2316420 Phoenix Contact Data & Networking Devices

2316420 on Power Resources International
Phoenix Contact

Part#:2316420

Manufacturer:Phoenix Contact

Category:Data & Networking Devices

Product Lifecycle:Active

Product description

Stainless steel field junction box with ten ports for use in hazardous locations. Includes six-spur block device coupler (FB-6SP) for Foundation Fieldbus or PROFIBUS PA, three terminal blocks for trunk cable connection (+, –, S).

Product Details

  • Depth
    127 mm
  • Color
    gray
  • Max. output voltage Uo
    Uin (spur)
  • Additional text
    per spur
  • Max. output power Po
    1.792 W
  • UL, USA/Canada
    Class I, Zone 2, AEx nA [ic] IIC T4 Gc, AEx nA nC[ic] IIC T4 Gc Entity/FISCO spursClass I, Div. 2, Groups A, B, C, D, T4Class I, Zone 22, AEx tc IIIC T135 Dc IP66
  • Height
    254 mm
  • Degree of protection
    IP66
  • Housing material
    Stainless steel
  • Max. external inductivity Lo
    0.26 mH
  • Safety-related maximum voltage Um
    17.5 V (in acc. with EN 60079-11)
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27250203
  • ECLASS 5.1
    27259205
  • Ambient temperature (operation)
    -40 °C ... 70 °C
  • Net weight
    4640 g
  • Max. current consumption
    4.8 mA (No-load)
  • Max. external capacitance Co
    80 nF
  • ECLASS 10.0.1
    27180101
  • ECLASS 5.0
    27250203
  • Utilization restriction
    Use in potentially explosive areas is not permitted in China.
  • Ambient temperature (storage/transport)
    -40 °C ... 70 °C
  • Conformance
    CE-compliant, additionally EN 61326-1
  • Mounting type
    Wall mounting
  • Inductance Li
    4 µH
  • ETIM 3.0
    EC001600
  • ETIM 6.0
    EC000261
  • UNSPSC 13.2
    43201553
  • Width
    254 mm
  • ATEX
    DEMKO 16ATEX1704X II 3 G DEx nA [ic] IIC T4 Gc, Ex nA nC [ic] IIC T4 GcEx ic IIC T4 Gc, FISCO ic spursEx tc IIIC T135 Dc IP66
  • ECLASS 6.0
    27180100
  • ECLASS 7.0
    27180101
  • UNSPSC 12.01
    39121008
  • Input voltage Ui
    32 V (IIB (C/D))
  • Max. output current Io
    56 mA (spur)
  • IECEx
    IECEx UL 16.0079XEx nA [ic] IIC T4 Gc, Ex nA nC [ic] IIC T4 GcEx ic IIC T4 Gc, FISCO ic spursEx tc IIIC T135 Dc IP66
  • ECLASS 4.0
    27250203
  • ECLASS 9.0
    27180101
  • UNSPSC 6.01
    30211506
  • ECLASS 11.0
    27180101
  • ETIM 7.0
    EC000261
  • UNSPSC 7.0901
    39121008
  • Group
    IIC/IIB
  • Standards/regulations
    EN 61326-1
  • ETIM 4.0
    EC000261
  • UNSPSC 11
    39121008

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

2316420 Phoenix Contact

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

Compare 2316420 with other products

Depth

Color

Max. output voltage Uo

Additional text

Max. output power Po

UL, USA/Canada

Height

Degree of protection

Housing material

Max. external inductivity...

Safety-related maximum vo...

REACh SVHC

ECLASS 4.1

ECLASS 5.1

Ambient temperature (oper...

Net weight

Max. current consumption

Max. external capacitance...

ECLASS 10.0.1

ECLASS 5.0

Utilization restriction

Ambient temperature (stor...

