1234226 Phoenix Contact Data & Networking Devices

1234226 on Power Resources International
Phoenix Contact

Part#:1234226

Manufacturer:Phoenix Contact

Category:Data & Networking Devices

Product Lifecycle:Active

Product description

NearFi, base coupler for contactless power transmission over up to 10 mm, 24 V DC, 2 A, M12 fast-connection technology, IP65 degree of protection. A remote coupler is required for operation.

Product Details

  • Net weight
    490 g
  • Width
    79 mm
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Depth
    40 mm
  • Degree of protection
    IP65
  • Mounting type
    Wall mounting
  • Switch-on time
    ≤ 1 s (Operational readiness time of the coupler system, power polling)
  • Protective circuit
    Transient protection, polarity protection
  • Frequency range
    0.15 MHz ... 80 MHz
  • Output name
    Digital output
  • Number of inputs
    1
  • Switching level "1" signal
    19 V DC ... 30 V DC
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Noise immunity
    Immunity according to EN 61000-6-1 (residential), EN 61000-6-2 (industrial)
  • Typical current consumption
    20 mA (without remote, at 24 V DC, at 25°C)
  • Range
    ≤ 10 mm
  • Angular offset
    ± 7 °
  • Number of outputs
    1
  • Current output signal
    25 mA
  • Voltage input signal
    19 V DC ... 30 V DC
  • Designation
    Wireless approval, Europe
  • Contact discharge
    4 kV (Test Level 2)
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 9.0
    27040701
  • Ambient temperature (operation)
    Tbd.
  • Mounting position
    any
  • Connection method
    M12 connector, (A-coded)
  • Operating mode
    Power Polling (default setting)
  • Contact type
    Open collector output, external pull-up resistor
  • Description of the input
    Digital input
  • Additional text
    RED 2014/53/EU
  • Type of test
    Continuous shock according to EN 60068-2-27/IEC 60068-2-27
  • Standards/regulations
    EN 60204-1 (PELV)
  • Test field strength
    3 V/m (Test Level 2)
  • ECLASS 11.0
    27040701
  • Height
    87 mm
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Protection class
    II
  • Material
    PBT (Housing)
  • Supply voltage range
    19 V DC ... 30 V DC
  • Pollution degree
    1
  • Conducted noise emission
    EN 55016 EN 61000-6-4 Class A
  • Center offset
    ± 5 mm
  • Efficiency
    ≤ 90 %
  • Voltage output signal
    19 V DC ... 30 V DC (depending on the operating voltage)
  • Test result
    10g
  • Identification
    CE-compliant
  • Comments
    Criterion B
  • Voltage
    10 V (Test Level 3)
  • ECLASS 10.0.1
    27040701

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

1234226 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

Compare 1234226 with other products

Net weight

Width

Permissible humidity (sto...

Depth

Degree of protection

Mounting type

Switch-on time

Protective circuit

Frequency range

Output name

Number of inputs

Switching level "1" signa...

Permissible humidity (ope...

Noise immunity

Typical current consumpti...

Range

Angular offset

Number of outputs

Current output signal

Voltage input signal

Designation

Contact discharge

China RoHS

ECLASS 9.0

Ambient temperature (oper...

Mounting position

Connection method

Operating mode

Contact type

Description of the input

Additional text

Type of test

Standards/regulations

Test field strength

ECLASS 11.0

Height

Ambient temperature (stor...

Protection class

Material

Supply voltage range

Pollution degree

Conducted noise emission

Center offset

Efficiency

Voltage output signal

Test result

Identification

Comments

Voltage

ECLASS 10.0.1

Ambient temperature (star...

Degree of pollution

Discharge current to PE

Mains buffering time

Protective circuit/compon...

Connection in parallel

Output power

MTBF (IEC 61709, SN 29500...

Insulation voltage output...

Conductor cross section s...

Conductor cross section A...

Standard – Electronic equ...

UL approvals

Input

Criterion B

ECLASS 4.0

Max. permissible relative...

Input voltage range

AC frequency range

REACh SVHC

Recommended breaker for i...

