2316372 Phoenix Contact Data & Networking Devices

2316372 on Power Resources International
Phoenix Contact

Part#:2316372

Manufacturer:Phoenix Contact

Category:Data & Networking Devices

Product Lifecycle:Active

Product description

Head station for basic system functionality, no monitoring of PROFIBUS networks

Product Details

  • Height
    100 mm
  • Net weight
    222 g
  • Conductor cross section flexible max.
    2.5 mm²
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • UL, USA/Canada
    UL 508 Listed
  • Conductor cross section solid min.
    0.2 mm²
  • Standards/regulations
    IEC 61158-2
  • ECLASS 10.0.1
    27242610
  • UNSPSC 19.0
    32151602
  • Ambient temperature (operation)
    -20 °C ... 60 °C
  • Mounting type
    DIN rail: 35 mm
  • Color
    green
  • Max. current consumption
    800 mA
  • Conductor cross section flexible min.
    0.2 mm²
  • No. of ports
    1
  • Designation
    PROFIBUS standardization
  • ECLASS 7.0
    27242610
  • ECLASS 5.1
    27242200
  • UNSPSC 13.2
    32151602
  • UNSPSC 21.0
    32151602
  • Depth
    132 mm
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • UL, Canada
    CSA C22.2 No. 142
  • Conductor cross section solid max.
    2.5 mm²
  • Conductor cross section AWG min.
    24
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.0
    27242200
  • ECLASS 9.0
    27242610
  • UNSPSC 18.0
    32151602
  • Ambient temperature (storage/transport)
    -20 °C ... 60 °C
  • Degree of protection
    IP20
  • Supply voltage range
    10.8 V DC ... 26.4 V DC
  • Conductor cross section AWG max.
    12
  • Interface
    10/100 Mbps Ethernet
  • Connection method
    RJ45
  • ECLASS 6.0
    27242600
  • ETIM 7.0
    EC001600
  • Width
    25 mm
  • UNSPSC 20.0
    32151602
  • Interface 1
    Ethernet
  • ECLASS 11.0
    27242610
  • ETIM 6.0
    EC001600

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

2316372 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

Compare 2316372 with other products

Height

Net weight

Conductor cross section f...

Permissible humidity (ope...

UL, USA/Canada

Conductor cross section s...

Standards/regulations

ECLASS 10.0.1

UNSPSC 19.0

Ambient temperature (oper...

Mounting type

Color

Max. current consumption

Conductor cross section f...

No. of ports

Designation

ECLASS 7.0

ECLASS 5.1

UNSPSC 13.2

UNSPSC 21.0

Depth

Permissible humidity (sto...

UL, Canada

Conductor cross section s...

Conductor cross section A...

China RoHS

ECLASS 5.0

ECLASS 9.0

UNSPSC 18.0

Ambient temperature (stor...

Degree of protection

Supply voltage range

Conductor cross section A...

Interface

Connection method

ECLASS 6.0

ETIM 7.0

Width

UNSPSC 20.0

Interface 1

ECLASS 11.0

ETIM 6.0

Max. permissible relative...

Nominal power consumption

Mains buffering time

Protective circuit/compon...

Feedback voltage resistan...

Output power

Inflammability class in a...

Climatic class

Input voltage range

Inrush current

Type of protection

Installation distance top...

Nominal input voltage ran...

Frequency range (fN)

Input fuse

Power factor (cos phi)

Connection in parallel

Residual ripple

Control deviation

Efficiency

Standard – Safety extra-l...

Discharge in air

Comments

Surge voltage load (surge...

Voltage dips

UNSPSC 11

Installation distance rig...

Degree of pollution

Current consumption

Recommended breaker for i...

Nominal output current (I...

Nominal output voltage

Connection in series

Protection class

Assembly instructions

Screw thread

Standard - Safety of tran...

Standard – Limitation of ...

Electromagnetic compatibi...

Contact discharge

Input

Criterion A

ECLASS 4.0

ETIM 3.0

UNSPSC 12.01

MTBF (IEC 61709, SN 29500...

Foot latch material

Mounting position

EMC requirements for nois...

Standard – Electronic equ...

CSA

Fast transients (burst)

Electromagnetic HF field

Output

UNSPSC 7.0901

Derating

Typical response time

Housing material

EMC requirements for nois...