Conformance

Mounting type

Inductance Li

ETIM 3.0

ETIM 6.0

UNSPSC 13.2

Width

ATEX

ECLASS 6.0

ECLASS 7.0

UNSPSC 12.01

Input voltage Ui

Max. output current Io

IECEx

ECLASS 4.0

ECLASS 9.0

UNSPSC 6.01

ECLASS 11.0

ETIM 7.0

UNSPSC 7.0901

Group

Standards/regulations

ETIM 4.0

UNSPSC 11

Ambient temperature (star...

Degree of pollution

Discharge current to PE

Mains buffering time

Protective circuit/compon...

Connection in parallel

Output power

MTBF (IEC 61709, SN 29500...

Insulation voltage output...

Conductor cross section s...

Conductor cross section A...

Standard – Electronic equ...

UL approvals

Contact discharge

Test field strength

Input

Criterion B

Max. permissible relative...

Input voltage range

AC frequency range

Recommended breaker for i...

POWER BOOST (IBoost)

Connection in series

Active current limitation

Typical response time

Assembly instructions

Connection method

Standard - Safety of tran...

Standard – Limitation of ...

Electromagnetic HF field

Signal

Criterion A

Width with alternative as...

Installation height

Nominal power consumption

Nominal output current (I...

Selective Fuse Breaking (...

Protection against overvo...

Insulation voltage input ...

Mounting position

Conductor cross section f...

Stripping length

EMC requirements for nois...

Standard – Safety extra-l...

Standard - Approval for m...

CSA

Electrostatic discharge

Low Voltage Directive

Fast transients (burst)

Output

Voltage

China RoHS

UNSPSC 20.0

Height with alternative a...

Climatic class

Current consumption

Type of protection

Setting range of the outp...

Feedback voltage resistan...

Residual ripple

Power loss nominal load m...

Insulation voltage input/...

Protection class

Conductor cross section A...

EMC requirements for nois...

Standard - Electrical saf...

Standard - Equipment safe...

Standard - Safe isolation

Electromagnetic compatibi...

Frequency range

Surge voltage load (surge...

Conducted interference

UNSPSC 21.0

Depth with alternative as...

Nominal input voltage ran...

Frequency range DC

Inrush current

Nominal output voltage

Derating

Control deviation

Maximum power dissipation...

Efficiency

Conductor cross section s...

Conductor cross section f...

Screw thread

Standard – Protection aga...

Rail applications

Discharge in air

Comments

I/O/S

UNSPSC 18.0

UNSPSC 19.0

Inflammability class in a...

Installation distance top...

Frequency range (fN)

Input fuse

Power factor (cos phi)

Voltage dips

Installation distance rig...

Foot latch material

Mains variation/undervolt...

Selected product

2316420
0 in stock
2316420
Phoenix Contact

Stainless steel field junction box with ten ports for use in hazardous locations. Includes six-spur ...

Depth127 mm

Colorgray

Max. output voltage UoUin (spur)

Additional textper spur

Max. output power Po1.792 W

UL, USA/CanadaClass I, Zone 2, AEx nA [ic]...

Height254 mm

Degree of protectionIP66

Housing materialStainless steel

Max. external inductivity Lo0.26 mH

Safety-related maximum voltage Um17.5 V (in acc. with EN 6007...

REACh SVHCLead 7439-92-1

ECLASS 4.127250203

ECLASS 5.127259205

Ambient temperature (operation)-40 °C ... 70 °C

Net weight4640 g

Max. current consumption4.8 mA (No-load)

Max. external capacitance Co80 nF

ECLASS 10.0.127180101

ECLASS 5.027250203

Utilization restrictionUse in potentially explosive...

Ambient temperature (storage/transport)-40 °C ... 70 °C

ConformanceCE-compliant, additionally E...

Mounting typeWall mounting

Inductance Li4 µH

ETIM 3.0EC001600

ETIM 6.0EC000261

UNSPSC 13.243201553

Width254 mm

ATEXDEMKO 16ATEX1704X II 3 G DEx...