POWER BOOST (IBoost)

Connection in series

Active current limitation

Typical response time

Housing material

Assembly instructions

Standard - Safety of tran...

Standard – Limitation of ...

Electromagnetic HF field

Signal

Criterion A

ECLASS 4.1

ETIM 4.0

UNSPSC 12.01

Width with alternative as...

Installation height

Nominal power consumption

Nominal output current (I...

Selective Fuse Breaking (...

Protection against overvo...

Insulation voltage input ...

Conductor cross section f...

Stripping length

EMC requirements for nois...

Standard – Safety extra-l...

Standard - Approval for m...

CSA

Electrostatic discharge

Low Voltage Directive

Fast transients (burst)

Output

ECLASS 5.0

ETIM 3.0

ETIM 6.0

UNSPSC 6.01

UNSPSC 20.0

Height with alternative a...

Climatic class

Current consumption

Type of protection

Setting range of the outp...

Feedback voltage resistan...

Residual ripple

Power loss nominal load m...

Insulation voltage input/...

Conductor cross section A...

EMC requirements for nois...

Standard - Electrical saf...

Standard - Equipment safe...

Standard - Safe isolation

Electromagnetic compatibi...

Surge voltage load (surge...

Conducted interference

ECLASS 6.0

ETIM 7.0

UNSPSC 21.0

Depth with alternative as...

Nominal input voltage ran...

Frequency range DC

Inrush current

Nominal output voltage

Derating

Control deviation

Maximum power dissipation...

Conductor cross section s...

Conductor cross section f...

Screw thread

Standard – Protection aga...

Rail applications

Discharge in air

I/O/S

ECLASS 5.1

UNSPSC 11

UNSPSC 18.0

ECLASS 7.0

UNSPSC 7.0901

UNSPSC 13.2

UNSPSC 19.0

Environmental protection ...

Flicker

Installation distance top...

Dynamic Boost (IDyn.Boost...

Standard - safety for equ...

Mains variation/undervolt...

SIQ

DNV GL noise radiation

Voltage dips

Attenuated sinusoidal osc...

Test level 4

Attenuated oscillating wa...

Frequency range (fN)

Shipbuilding approval

Harmonic currents

Voltage dip

Test level 1

Test level 5

Input, output (test level...

Signals (test level 2)

Inflammability class in a...

Power factor (cos phi)

Static Boost (IStat.Boost...

EMC requirements, power p...

Standard - power supply d...

DNV GL conducted interfer...

Pulse-shape magnetic fiel...

Asymmetrical conducted di...

Test level 6

Signals (test level 1)

Installation distance rig...

HART FSK Physical Layer T...

Noise emission

Frequency

Number of periods

Test level 3

Input, output (test level...

Power frequency magnetic ...

Damped oscillating magnet...

Test level 2

Input, output (test level...

Criterion C

Selected product

1234226
0 in stock
1234226
Phoenix Contact

NearFi, base coupler for contactless power transmission over up to 10 mm, 24 V DC, 2 A, M12 fast-con...

Net weight490 g

Width79 mm

Permissible humidity (storage/transport)5 % ... 95 % (non-condensing...

Depth40 mm

Degree of protectionIP65

Mounting typeWall mounting

Switch-on time≤ 1 s (Operational readiness...

Protective circuitTransient protection, polari...

Frequency range0.15 MHz ... 80 MHz

Output nameDigital output

Number of inputs1

Switching level "1" signal19 V DC ... 30 V DC

Permissible humidity (operation)5 % ... 95 % (non-condensing...

Noise immunityImmunity according to EN 610...

Typical current consumption20 mA (without remote, at 24...

Range≤ 10 mm

Angular offset± 7 °

Number of outputs1

Current output signal25 mA

Voltage input signal19 V DC ... 30 V DC

DesignationWireless approval, Europe

Contact discharge4 kV (Test Level 2)

China RoHSEnvironmentally Friendly Use...

ECLASS 9.027040701

Ambient temperature (operation)Tbd.

Mounting positionany

Connection methodM12 connector, (A-coded)

Operating modePower Polling (default setti...

