1190012 Phoenix Contact Programmable Logic Controllers
Part#:1190012
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline Smart Elements, Digital input module, SafetyBridge technology, Safe digital inputs: 8 (1-channel assignment), 4 (2-channel assignment), 24 V DC, connection method: 3-conductor, degree of protection: IP20
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1190012 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 62.2 mm
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Degree of protection IP20
- Conductor cross section solid max. 1.5 mm²
- Conductor cross section AWG min. 24
- Cable length max. 200 m (200 m from the clock output to the safe input (total based on forward and return path))
- Nominal voltage UN 24 V DC (from UP)
- Short-circuit protection Yes
- Mounting position any
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Category 3 (1-channel assignment)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, 2 kV
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 9.0 27242604
- Caption Dimensions
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Air pressure (storage/transport) 66 kPa ... 108 kPa
- Designation EN 62061
- Number 1
- Connection technology 3-conductor
- Number of inputs 8 (1-channel assignment)
- Input current range "0" signal max. 1.5 mA
- Limiting continuous current max. 0.5 A DC (per clock output)
- Operating mode SafetyBridge
- Maximum altitude ≤ 3000 m (Above sea level)
- Protection external fusing via the system in which the Smart Element is used
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Test intensity 2, Criterion APower supply: 0.5 kV/0.5 kV (symmetrical/unsymmetrical)Signal lines: 1.0 kV/2.0 kV (symmetrical/unsymmetrical)
- Overvoltage category II (IEC 60664-1)
- Depth 62 mm
- Air pressure (operation) 70 kPa ... 108 kPa
- Note on the connection method Note the specification in the section Conductor cross sections, and stripping and insertion lengths.
- Conductor cross section AWG max. 16
- Transmission speed See system in which you use the Smart Element.
- Protective circuit Surge protection of the supply voltage electronic (35 V, 0.5 s)
- Nominal input current at UIN typ. 2.7 mA
- Input current range “1“ signal min. 2 mA
- Mounting type Smart Element slot
- Net weight 36 g
- Power consumption min. 154 mW
- Performance level (PL) d (1-channel assignment)
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Air clearances and creepage distances IEC 60664-1
- ECLASS 10.0.1 27242604
- Width 14.9 mm
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Connection method Push-in connection
- Conductor cross section solid min. 0.25 mm²
- Conductor cross section flexible min. 0.25 mm²
- Description of the input EN 61131-2, type 3
- Nominal input voltage UIN 24 V DC
- Input filter time 1.5 ms
- Input voltage range "1" signal 11 V DC ... 30 V DC
- Switching frequency max. 10 Hz
- Degree of pollution 2 (EN 60664-1)
- Current consumption min. 8 mA (Power supply from Up with 19.2 V DC, all inputs set, without power supply to the sensors via clock supplies OUT_T1 and OUT_T2)
- Safety Integrity Level Claim Limit (SIL CL) 2 (1-channel assignment)
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion A, 6 kV contact discharge, 8 kV air discharge
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- ECLASS 11.0 27242604
- Conductor cross section flexible max. 1.5 mm²
- Stripping length 8 mm
- Input voltage range "0" signal -3 V DC ... 5 V DC
- Ambient temperature (operation) -25 °C ... 60 °C
- Degree of protection at installation location min. IP54
- Input name Safe digital inputs
- Number of outputs 2
- Color zinc yellow RAL 1018
- Supply voltage 24 V DC (using card edge connectors)
- Additional text using card edge connectors
- Safety Integrity Level (SIL) 2 (1-channel assignment)
- Interference emission Noise emission test as per EN 61000-6-4 Class A (industrial applications)
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
Relevant products
What can I help you find today?