ECLASS 6.027180100

ECLASS 7.027180101

UNSPSC 12.0139121008

Input voltage Ui32 V (IIB (C/D))

Max. output current Io56 mA (spur)

IECExIECEx UL 16.0079XEx nA [ic] ...

ECLASS 4.027250203

ECLASS 9.027180101

UNSPSC 6.0130211506

ECLASS 11.027180101

ETIM 7.0EC000261

UNSPSC 7.090139121008

GroupIIC/IIB

Standards/regulationsEN 61326-1

ETIM 4.0EC000261

UNSPSC 1139121008

Ambient temperature (start-up type tested)-

Degree of pollution-

Discharge current to PE-

Mains buffering time-

Protective circuit/component-

Connection in parallel-

Output power-

MTBF (IEC 61709, SN 29500)-

Insulation voltage output / PE-

Conductor cross section solid min.-

Conductor cross section AWG max.-

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations-

UL approvals-

Contact discharge-

Test field strength-

Input-

Criterion B-

Max. permissible relative humidity (operation)-

Input voltage range-

AC frequency range-

Recommended breaker for input protection-

POWER BOOST (IBoost)-

Connection in series-

Active current limitation-

Typical response time-

Assembly instructions-

Connection method-

Standard - Safety of transformers-

Standard – Limitation of mains harmonic currents-

Electromagnetic HF field-

Signal-

Criterion A-

Width with alternative assembly-

Installation height-

Nominal power consumption-

Nominal output current (IN)-

Selective Fuse Breaking (ISFB)-

Protection against overvoltage at the output (OVP)-

Insulation voltage input / PE-

Mounting position-

Conductor cross section flexible min.-

Stripping length-

EMC requirements for noise emission-

Standard – Safety extra-low voltage-

Standard - Approval for medical use-

CSA-

Electrostatic discharge-

Low Voltage Directive-

Fast transients (burst)-

Output-

Voltage-

China RoHS-

UNSPSC 20.0-

Height with alternative assembly-

Climatic class-

Current consumption-

Type of protection-

Setting range of the output voltage (USet)-

Feedback voltage resistance-

Residual ripple-

Power loss nominal load max.-

Insulation voltage input/output-

Protection class-

Conductor cross section AWG min.-

EMC requirements for noise immunity-

Standard - Electrical safety-

Standard - Equipment safety-

Standard - Safe isolation-

Electromagnetic compatibility-

Frequency range-

Surge voltage load (surge)-

Conducted interference-

UNSPSC 21.0-

Depth with alternative assembly-

Nominal input voltage range-

Frequency range DC-

Inrush current-

Nominal output voltage-

Derating-

Control deviation-

Maximum power dissipation in no-load condition-

Efficiency-

Conductor cross section solid max.-

Conductor cross section flexible max.-

Screw thread-

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-

Rail applications-

Discharge in air-

Comments-

I/O/S-

UNSPSC 18.0-

UNSPSC 19.0-

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Installation distance top/bottom-

Frequency range (fN)-

Input fuse-

Power factor (cos phi)-

Voltage dips-

Installation distance right/left-

Foot latch material-

Mains variation/undervoltage-

2320827
3 in stock
2320827
Phoenix Contact

Primary-switched power supply unit, QUINT POWER, Screw connection, DIN rail mounting, SFB Technology...

Depth179 mm

Color-

Max. output voltage Uo-

Additional text-

Max. output power Po-

UL, USA/Canada-

Height130 mm

Degree of protectionIP20

Housing materialSteel sheet, zinc-plated

Max. external inductivity Lo-

Safety-related maximum voltage Um-

REACh SVHCLead 7439-92-1

ECLASS 4.127040700

ECLASS 5.127242200

Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C De...