Contact typeOpen collector output, exter...

Description of the inputDigital input

Additional textRED 2014/53/EU

Type of testContinuous shock according t...

Standards/regulationsEN 60204-1 (PELV)

Test field strength3 V/m (Test Level 2)

ECLASS 11.027040701

Height87 mm

Ambient temperature (storage/transport)-40 °C ... 85 °C

Protection classII

MaterialPBT (Housing)

Supply voltage range19 V DC ... 30 V DC

Pollution degree1

Conducted noise emissionEN 55016 EN 61000-6-4 Class ...

Center offset± 5 mm

Efficiency≤ 90 %

Voltage output signal19 V DC ... 30 V DC (dependi...

Test result10g

IdentificationCE-compliant

CommentsCriterion B

Voltage10 V (Test Level 3)

ECLASS 10.0.127040701

Ambient temperature (start-up type tested)-

Degree of pollution-

Discharge current to PE-

Mains buffering time-

Protective circuit/component-

Connection in parallel-

Output power-

MTBF (IEC 61709, SN 29500)-

Insulation voltage output / PE-

Conductor cross section solid min.-

Conductor cross section AWG max.-

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

UL approvals-

Input-

Criterion B-

ECLASS 4.0-

Max. permissible relative humidity (operation)-

Input voltage range-

AC frequency range-

REACh SVHC-

Recommended breaker for input protection-

POWER BOOST (IBoost)-

Connection in series-

Active current limitation-

Typical response time-

Housing material-

Assembly instructions-

Standard - Safety of transformers-

Standard – Limitation of mains harmonic currents-

Electromagnetic HF field-

Signal-

Criterion A-

ECLASS 4.1-

ETIM 4.0-

UNSPSC 12.01-

Width with alternative assembly-

Installation height-

Nominal power consumption-

Nominal output current (IN)-

Selective Fuse Breaking (ISFB)-

Protection against overvoltage at the output (OVP)-

Insulation voltage input / PE-

Conductor cross section flexible min.-

Stripping length-

EMC requirements for noise emission-

Standard – Safety extra-low voltage-

Standard - Approval for medical use-

CSA-

Electrostatic discharge-

Low Voltage Directive-

Fast transients (burst)-

Output-

ECLASS 5.0-

ETIM 3.0-

ETIM 6.0-

UNSPSC 6.01-

UNSPSC 20.0-

Height with alternative assembly-

Climatic class-

Current consumption-

Type of protection-

Setting range of the output voltage (USet)-

Feedback voltage resistance-

Residual ripple-

Power loss nominal load max.-

Insulation voltage input/output-

Conductor cross section AWG min.-

EMC requirements for noise immunity-

Standard - Electrical safety-

Standard - Equipment safety-

Standard - Safe isolation-

Electromagnetic compatibility-

Surge voltage load (surge)-

Conducted interference-

ECLASS 6.0-

ETIM 7.0-

UNSPSC 21.0-

Depth with alternative assembly-

Nominal input voltage range-

Frequency range DC-

Inrush current-

Nominal output voltage-

Derating-

Control deviation-

Maximum power dissipation in no-load condition-

Conductor cross section solid max.-

Conductor cross section flexible max.-

Screw thread-

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-

Rail applications-

Discharge in air-

I/O/S-

ECLASS 5.1-

UNSPSC 11-

UNSPSC 18.0-

ECLASS 7.0-

UNSPSC 7.0901-

UNSPSC 13.2-

UNSPSC 19.0-

Environmental protection directive-

Flicker-

Installation distance top/bottom-

Dynamic Boost (IDyn.Boost)-

Standard - safety for equipment for measurement, control, and laboratory use-

Mains variation/undervoltage-

SIQ-

DNV GL noise radiation-

Voltage dips-

Attenuated sinusoidal oscillations (ring wave)-

Test level 4-

Attenuated oscillating wave-

Frequency range (fN)-

Shipbuilding approval-

Harmonic currents-

Voltage dip-

Test level 1-

Test level 5-

Input, output (test level 2)-

Signals (test level 2)-

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Power factor (cos phi)-

Static Boost (IStat.Boost)-