Standard - Safe isolation

Criterion B

ECLASS 4.1

ETIM 4.0

Power loss nominal load m...

Stripping length

Low Voltage Directive

Test field strength

Voltage

Conducted interference

UNSPSC 6.01

Insulation voltage input/...

Standard - Electrical saf...

Frequency range

Protection against overvo...

Maximum power dissipation...

Mains variation/undervolt...

UL approvals

Electrostatic discharge

Width with alternative as...

AC frequency range

Environmental protection ...

Flicker

I/O/S

Dynamic Boost (IDyn.Boost...

Selective Fuse Breaking (...

Standard - safety for equ...

SIQ

DNV GL noise radiation

Attenuated sinusoidal osc...

Test level 4

Attenuated oscillating wa...

REACh SVHC

Depth with alternative as...

Installation height

Shipbuilding approval

Harmonic currents

Voltage dip

Test level 1

Test level 5

Input, output (test level...

Signals (test level 2)

Height with alternative a...

Discharge current to PE

Static Boost (IStat.Boost...

Insulation voltage input ...

EMC requirements, power p...

Standard - power supply d...

Conducted noise emission

DNV GL conducted interfer...

Pulse-shape magnetic fiel...

Asymmetrical conducted di...

Test level 6

Signals (test level 1)

Ambient temperature (star...

Setting range of the outp...

Insulation voltage output...

HART FSK Physical Layer T...

Rail applications

Noise emission

Additional text

Signal

Frequency

Number of periods

Test level 3

Input, output (test level...

Power frequency magnetic ...

Damped oscillating magnet...

Test level 2

Input, output (test level...

Criterion C

Selected product

2316372
0 in stock
2316372
Phoenix Contact

Head station for basic system functionality, no monitoring of PROFIBUS networks

Height100 mm

Net weight222 g

Conductor cross section flexible max.2.5 mm²

Permissible humidity (operation)5 % ... 95 % (non-condensing...

UL, USA/CanadaUL 508 Listed

Conductor cross section solid min.0.2 mm²

Standards/regulationsIEC 61158-2

ECLASS 10.0.127242610

UNSPSC 19.032151602

Ambient temperature (operation)-20 °C ... 60 °C

Mounting typeDIN rail: 35 mm

Colorgreen

Max. current consumption800 mA

Conductor cross section flexible min.0.2 mm²

No. of ports1

DesignationPROFIBUS standardization

ECLASS 7.027242610

ECLASS 5.127242200

UNSPSC 13.232151602

UNSPSC 21.032151602

Depth132 mm

Permissible humidity (storage/transport)5 % ... 95 % (non-condensing...

UL, CanadaCSA C22.2 No. 142

Conductor cross section solid max.2.5 mm²

Conductor cross section AWG min.24

China RoHSEnvironmentally Friendly Use...

