phoenix Contact

Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

About the Product Category

Devices for networking, which can be either hardware or software components, enable communication and data sharing among devices within a computer network. Their role is to create and sustain connectivity, improve the performance of the network, and safeguard data.

Data & Networking Devices

Relevant products

FAQ

Out if stock but available for backorder.

NearFi, remote coupler for contactless Ethernet data transmission in real time over up to 10 mm, 100 Mbps full duplex, M12 fast-connection technology, IP65 degree of protection. A base coupler is required for operation.

What can I help you find today?

Recommended parts