EMC requirements, power plant-

Standard - power supply devices for low voltage with DC output-

DNV GL conducted interference-

Pulse-shape magnetic field-

Asymmetrical conducted disturbance variables-

Test level 6-

Signals (test level 1)-

Installation distance right/left-

HART FSK Physical Layer Test Specification Compliance-

Noise emission-

Frequency-

Number of periods-

Test level 3-

Input, output (test level 3)-

Power frequency magnetic field-

Damped oscillating magnetic field-

Test level 2-

Input, output (test level 1)-

Criterion C-

2320827
3 in stock
2320827
Phoenix Contact

Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology...

Net weight2.5 kg

Width96 mm

Permissible humidity (storage/transport)-

Depth179 mm

Degree of protectionIP20

Mounting type-

Switch-on time-

Protective circuit-

Frequency range0.15 MHz ... 80 MHz

Output name-

Number of inputs-

Switching level "1" signal-

Permissible humidity (operation)-

Noise immunity-

Typical current consumption-

Range-

Angular offset-

Number of outputs-

Current output signal-

Voltage input signal-

Designation-

Contact discharge8 kV (Test Level 4)

China RoHSEnvironmentally Friendly Use...

ECLASS 9.027040701

Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C De...

Mounting positionhorizontal DIN rail NS 35, E...

Connection methodScrew connection

Operating mode-

Contact type-

Description of the input-

Additional text-

Type of test-

Standards/regulations-

Test field strength10 V/m (Test Level 3)

ECLASS 11.027040701

Height130 mm

Ambient temperature (storage/transport)-40 °C ... 85 °C

Protection classI

Material-

Supply voltage range-

Pollution degree-

Conducted noise emission-

Center offset-

Efficiency> 93 % (at 400 V AC and nomi...

Voltage output signal-

Test result-

Identification-

CommentsCriterion A

Voltage10 V (Test Level 3)

ECLASS 10.0.127040701

Ambient temperature (start-up type tested)-40 °C

Degree of pollution2

Discharge current to PE< 3.5 mA

Mains buffering timetyp. 25 ms (400 V AC)

Protective circuit/componentVaristor

Connection in parallelYes, for redundancy and incr...

Output power960 W

MTBF (IEC 61709, SN 29500)> 890000 h (25 °C)

Insulation voltage output / PE500 V DC (routine test)

Conductor cross section solid min.0.2 mm²

Conductor cross section AWG max.10

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

UL approvalsUL Listed UL 508

Input2 kV (Test Level 3 - symmetr...

Criterion BTemporary impairment to oper...

ECLASS 4.027040700

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-conden...

Input voltage range3x 320 V AC ... 575 V AC

AC frequency range45 Hz ... 65 Hz

REACh SVHCLead 7439-92-1

Recommended breaker for input protection6 A ... 16 A (AC: Characteri...

POWER BOOST (IBoost)22.5 A (-25 °C ... 40 °C per...

Connection in seriesyes

Active current limitationApprox. IBOOST = 22.5 A (for...

Typical response time< 1 s

Housing materialSteel sheet, zinc-plated

Assembly instructionsalignable: PN ≥50%, 5 mm hor...

Standard - Safety of transformersIEC 61558-2-17

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Electromagnetic HF fieldEN 61000-4-3

Signal1 kV (Test Level 2 - asymmet...

Criterion ANormal operating behavior wi...

ECLASS 4.127040700

ETIM 4.0EC002540

UNSPSC 12.0139121004

Width with alternative assembly176 mm

Installation height4000 m

Nominal power consumption1386 VA

Nominal output current (IN)20 A (-25 °C ... 60 °C, UOUT...

Selective Fuse Breaking (ISFB)100 A (12 ms)

Protection against overvoltage at the output (OVP)< 60 V DC

Insulation voltage input / PE3.5 kV AC (type test)

Conductor cross section flexible min.0.2 mm²

Stripping length10 mm

EMC requirements for noise emissionEN 61000-6-3

Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60...