ECLASS 5.027242200

ECLASS 9.027242610

UNSPSC 18.032151602

Ambient temperature (storage/transport)-20 °C ... 60 °C

Degree of protectionIP20

Supply voltage range10.8 V DC ... 26.4 V DC

Conductor cross section AWG max.12

Interface10/100 Mbps Ethernet

Connection methodRJ45

ECLASS 6.027242600

ETIM 7.0EC001600

Width25 mm

UNSPSC 20.032151602

Interface 1Ethernet

ECLASS 11.027242610

ETIM 6.0EC001600

Max. permissible relative humidity (operation)-

Nominal power consumption-

Mains buffering time-

Protective circuit/component-

Feedback voltage resistance-

Output power-

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Climatic class-

Input voltage range-

Inrush current-

Type of protection-

Installation distance top/bottom-

Nominal input voltage range-

Frequency range (fN)-

Input fuse-

Power factor (cos phi)-

Connection in parallel-

Residual ripple-

Control deviation-

Efficiency-

Standard – Safety extra-low voltage-

Discharge in air-

Comments-

Surge voltage load (surge)-

Voltage dips-

UNSPSC 11-

Installation distance right/left-

Degree of pollution-

Current consumption-

Recommended breaker for input protection-

Nominal output current (IN)-

Nominal output voltage-

Connection in series-

Protection class-

Assembly instructions-

Screw thread-

Standard - Safety of transformers-

Standard – Limitation of mains harmonic currents-

Electromagnetic compatibility-

Contact discharge-

Input-

Criterion A-

ECLASS 4.0-

ETIM 3.0-

UNSPSC 12.01-

MTBF (IEC 61709, SN 29500)-

Foot latch material-

Mounting position-

EMC requirements for noise immunity-

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

CSA-

Fast transients (burst)-

Electromagnetic HF field-

Output-

UNSPSC 7.0901-

Derating-

Typical response time-

Housing material-

EMC requirements for noise emission-

Standard - Safe isolation-

Criterion B-

ECLASS 4.1-

ETIM 4.0-

Power loss nominal load max.-

Stripping length-

Low Voltage Directive-

Test field strength-

Voltage-

Conducted interference-

UNSPSC 6.01-

Insulation voltage input/output-

Standard - Electrical safety-

Frequency range-

Protection against overvoltage at the output (OVP)-

Maximum power dissipation in no-load condition-

Mains variation/undervoltage-

UL approvals-

Electrostatic discharge-

Width with alternative assembly-

AC frequency range-

Environmental protection directive-

Flicker-

I/O/S-

Dynamic Boost (IDyn.Boost)-

Selective Fuse Breaking (ISFB)-

Standard - safety for equipment for measurement, control, and laboratory use-

SIQ-

DNV GL noise radiation-

Attenuated sinusoidal oscillations (ring wave)-

Test level 4-

Attenuated oscillating wave-

REACh SVHC-

Depth with alternative assembly-

Installation height-

Shipbuilding approval-

Harmonic currents-

Voltage dip-

Test level 1-

Test level 5-

Input, output (test level 2)-

Signals (test level 2)-

Height with alternative assembly-

Discharge current to PE-

Static Boost (IStat.Boost)-

Insulation voltage input / PE-

EMC requirements, power plant-

Standard - power supply devices for low voltage with DC output-

Conducted noise emission-

DNV GL conducted interference-

Pulse-shape magnetic field-

Asymmetrical conducted disturbance variables-

Test level 6-

Signals (test level 1)-

Ambient temperature (start-up type tested)-

Setting range of the output voltage (USet)-

Insulation voltage output / PE-

HART FSK Physical Layer Test Specification Compliance-

Rail applications-

Noise emission-

Additional text-

Signal-

Frequency-

Number of periods-

Test level 3-

Input, output (test level 3)-

Power frequency magnetic field-

Damped oscillating magnetic field-

Test level 2-

Input, output (test level 1)-

Criterion C-

2903002
56 in stock
2903002
Phoenix Contact

Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 15 V DC/100 W

Height90 mm

Net weight0.34 kg

Conductor cross section flexible max.2.5 mm²

Permissible humidity (operation)-

UL, USA/Canada-

Conductor cross section solid min.0.2 mm²

Standards/regulations-

ECLASS 10.0.127040701

UNSPSC 19.039121004

Ambient temperature (operation)-25 °C ... 70 °C (> 55 °C De...

Mounting type-

Color-

Max. current consumption-

Conductor cross section flexible min.0.2 mm²

No. of ports-

Designation-

ECLASS 7.027049002

ECLASS 5.127049000

UNSPSC 13.239121004

UNSPSC 21.039121004

Depth84 mm

Permissible humidity (storage/transport)-

UL, Canada-

Conductor cross section solid max.2.5 mm²

Conductor cross section AWG min.24

China RoHSEnvironmentally Friendly Use...

ECLASS 5.027049000

ECLASS 9.027040701

UNSPSC 18.039121004

Ambient temperature (storage/transport)-40 °C ... 85 °C

Degree of protectionIP20

Supply voltage range-

Conductor cross section AWG max.14

Interface-

Connection methodScrew connection

ECLASS 6.027049000

ETIM 7.0EC002540

Width55 mm

UNSPSC 20.039121004

Interface 1-

ECLASS 11.027040701

ETIM 6.0EC002540

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-conden...

Nominal power consumption206.3 VA

Mains buffering time> 20 ms (120 V AC)

Protective circuit/componentVaristor

Feedback voltage resistance< 25 V DC

Output power100 W

Inflammability class in acc. with UL 94 (housing / terminal blocks)V0

Climatic class3K3 (in acc. with EN 60721)

Input voltage range85 V AC ... 264 V AC

Inrush current< 30 A (typical)

Type of protectionTransient surge protection

Installation distance top/bottom30 mm / 30 mm

Nominal input voltage range100 V AC ... 240 V AC

Frequency range (fN)50 Hz ... 60 Hz 10 %

Input fuse4 A (slow-blow, internal)

Power factor (cos phi)0.54

Connection in parallelYes, for redundancy and incr...