Net weight2.5 kg

Max. current consumption-

Max. external capacitance Co-

ECLASS 10.0.127040701

ECLASS 5.027242200

Utilization restriction-

Ambient temperature (storage/transport)-40 °C ... 85 °C

Conformance-

Mounting type-

Inductance Li-

ETIM 3.0EC001039

ETIM 6.0EC002540

UNSPSC 13.239121004

Width96 mm

ATEX-

ECLASS 6.027049000

ECLASS 7.027049002

UNSPSC 12.0139121004

Input voltage Ui-

Max. output current Io-

IECEx-

ECLASS 4.027040700

ECLASS 9.027040701

UNSPSC 6.0130211502

ECLASS 11.027040701

ETIM 7.0EC002540

UNSPSC 7.090139121004

Group-

Standards/regulations-

ETIM 4.0EC002540

UNSPSC 1139121004

Ambient temperature (start-up type tested)-40 °C

Degree of pollution2

Discharge current to PE< 3.5 mA

Mains buffering timetyp. 25 ms (400 V AC)

Protective circuit/componentVaristor

Connection in parallelYes, for redundancy and incr...

Output power960 W

MTBF (IEC 61709, SN 29500)> 890000 h (25 °C)

Insulation voltage output / PE500 V DC (routine test)

Conductor cross section solid min.0.2 mm²

Conductor cross section AWG max.10

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

UL approvalsUL Listed UL 508

Contact discharge8 kV (Test Level 4)

Test field strength10 V/m (Test Level 3)

Input2 kV (Test Level 3 - symmetr...

Criterion BTemporary impairment to oper...

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-conden...

Input voltage range3x 320 V AC ... 575 V AC

AC frequency range45 Hz ... 65 Hz

Recommended breaker for input protection6 A ... 16 A (AC: Characteri...

POWER BOOST (IBoost)22.5 A (-25 °C ... 40 °C per...

Connection in seriesyes

Active current limitationApprox. IBOOST = 22.5 A (for...

Typical response time< 1 s

Assembly instructionsalignable: PN ≥50%, 5 mm hor...

Connection methodScrew connection

Standard - Safety of transformersIEC 61558-2-17

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Electromagnetic HF fieldEN 61000-4-3

Signal1 kV (Test Level 2 - asymmet...

Criterion ANormal operating behavior wi...

Width with alternative assembly176 mm

Installation height4000 m

Nominal power consumption1386 VA

Nominal output current (IN)20 A (-25 °C ... 60 °C, UOUT...

Selective Fuse Breaking (ISFB)100 A (12 ms)

Protection against overvoltage at the output (OVP)< 60 V DC

Insulation voltage input / PE3.5 kV AC (type test)

Mounting positionhorizontal DIN rail NS 35, E...

Conductor cross section flexible min.0.2 mm²

Stripping length10 mm

EMC requirements for noise emissionEN 61000-6-3

Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60...

Standard - Approval for medical useIEC 60601-1, 2 x MOOP

CSACAN/CSA-C22.2 No. 60950-1-07

Electrostatic dischargeEN 61000-4-2

Low Voltage DirectiveConformance with Low Voltage...

Fast transients (burst)EN 61000-4-4

Output1 kV (Test Level 2 - symmetr...

Voltage10 V (Test Level 3)

China RoHSEnvironmentally Friendly Use...

UNSPSC 20.039121004

Height with alternative assembly130 mm

Climatic class3K3 (in acc. with EN 60721)

Current consumption3x 2.1 A (400 V AC)

Type of protectionTransient surge protection

Setting range of the output voltage (USet)30 V DC ... 56 V DC (> 48 V ...

Feedback voltage resistancemax. 60 V DC

Residual ripple< 50 mVPP (with nominal valu...

Power loss nominal load max.70 W

Insulation voltage input/output4 kV AC (type test)

Protection classI

Conductor cross section AWG min.18

EMC requirements for noise immunityEN 61000-6-1

Standard - Electrical safetyIEC 60950-1/VDE 0805 (SELV)

Standard - Equipment safetyBG (design tested)

Standard - Safe isolationDIN VDE 0100-410

Electromagnetic compatibilityConformance with EMC Directi...