Standard - Approval for medical useIEC 60601-1, 2 x MOOP

CSACAN/CSA-C22.2 No. 60950-1-07

Electrostatic dischargeEN 61000-4-2

Low Voltage DirectiveConformance with Low Voltage...

Fast transients (burst)EN 61000-4-4

Output1 kV (Test Level 2 - symmetr...

ECLASS 5.027242200

ETIM 3.0EC001039

ETIM 6.0EC002540

UNSPSC 6.0130211502

UNSPSC 20.039121004

Height with alternative assembly130 mm

Climatic class3K3 (in acc. with EN 60721)

Current consumption3x 2.1 A (400 V AC)

Type of protectionTransient surge protection

Setting range of the output voltage (USet)30 V DC ... 56 V DC (> 48 V ...

Feedback voltage resistancemax. 60 V DC

Residual ripple< 50 mVPP (with nominal valu...

Power loss nominal load max.70 W

Insulation voltage input/output4 kV AC (type test)

Conductor cross section AWG min.18

EMC requirements for noise immunityEN 61000-6-1

Standard - Electrical safetyIEC 60950-1/VDE 0805 (SELV)

Standard - Equipment safetyBG (design tested)

Standard - Safe isolationDIN VDE 0100-410

Electromagnetic compatibilityConformance with EMC Directi...

Surge voltage load (surge)EN 61000-4-5

Conducted interferenceEN 61000-4-6

ECLASS 6.027049000

ETIM 7.0EC002540

UNSPSC 21.039121004

Depth with alternative assembly99 mm

Nominal input voltage range3x 400 V AC ... 500 V AC

Frequency range DC0 Hz

Inrush current< 20 A (typical)

Nominal output voltage48 V DC ±1 %

Derating60 °C ... 70 °C (2.5%/K)

Control deviation< 1 % (change in load, stati...

Maximum power dissipation in no-load condition24 W

Conductor cross section solid max.6 mm²

Conductor cross section flexible max.4 mm²

Screw threadM3

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178

Rail applicationsEN 50121-4

Discharge in air15 kV (Test Level 4)

I/O/Sasymmetrical

ECLASS 5.127242200

UNSPSC 1139121004

UNSPSC 18.039121004

ECLASS 7.027049002

UNSPSC 7.090139121004

UNSPSC 13.239121004

UNSPSC 19.039121004

Environmental protection directive-

Flicker-

Installation distance top/bottom-

Dynamic Boost (IDyn.Boost)-

Standard - safety for equipment for measurement, control, and laboratory use-

Mains variation/undervoltage-

SIQ-

DNV GL noise radiation-

Voltage dips-

Attenuated sinusoidal oscillations (ring wave)-

Test level 4-

Attenuated oscillating wave-

Frequency range (fN)-

Shipbuilding approval-

Harmonic currents-

Voltage dip-

Test level 1-

Test level 5-

Input, output (test level 2)-

Signals (test level 2)-

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Power factor (cos phi)-

Static Boost (IStat.Boost)-

EMC requirements, power plant-

Standard - power supply devices for low voltage with DC output-

DNV GL conducted interference-

Pulse-shape magnetic field-

Asymmetrical conducted disturbance variables-

Test level 6-

Signals (test level 1)-

Installation distance right/left-

HART FSK Physical Layer Test Specification Compliance-

Noise emission-

Frequency-

Number of periods-

Test level 3-

Input, output (test level 3)-

Power frequency magnetic field-

Damped oscillating magnetic field-

Test level 2-

Input, output (test level 1)-

Criterion C-

2904622
17 in stock
2904622
Phoenix Contact

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (sele...

Net weight1.1 kg

Width70 mm

Permissible humidity (storage/transport)-

Depth125 mm

Degree of protectionIP20

Mounting type-

Switch-on time-

Protective circuit-

Frequency range50 Hz ... 60 Hz

Output name-

Number of inputs-

Switching level "1" signal-

Permissible humidity (operation)-

Noise immunity-

Typical current consumption-

Range-

Angular offset-

Number of outputs-

Current output signal-

Voltage input signal-

Designation-

Contact discharge8 kV (Test Level 4)

China RoHSEnvironmentally Friendly Use...