Residual ripple< 75 mVPP (with nominal valu...

Control deviation< 1 % (change in load, stati...

Efficiencytyp. 89 % (120 V AC)

Standard – Safety extra-low voltageIEC 62368-1 (SELV) und EN 60...

Discharge in air8 kV (Test Level 3)

CommentsCriterion A

Surge voltage load (surge)EN 61000-4-5

Voltage dipsEN 61000-4-11

UNSPSC 1139121004

Installation distance right/left0 mm / 0 mm

Degree of pollution2

Current consumption2.19 A (100 V AC)

Recommended breaker for input protection6 A ... 16 A (Characteristic...

Nominal output current (IN)6.67 A (-25 °C ... 55 °C)

Nominal output voltage15 V DC ±1 %

Connection in seriesyes

Protection classII (in closed control cabine...

Assembly instructionsalignable: 0 mm horizontally...

Screw threadM3

Standard - Safety of transformersEN 61558-2-16

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Electromagnetic compatibilityConformance with EMC Directi...

Contact discharge6 kV (Test Level 3)

Input2 kV (Test Level 3 - symmetr...

Criterion ANormal operating behavior wi...

ECLASS 4.027040700

ETIM 3.0EC001039

UNSPSC 12.0139121004

MTBF (IEC 61709, SN 29500)> 727000 h (40 °C)

Foot latch materialPOM (Polyoxymethylen)

Mounting positionhorizontal DIN rail NS 35, E...

EMC requirements for noise immunityEN 61000-6-1

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

CSACAN/CSA-C22.2 No. 60950-1-07

Fast transients (burst)EN 61000-4-4

Electromagnetic HF fieldEN 61000-4-3

Output1 kV (Test Level 2 - symmetr...

UNSPSC 7.090139121004

Derating55 °C ... 70 °C (2.5%/K)

Typical response time< 1 s

Housing materialPolycarbonate

EMC requirements for noise emissionEN 61000-6-3

Standard - Safe isolationDIN VDE 0100-410

Criterion BTemporary impairment to oper...

ECLASS 4.127040700

ETIM 4.0EC000599

Power loss nominal load max.< 12 W

Stripping length8 mm

Low Voltage DirectiveConformance with Low Voltage...

Test field strength10 V/m

Voltage10 V (Test Level 3)

Conducted interferenceEN 61000-4-6

UNSPSC 6.0130211502

Insulation voltage input/output4 kV AC (type test)

Standard - Electrical safetyIEC 62368-1/VDE 0805 (SELV)

Frequency range10 kHz ... 80 MHz

Protection against overvoltage at the output (OVP)≤ 25 V DC

Maximum power dissipation in no-load condition< 0.4 W

Mains variation/undervoltageEN 61000-4-11

UL approvalsUL/C-UL listed UL 508

Electrostatic dischargeEN 61000-4-2

Width with alternative assembly-

AC frequency range-

Environmental protection directive-

Flicker-

I/O/S-

Dynamic Boost (IDyn.Boost)-

Selective Fuse Breaking (ISFB)-

Standard - safety for equipment for measurement, control, and laboratory use-

SIQ-

DNV GL noise radiation-

Attenuated sinusoidal oscillations (ring wave)-

Test level 4-

Attenuated oscillating wave-

REACh SVHC-

Depth with alternative assembly-

Installation height-

Shipbuilding approval-

Harmonic currents-

Voltage dip-

Test level 1-

Test level 5-

Input, output (test level 2)-

Signals (test level 2)-

Height with alternative assembly-

Discharge current to PE-

Static Boost (IStat.Boost)-

Insulation voltage input / PE-

EMC requirements, power plant-

Standard - power supply devices for low voltage with DC output-

Conducted noise emission-

DNV GL conducted interference-

Pulse-shape magnetic field-

Asymmetrical conducted disturbance variables-

Test level 6-

Signals (test level 1)-

Ambient temperature (start-up type tested)-

Setting range of the output voltage (USet)-

Insulation voltage output / PE-

HART FSK Physical Layer Test Specification Compliance-

Rail applications-

Noise emission-

Additional text-

Signal-

Frequency-

Number of periods-

Test level 3-

Input, output (test level 3)-

Power frequency magnetic field-

Damped oscillating magnetic field-

Test level 2-

Input, output (test level 1)-

Criterion C-

2904622
17 in stock
2904622
Phoenix Contact

Primary-switched QUINT POWER power supply with free choice of output characteristic curve, SFB (sele...

