Axioline Smart Elements, Digital input module, SafetyBridge technology, Safe digital inputs: 8 (1-channel assignment), 4 (2-channel assignment), 24 V DC, connection method: 3-conductor, degree of protection: IP20

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 1190012 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Height
    62.2 mm
  • Permissible humidity (storage/transport)
    5 % ... 95 % (non-condensing)
  • Degree of protection
    IP20
  • Conductor cross section solid max.
    1.5 mm²
  • Conductor cross section AWG min.
    24
  • Cable length
    max. 200 m (200 m from the clock output to the safe input (total based on forward and return path))
  • Nominal voltage UN
    24 V DC (from UP)
  • Short-circuit protection
    Yes
  • Mounting position
    any
  • Supply voltage range
    19.2 V DC ... 30 V DC (including all tolerances, including ripple)
  • Category
    3 (1-channel assignment)
  • Immunity to burst
    Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, 2 kV
  • Protection class
    III (IEC 61140, EN 61140, VDE 0140-1)
  • ECLASS 9.0
    27242604
  • Caption
    Dimensions
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Air pressure (storage/transport)
    66 kPa ... 108 kPa
  • Designation
    EN 62061
  • Number
    1
  • Connection technology
    3-conductor
  • Number of inputs
    8 (1-channel assignment)
  • Input current range "0" signal
    max. 1.5 mA
  • Limiting continuous current
    max. 0.5 A DC (per clock output)
  • Operating mode
    SafetyBridge
  • Maximum altitude
    ≤ 3000 m (Above sea level)
  • Protection
    external fusing via the system in which the Smart Element is used
  • Immunity to surge
    Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Test intensity 2, Criterion APower supply: 0.5 kV/0.5 kV (symmetrical/unsymmetrical)Signal lines: 1.0 kV/2.0 kV (symmetrical/unsymmetrical)
  • Overvoltage category
    II (IEC 60664-1)
  • Depth
    62 mm
  • Air pressure (operation)
    70 kPa ... 108 kPa
  • Note on the connection method
    Note the specification in the section Conductor cross sections, and stripping and insertion lengths.
  • Conductor cross section AWG max.
    16
  • Transmission speed
    See system in which you use the Smart Element.
  • Protective circuit
    Surge protection of the supply voltage electronic (35 V, 0.5 s)
  • Nominal input current at UIN
    typ. 2.7 mA
  • Input current range “1“ signal
    min. 2 mA
  • Mounting type
    Smart Element slot
  • Net weight
    36 g
  • Power consumption
    min. 154 mW
  • Performance level (PL)
    d (1-channel assignment)
  • Immunity to EF
    Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
  • Air clearances and creepage distances
    IEC 60664-1
  • ECLASS 10.0.1
    27242604
  • Width
    14.9 mm
  • Permissible humidity (operation)
    5 % ... 95 % (non-condensing)
  • Connection method
    Push-in connection
  • Conductor cross section solid min.
    0.25 mm²
  • Conductor cross section flexible min.
    0.25 mm²
  • Description of the input
    EN 61131-2, type 3
  • Nominal input voltage UIN
    24 V DC
  • Input filter time
    1.5 ms
  • Input voltage range "1" signal
    11 V DC ... 30 V DC
  • Switching frequency
    max. 10 Hz
  • Degree of pollution
    2 (EN 60664-1)
  • Current consumption
    min. 8 mA (Power supply from Up with 19.2 V DC, all inputs set, without power supply to the sensors via clock supplies OUT_T1 and OUT_T2)
  • Safety Integrity Level Claim Limit (SIL CL)
    2 (1-channel assignment)
  • Immunity to ESD
    Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion A, 6 kV contact discharge, 8 kV air discharge
  • Immunity to conducted interference
    Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
  • ECLASS 11.0
    27242604
  • Conductor cross section flexible max.
    1.5 mm²
  • Stripping length
    8 mm
  • Input voltage range "0" signal
    -3 V DC ... 5 V DC
  • Ambient temperature (operation)
    -25 °C ... 60 °C
  • Degree of protection at installation location
    min. IP54
  • Input name
    Safe digital inputs
  • Number of outputs
    2
  • Color
    zinc yellow RAL 1018
  • Supply voltage
    24 V DC (using card edge connectors)
  • Additional text
    using card edge connectors
  • Safety Integrity Level (SIL)
    2 (1-channel assignment)
  • Interference emission
    Noise emission test as per EN 61000-6-4 Class A (industrial applications)
  • Mechanical tests
    Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

Relevant products

What can I help you find today?

Recommended parts