ECLASS 9.027040701

Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C De...

Mounting positionhorizontal DIN rail NS 35, E...

Connection methodPush-in connection

Operating mode-

Contact type-

Description of the input-

Additional textTest Level 2

Type of test-

Standards/regulations-

Test field strength110 A/m

ECLASS 11.027040701

Height130 mm

Ambient temperature (storage/transport)-40 °C ... 85 °C

Protection classI

Material-

Supply voltage range-

Pollution degree-

Conducted noise emissionEN 55016

Center offset-

Efficiencytyp. 93.9 % (400 V AC)

Voltage output signal-

Test result-

Identification-

CommentsCriterion A

Voltage2.5 kV

ECLASS 10.0.127040701

Ambient temperature (start-up type tested)-40 °C

Degree of pollution2

Discharge current to PE< 3.5 mA

Mains buffering timetyp. 33 ms (3x 400 V AC)

Protective circuit/componentVaristor, gas-filled surge a...

Connection in parallelYes, for redundancy and incr...

Output power480 W

MTBF (IEC 61709, SN 29500)> 985000 h (25 °C)

Insulation voltage output / PE0.5 kV DC (type test)

Conductor cross section solid min.0.2 mm²

Conductor cross section AWG max.16

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

UL approvalsUL Listed UL 508

Input2 kV (Test Level 4 - symmetr...

Criterion BTemporary impairment to oper...

ECLASS 4.0-

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-conden...

Input voltage range3x 400 V AC ... 500 V AC -20...

AC frequency range50 Hz ... 60 Hz -10 % ... +1...

REACh SVHCLead 7439-92-1

Recommended breaker for input protection3x 4 A ... 20 A (Characteris...

POWER BOOST (IBoost)-

Connection in seriesyes

Active current limitation-

Typical response time300 ms (from SLEEP MODE)

Housing material-

Assembly instructionsalignable: PN ≥50%, 5 mm hor...

Standard - Safety of transformersIEC 61558-2-16 pending

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Electromagnetic HF fieldEN 61000-4-3

Signal1 kV (Test Level 2 - asymmet...

Criterion ANormal operating behavior wi...

ECLASS 4.1-

ETIM 4.0-

UNSPSC 12.01-

Width with alternative assembly122 mm

Installation height≤ 5000 m (> 2000 m, observe ...

Nominal power consumption541 VA

Nominal output current (IN)20 A

Selective Fuse Breaking (ISFB)120 A (15 ms)

Protection against overvoltage at the output (OVP)≤ 32 V DC

Insulation voltage input / PE3.5 kV AC (type test)

Conductor cross section flexible min.0.2 mm²

Stripping length8 mm

EMC requirements for noise emissionEN 61000-6-3

Standard – Safety extra-low voltageIEC 61010-1 (SELV)

Standard - Approval for medical use-

CSACAN/CSA-C22.2 No. 60950-1-07

Electrostatic dischargeEN 61000-4-2

Low Voltage DirectiveConformance with Low Voltage...

Fast transients (burst)EN 61000-4-4

Output1 kV (Test Level 3 - symmetr...

ECLASS 5.027242200

ETIM 3.0-

ETIM 6.0EC002540

UNSPSC 6.01-

UNSPSC 20.039121004

Height with alternative assembly130 mm

Climatic class3K3 (in acc. with EN 60721)

Current consumption3x 0.99 A (400 V AC)

Type of protectionTransient surge protection

Setting range of the output voltage (USet)24 V DC ... 29.5 V DC (const...

Feedback voltage resistance≤ 35 V DC

Residual ripple< 60 mVPP (with nominal valu...

Power loss nominal load max.< 32 W (400 V AC)

Insulation voltage input/output4 kV AC (type test)

Conductor cross section AWG min.24

EMC requirements for noise immunityEN 61000-6-1

Standard - Electrical safetyIEC 61010-2-201 (SELV)

Standard - Equipment safety-

Standard - Safe isolationIEC 61558-2-16 pending

Electromagnetic compatibilityConformance with EMC Directi...