Height130 mm

Net weight1.1 kg

Conductor cross section flexible max.1.5 mm²

Permissible humidity (operation)-

UL, USA/Canada-

Conductor cross section solid min.0.2 mm²

Standards/regulations-

ECLASS 10.0.127040701

UNSPSC 19.039121004

Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C De...

Mounting type-

Color-

Max. current consumption-

Conductor cross section flexible min.0.2 mm²

No. of ports-

Designation-

ECLASS 7.027049002

ECLASS 5.127242200

UNSPSC 13.239121004

UNSPSC 21.039121004

Depth125 mm

Permissible humidity (storage/transport)-

UL, Canada-

Conductor cross section solid max.1 mm²

Conductor cross section AWG min.24

China RoHSEnvironmentally Friendly Use...

ECLASS 5.027242200

ECLASS 9.027040701

UNSPSC 18.039121004

Ambient temperature (storage/transport)-40 °C ... 85 °C

Degree of protectionIP20

Supply voltage range-

Conductor cross section AWG max.16

Interface-

Connection methodPush-in connection

ECLASS 6.027049000

ETIM 7.0EC002540

Width70 mm

UNSPSC 20.039121004

Interface 1-

ECLASS 11.027040701

ETIM 6.0EC002540

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-conden...

Nominal power consumption541 VA

Mains buffering timetyp. 33 ms (3x 400 V AC)

Protective circuit/componentVaristor, gas-filled surge a...

Feedback voltage resistance≤ 35 V DC

Output power480 W

Inflammability class in acc. with UL 94 (housing / terminal blocks)V0

Climatic class3K3 (in acc. with EN 60721)

Input voltage range3x 400 V AC ... 500 V AC -20...

Inrush currenttyp. 2 A (at 25 °C)

Type of protectionTransient surge protection

Installation distance top/bottom50 mm / 50 mm

Nominal input voltage range3x 400 V AC ... 500 V AC

Frequency range (fN)50 Hz ... 60 Hz -10 % ... +1...

Input fuse-

Power factor (cos phi)0.94

Connection in parallelYes, for redundancy and incr...

Residual ripple< 60 mVPP (with nominal valu...

Control deviation< 0.5 % (Static load change ...

Efficiencytyp. 93.9 % (400 V AC)

Standard – Safety extra-low voltageIEC 61010-1 (SELV)

Discharge in air15 kV (Test Level 4)

CommentsCriterion A

Surge voltage load (surge)EN 61000-4-5

Voltage dipsEN 61000-4-11

UNSPSC 11-

Installation distance right/left5 mm / 5 mm

Degree of pollution2

Current consumption3x 0.99 A (400 V AC)

Recommended breaker for input protection3x 4 A ... 20 A (Characteris...

Nominal output current (IN)20 A

Nominal output voltage24 V DC

Connection in seriesyes

Protection classI

Assembly instructionsalignable: PN ≥50%, 5 mm hor...

Screw thread-

Standard - Safety of transformersIEC 61558-2-16 pending

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Electromagnetic compatibilityConformance with EMC Directi...

Contact discharge8 kV (Test Level 4)

Input2 kV (Test Level 4 - symmetr...

Criterion ANormal operating behavior wi...

ECLASS 4.0-

ETIM 3.0-

UNSPSC 12.01-

MTBF (IEC 61709, SN 29500)> 985000 h (25 °C)

Foot latch material-

Mounting positionhorizontal DIN rail NS 35, E...

EMC requirements for noise immunityEN 61000-6-1

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

CSACAN/CSA-C22.2 No. 60950-1-07

Fast transients (burst)EN 61000-4-4

Electromagnetic HF fieldEN 61000-4-3

Output1 kV (Test Level 3 - symmetr...