Frequency range0.15 MHz ... 80 MHz

Surge voltage load (surge)EN 61000-4-5

Conducted interferenceEN 61000-4-6

UNSPSC 21.039121004

Depth with alternative assembly99 mm

Nominal input voltage range3x 400 V AC ... 500 V AC

Frequency range DC0 Hz

Inrush current< 20 A (typical)

Nominal output voltage48 V DC ±1 %

Derating60 °C ... 70 °C (2.5%/K)

Control deviation< 1 % (change in load, stati...

Maximum power dissipation in no-load condition24 W

Efficiency> 93 % (at 400 V AC and nomi...

Conductor cross section solid max.6 mm²

Conductor cross section flexible max.4 mm²

Screw threadM3

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178

Rail applicationsEN 50121-4

Discharge in air15 kV (Test Level 4)

CommentsCriterion A

I/O/Sasymmetrical

UNSPSC 18.039121004

UNSPSC 19.039121004

Inflammability class in acc. with UL 94 (housing / terminal blocks)-

Installation distance top/bottom-

Frequency range (fN)-

Input fuse-

Power factor (cos phi)-

Voltage dips-

Installation distance right/left-

Foot latch material-

Mains variation/undervoltage-

2903002
56 in stock
2903002
Phoenix Contact

Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 15 V DC/100 W

Depth84 mm

Color-

Max. output voltage Uo-

Additional text-

Max. output power Po-

UL, USA/Canada-

Height90 mm

Degree of protectionIP20

Housing materialPolycarbonate

Max. external inductivity Lo-

Safety-related maximum voltage Um-

REACh SVHC-

ECLASS 4.127040700

ECLASS 5.127049000

Ambient temperature (operation)-25 °C ... 70 °C (> 55 °C De...

Net weight0.34 kg

Max. current consumption-

Max. external capacitance Co-

ECLASS 10.0.127040701

ECLASS 5.027049000

Utilization restriction-

Ambient temperature (storage/transport)-40 °C ... 85 °C

Conformance-

Mounting type-

Inductance Li-

ETIM 3.0EC001039

ETIM 6.0EC002540

UNSPSC 13.239121004

Width55 mm

ATEX-

ECLASS 6.027049000

ECLASS 7.027049002

UNSPSC 12.0139121004

Input voltage Ui-

Max. output current Io-

IECEx-

ECLASS 4.027040700

ECLASS 9.027040701

UNSPSC 6.0130211502

ECLASS 11.027040701

ETIM 7.0EC002540

UNSPSC 7.090139121004

Group-

Standards/regulations-

ETIM 4.0EC000599

UNSPSC 1139121004

Ambient temperature (start-up type tested)-

Degree of pollution2

Discharge current to PE-

Mains buffering time> 20 ms (120 V AC)

Protective circuit/componentVaristor

Connection in parallelYes, for redundancy and incr...

Output power100 W

MTBF (IEC 61709, SN 29500)> 727000 h (40 °C)

Insulation voltage output / PE-

Conductor cross section solid min.0.2 mm²

Conductor cross section AWG max.14

Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)

UL approvalsUL/C-UL listed UL 508

Contact discharge6 kV (Test Level 3)

Test field strength10 V/m

Input2 kV (Test Level 3 - symmetr...

Criterion BTemporary impairment to oper...

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-conden...

Input voltage range85 V AC ... 264 V AC

AC frequency range-

Recommended breaker for input protection6 A ... 16 A (Characteristic...

POWER BOOST (IBoost)-

Connection in seriesyes

Active current limitation-

Typical response time< 1 s

Assembly instructionsalignable: 0 mm horizontally...