Surge voltage load (surge)EN 61000-4-5

Conducted interferenceEN 61000-4-6

ECLASS 6.027049000

ETIM 7.0EC002540

UNSPSC 21.039121004

Depth with alternative assembly73 mm

Nominal input voltage range3x 400 V AC ... 500 V AC

Frequency range DC-

Inrush currenttyp. 2 A (at 25 °C)

Nominal output voltage24 V DC

Derating> 60 °C ... 70 °C (2.5%/K)

Control deviation< 0.5 % (Static load change ...

Maximum power dissipation in no-load condition< 7 W (400 V AC)

Conductor cross section solid max.1 mm²

Conductor cross section flexible max.1.5 mm²

Screw thread-

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-

Rail applicationsEN 50121-3-2

Discharge in air15 kV (Test Level 4)

I/O/Sasymmetrical

ECLASS 5.127242200

UNSPSC 11-

UNSPSC 18.039121004

ECLASS 7.027049002

UNSPSC 7.0901-

UNSPSC 13.239121004

UNSPSC 19.039121004

Environmental protection directiveRoHS Directive 2011/65/EU

FlickerEN 61000-3-3

Installation distance top/bottom50 mm / 50 mm

Dynamic Boost (IDyn.Boost)30 A (5 s)

Standard - safety for equipment for measurement, control, and laboratory useIEC 61010-1

Mains variation/undervoltageSEMI F47-0706, EN 61000-4-11

SIQBG (type approved)

DNV GL noise radiationClass B

Voltage dipsEN 61000-4-11

Attenuated sinusoidal oscillations (ring wave)EN 61000-4-12

Test level 415 kHz 150 kHz (Test Level 4...

Attenuated oscillating waveEN 61000-4-18

Frequency range (fN)50 Hz ... 60 Hz -10 % ... +1...

Shipbuilding approvalDNV GL, PRS, BV, LR, ABS

Harmonic currentsEN 61000-3-2

Voltage dip0 %

Test level 115 Hz 150 Hz (Test Level 4)

Test level 516.7 Hz 50 Hz 60 Hz (Test Le...

Input, output (test level 2)10 MHz

Signals (test level 2)100 kHz 1 MHz (Test Level 3 ...

Inflammability class in acc. with UL 94 (housing / terminal blocks)V0

Power factor (cos phi)0.94

Static Boost (IStat.Boost)25 A

EMC requirements, power plantIEC 61850-3

Standard - power supply devices for low voltage with DC outputEN 61204-3

DNV GL conducted interferenceClass A

Pulse-shape magnetic fieldEN 61000-4-9

Asymmetrical conducted disturbance variablesEN 61000-4-16

Test level 616.7 Hz 50 Hz 60 Hz (Test Le...

Signals (test level 1)100 kHz 1 MHz (Test Level 3 ...

Installation distance right/left5 mm / 5 mm

HART FSK Physical Layer Test Specification ComplianceOutput voltage UOut complian...

Noise emissionEN 55016

Frequency50 Hz

Number of periods0,5 / 1 / 5 / 50 / 250 perio...

Test level 31.5 kHz 15 kHz (Test Level 4...

Input, output (test level 3)100 kHz 1 MHz (Test Level 3 ...

Power frequency magnetic fieldEN 61000-4-8

Damped oscillating magnetic fieldEN 61000-4-10

Test level 2150 Hz 1.5 kHz (Test Level 4...

Input, output (test level 1)100 kHz 1 MHz (Test Level 3 ...

Criterion CTemporary adverse effects on...

About the manufacturer

Phoenix Contact

Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

About the Product Category

Devices for networking, which can be either hardware or software components, enable communication and data sharing among devices within a computer network. Their role is to create and sustain connectivity, improve the performance of the network, and safeguard data.

Data & Networking Devices

Relevant products

FAQ

Out if stock but available for backorder.

NearFi, base coupler for contactless power transmission over up to 10 mm, 24 V DC, 2 A, M12 fast-connection technology, IP65 degree of protection. A remote coupler is required for operation.

What can I help you find today?

Recommended parts