1190017 Phoenix Contact Programmable Logic Controllers
Part#:1190017
Manufacturer:Phoenix Contact
Category:Programmable Logic Controllers
Product Lifecycle:Active
Get a quick Quote!
Axioline Smart Elements, Digital output module, SafetyBridge technology, Safe digital outputs: 4 (1-channel assignment), 2 (2-channel assignment), 24 V DC, 2 A, connection method: 2-conductor, degree of protection: IP20
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Programmable Logic Controllers that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 1190017 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Permissible humidity (operation) 5 % ... 95 % (non-condensing)
- Connection method Push-in connection
- Conductor cross section flexible max. 1.5 mm²
- Output name Safe digital outputs
- Transmission speed See system in which you use the Smart Element.
- Number of outputs 4 (1-channel assignment)
- Switching frequency 1 Hz (0.2 Hz at > 1 A)
- Derating up to 40°C: 4 A total currentfrom 40°C: 100 mA/°C derating
- Behavior with inductive overload Output can be destroyed
- Test pulses Configurable switch-on impulses, fixed shut-off impulses
- Maximum altitude ≤ 3000 m (Above sea level)
- Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
- Degree of protection at installation location min. IP54
- Conductor cross section AWG max. 16
- Output voltage 24 V DC
- Output current max. 2 A (per output)
- Category 3 (1-channel assignment)
- Immunity to burst Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, 2 kV
- Protection class III (IEC 61140, EN 61140, VDE 0140-1)
- ECLASS 10.0.1 27242604
- Width 14.9 mm
- Air pressure (operation) 70 kPa ... 108 kPa
- Holding voltage > 5 V (min. holding voltage of the connected load)
- Reverse voltage resistance to short pulses no
- Operating mode SafetyBridge
- Supply voltage 24 V DC (using card edge connectors)
- Safety Integrity Level (SIL) 2 (1-channel assignment)
- Depth 62 mm
- Load min. 1.5 kΩ (at nominal voltage)
- Holding current > 2 mA (min. holding current of the connected load)
- Mounting type Smart Element slot
- Mounting position any
- Stop category in accordance with IEC 60204 0
- Safety Integrity Level Claim Limit (SIL CL) 2 (1-channel assignment)
- Mechanical tests Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
- Interference emission Noise emission test as per EN 61000-6-4 Class A (industrial applications)
- ECLASS 11.0 27242604
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Conductor cross section flexible min. 0.25 mm²
- Number 1
- Nominal load, inductive 48 VA (1 H; 12 Ω; at nominal voltage)
- Stripping length 8 mm
- Connection technology 2-conductor
- Nominal output voltage 24 V DC
- Nominal load, ohmic 48 W (12 Ω, at nominal voltage)
- Output voltage when switched off < 5 V
- Output current when switched off < 2 mA
- Color zinc yellow RAL 1018
- Current consumption min. 21 mA ((Supply from UP with 19.2 V DC, all outputs set, without supply to the actuators))
- Performance level (PL) d (1-channel assignment)
- Immunity to ESD Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion A, 6 kV contact discharge, 8 kV air discharge
- Immunity to conducted interference Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
- Air clearances and creepage distances IEC 60664-1
- Height 62.2 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Air pressure (storage/transport) 66 kPa ... 108 kPa
- Designation EN 62061
- Note on the connection method Note the specification in the section Conductor cross sections, and stripping and insertion lengths.
- Conductor cross section AWG min. 24
- Output description EN 61131-2
- Protective circuit Short-circuit protection, overload protection of the outputs electronic
- Max. capacitive load 10 µF (for ZVEI class 0)
- Limitation of the voltage induced on circuit interruption -15 V
- Behavior with overload Switch-off of the relevant output, restart upon acknowledgment
- Net weight 36 g
- Degree of pollution 2 (EN 60664-1)
- Additional text using card edge connectors
- Power consumption min. 403 mW
- Immunity to EF Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
- Immunity to surge Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Test intensity 2, Criterion APower supply: 0.5 kV/0.5 kV (symmetrical/unsymmetrical)Signal lines: 1.0 kV/2.0 kV (symmetrical/unsymmetrical)
- Overvoltage category II (IEC 60664-1)
- ECLASS 9.0 27242604
- Caption Dimensions
- Ambient temperature (operation) -25 °C ... 60 °C
- Degree of protection IP20
- Conductor cross section solid min. 0.25 mm²
- Conductor cross section solid max. 1.5 mm²
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?