Connection methodScrew connection

Standard - Safety of transformersEN 61558-2-16

Standard – Limitation of mains harmonic currentsEN 61000-3-2

Electromagnetic HF fieldEN 61000-4-3

Signal-

Criterion ANormal operating behavior wi...

Width with alternative assembly-

Installation height-

Nominal power consumption206.3 VA

Nominal output current (IN)6.67 A (-25 °C ... 55 °C)

Selective Fuse Breaking (ISFB)-

Protection against overvoltage at the output (OVP)≤ 25 V DC

Insulation voltage input / PE-

Mounting positionhorizontal DIN rail NS 35, E...

Conductor cross section flexible min.0.2 mm²

Stripping length8 mm

EMC requirements for noise emissionEN 61000-6-3

Standard – Safety extra-low voltageIEC 62368-1 (SELV) und EN 60...

Standard - Approval for medical use-

CSACAN/CSA-C22.2 No. 60950-1-07

Electrostatic dischargeEN 61000-4-2

Low Voltage DirectiveConformance with Low Voltage...

Fast transients (burst)EN 61000-4-4

Output1 kV (Test Level 2 - symmetr...

Voltage10 V (Test Level 3)

China RoHSEnvironmentally Friendly Use...

UNSPSC 20.039121004

Height with alternative assembly-

Climatic class3K3 (in acc. with EN 60721)

Current consumption2.19 A (100 V AC)

Type of protectionTransient surge protection

Setting range of the output voltage (USet)-

Feedback voltage resistance< 25 V DC

Residual ripple< 75 mVPP (with nominal valu...

Power loss nominal load max.< 12 W

Insulation voltage input/output4 kV AC (type test)

Protection classII (in closed control cabine...

Conductor cross section AWG min.24

EMC requirements for noise immunityEN 61000-6-1

Standard - Electrical safetyIEC 62368-1/VDE 0805 (SELV)

Standard - Equipment safety-

Standard - Safe isolationDIN VDE 0100-410

Electromagnetic compatibilityConformance with EMC Directi...

Frequency range10 kHz ... 80 MHz

Surge voltage load (surge)EN 61000-4-5

Conducted interferenceEN 61000-4-6

UNSPSC 21.039121004

Depth with alternative assembly-

Nominal input voltage range100 V AC ... 240 V AC

Frequency range DC-

Inrush current< 30 A (typical)

Nominal output voltage15 V DC ±1 %

Derating55 °C ... 70 °C (2.5%/K)

Control deviation< 1 % (change in load, stati...

Maximum power dissipation in no-load condition< 0.4 W

Efficiencytyp. 89 % (120 V AC)

Conductor cross section solid max.2.5 mm²

Conductor cross section flexible max.2.5 mm²

Screw threadM3

Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment-

Rail applications-

Discharge in air8 kV (Test Level 3)

CommentsCriterion A

I/O/S-

UNSPSC 18.039121004

UNSPSC 19.039121004

Inflammability class in acc. with UL 94 (housing / terminal blocks)V0

Installation distance top/bottom30 mm / 30 mm

Frequency range (fN)50 Hz ... 60 Hz 10 %

Input fuse4 A (slow-blow, internal)

Power factor (cos phi)0.54

Voltage dipsEN 61000-4-11

Installation distance right/left0 mm / 0 mm

Foot latch materialPOM (Polyoxymethylen)

Mains variation/undervoltageEN 61000-4-11

About the manufacturer

Phoenix Contact

Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

About the Product Category

Devices for networking, which can be either hardware or software components, enable communication and data sharing among devices within a computer network. Their role is to create and sustain connectivity, improve the performance of the network, and safeguard data.

Data & Networking Devices

Relevant products

FAQ

Out if stock but available for backorder.

Stainless steel field junction box with ten ports for use in hazardous locations. Includes six-spur block device coupler (FB-6SP) for Foundation Fieldbus or PROFIBUS PA, three terminal blocks for trunk cable connection (+, –, S).

What can I help you find today?

Recommended parts