UNSPSC 7.0901-

Derating> 60 °C ... 70 °C (2.5%/K)

Typical response time300 ms (from SLEEP MODE)

Housing material-

EMC requirements for noise emissionEN 61000-6-3

Standard - Safe isolationIEC 61558-2-16 pending

Criterion BTemporary impairment to oper...

ECLASS 4.1-

ETIM 4.0-

Power loss nominal load max.< 32 W (400 V AC)

Stripping length8 mm

Low Voltage DirectiveConformance with Low Voltage...

Test field strength110 A/m

Voltage2.5 kV

Conducted interferenceEN 61000-4-6

UNSPSC 6.01-

Insulation voltage input/output4 kV AC (type test)

Standard - Electrical safetyIEC 61010-2-201 (SELV)

Frequency range50 Hz ... 60 Hz

Protection against overvoltage at the output (OVP)≤ 32 V DC

Maximum power dissipation in no-load condition< 7 W (400 V AC)

Mains variation/undervoltageSEMI F47-0706, EN 61000-4-11

UL approvalsUL Listed UL 508

Electrostatic dischargeEN 61000-4-2

Width with alternative assembly122 mm

AC frequency range50 Hz ... 60 Hz -10 % ... +1...

Environmental protection directiveRoHS Directive 2011/65/EU

FlickerEN 61000-3-3

I/O/Sasymmetrical

Dynamic Boost (IDyn.Boost)30 A (5 s)

Selective Fuse Breaking (ISFB)120 A (15 ms)

Standard - safety for equipment for measurement, control, and laboratory useIEC 61010-1

SIQBG (type approved)

DNV GL noise radiationClass B

Attenuated sinusoidal oscillations (ring wave)EN 61000-4-12

Test level 415 kHz 150 kHz (Test Level 4...

Attenuated oscillating waveEN 61000-4-18

REACh SVHCLead 7439-92-1

Depth with alternative assembly73 mm

Installation height≤ 5000 m (> 2000 m, observe ...

Shipbuilding approvalDNV GL, PRS, BV, LR, ABS

Harmonic currentsEN 61000-3-2

Voltage dip0 %

Test level 115 Hz 150 Hz (Test Level 4)

Test level 516.7 Hz 50 Hz 60 Hz (Test Le...

Input, output (test level 2)10 MHz

Signals (test level 2)100 kHz 1 MHz (Test Level 3 ...

Height with alternative assembly130 mm

Discharge current to PE< 3.5 mA

Static Boost (IStat.Boost)25 A

Insulation voltage input / PE3.5 kV AC (type test)

EMC requirements, power plantIEC 61850-3

Standard - power supply devices for low voltage with DC outputEN 61204-3

Conducted noise emissionEN 55016

DNV GL conducted interferenceClass A

Pulse-shape magnetic fieldEN 61000-4-9

Asymmetrical conducted disturbance variablesEN 61000-4-16

Test level 616.7 Hz 50 Hz 60 Hz (Test Le...

Signals (test level 1)100 kHz 1 MHz (Test Level 3 ...

Ambient temperature (start-up type tested)-40 °C

Setting range of the output voltage (USet)24 V DC ... 29.5 V DC (const...

Insulation voltage output / PE0.5 kV DC (type test)

HART FSK Physical Layer Test Specification ComplianceOutput voltage UOut complian...

Rail applicationsEN 50121-3-2

Noise emissionEN 55016

Additional textTest Level 2

Signal1 kV (Test Level 2 - asymmet...

Frequency50 Hz

Number of periods0,5 / 1 / 5 / 50 / 250 perio...

Test level 31.5 kHz 15 kHz (Test Level 4...

Input, output (test level 3)100 kHz 1 MHz (Test Level 3 ...

Power frequency magnetic fieldEN 61000-4-8

Damped oscillating magnetic fieldEN 61000-4-10

Test level 2150 Hz 1.5 kHz (Test Level 4...

Input, output (test level 1)100 kHz 1 MHz (Test Level 3 ...

Criterion CTemporary adverse effects on...

About the manufacturer

Phoenix Contact

Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

About the Product Category

Devices for networking, which can be either hardware or software components, enable communication and data sharing among devices within a computer network. Their role is to create and sustain connectivity, improve the performance of the network, and safeguard data.

Data & Networking Devices

Relevant products

FAQ

Out if stock but available for backorder.

Head station for basic system functionality, no monitoring of PROFIBUS networks

What can I help you find today?

Recommended parts