3969927 Phoenix Contact Terminal Blocks

3969927 on Power Resource International
Phoenix Contact

Part#:3969927

Manufacturer:Phoenix Contact

Category:Terminal Blocks

Product Lifecycle:Active

Get a quick Quote!

Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Ring cable lug, number of connections: 24, number of positions: 12, width: 130.4 mm, height: 70.1 mm, color: gray, mounting type: Wall mounting

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3969927 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Result of temperature-rise test
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • ECLASS 5.1
    27141100
  • Conductor cross section short circuit testing
    4 mm²
  • Oscillation, broadband noise test result
    Test passed
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • ECLASS 4.1
    27141100
  • ECLASS 5.0
    27141100
  • Setpoint
    5 N
  • Result of thermal test
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Shock form
    Half-sine
  • Static insulating material application in cold
    -60 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Width
    130.4 mm
  • Screw thread
    No 8 UNC
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • ECLASS 9.0
    27141126
  • UNSPSC 6.01
    30211811
  • UNSPSC 21.0
    39121410
  • Number of connections
    24
  • Insulating material
    PA
  • Maximum load current
    30 A (with 10 mm² conductor cross section)
  • Terminal block mounting
    0.8 Nm ... 1 Nm
  • Result of surge voltage test
    Test passed
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Tightening torque, min
    1.5 Nm
  • 2 conductors with same cross section, solid max.
    6 mm²
  • Min. tightening torque of the mounting screw:
    0.8 Nm
  • Number of levels
    1
  • Color
    gray
  • Potentials
    12
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Number of positions
    12
  • Test surge voltage
    5 kV
  • Nominal cross section
    6 mm²
  • Note regarding shock protection
    Back of hand protection without cable lug, as well as with insulated and uninsulated cable lugs with shrink sleeve with tightened clamping screw.
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Shock test result
    Test passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Nominal voltage UN
    400 V AC/DC
  • Back of the hand protection
    guaranteed
  • Rated surge voltage
    4 kV
  • Insulating material group
    I
  • Acceleration
    30g
  • Number of shocks per direction
    3
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Flammability rating according to UL 94
    V0
  • Maximum power dissipation for nominal condition
    1.31 W
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Short-time current
    1250 A
  • Overvoltage category
    III
  • Open side panel
    No
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of tight fit on support
    Test passed
  • Note
    Test with 4 mm² / 500 A / 1 s includes test with 4 mm² / 480 A / 1 s in accordance with IEC 60947-7-1:2009-04.
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Pitch
    8.2 mm
  • Stripping length
    12 mm
  • Conductor cross section flexible max.
    10 mm²
  • 2 conductors with same cross section, stranded min.
    0.5 mm²
  • Max. cross section for cable lug connection
    10 mm²
  • Max. tightening torque of the mounting screw:
    1 Nm
  • Internal cylindrical gage
    A5
  • Height
    70.1 mm
  • Connection
    1 level
  • Min. AWG conductor cross section, flexible
    24
  • Cable lug connection according to standard
    DIN 46237:1970-07
  • Min. cross section for cable lug connection
    0.5 mm²
  • Bolt diameter
    4.1 mm
  • Result of voltage-drop test
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Connection method
    Ring cable lug
  • Tightening torque max
    1.8 Nm
  • 2 conductors with same cross section, stranded max.
    6 mm²
  • Hole diameter, min.
    4.3 mm
  • 2 conductors with same cross section, solid min.
    0.5 mm²
  • REACh SVHC
    Lead 7439-92-1
  • UNSPSC 7.0901
    39121410
  • UNSPSC 13.2
    39121410
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Plate thickness
    1 mm ... 4 mm
  • Connection in acc. with standard
    IEC 60947-7-1
  • Max. AWG conductor cross section, flexible
    8
  • ECLASS 10.0.1
    27141126
  • ECLASS 7.0
    27141126
  • ETIM 7.0
    EC000902
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Length
    81 mm
  • Cable lug width, max.
    8 mm
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 4.0
    27141100
  • ECLASS 6.0
    27141100
  • ETIM 4.0
    EC000897
  • Test duration per axis
    5 h
  • Mounting type
    Wall mounting
  • ECLASS 11.0
    27141126
  • UNSPSC 18.0
    39121410
  • UNSPSC 20.0
    39121410
  • Short circuit stability result
    Test passed
  • Shock duration
    18 ms
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Conductor cross section flexible min.
    0.5 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ETIM 6.0
    EC000902
  • UNSPSC 11
    39121410
  • UNSPSC 19.0
    39121410
  • UNSPSC 12.01
    39121410

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us