3273208 Phoenix Contact Terminal Blocks

3273208 on Power Resource International
Phoenix Contact

Part#:3273208

Manufacturer:Phoenix Contact

Category:Terminal Blocks

Product Lifecycle:Active

Get a quick Quote!

Distribution block, Block with horizontal alignment and integrated supply, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 690 V, nominal current: 24 A, connection metho

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3273208 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Potentials
    1
  • Note
    The max. load current must not be exceeded by the total current of all connected conductors.
  • Color
    brown
  • Overvoltage category
    III
  • Maximum total current
    57 A (with 10 mm² conductor cross section)
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Result of flexion and pull-out test
    Test passed
  • Bending test conductor cross section/weight
    0.5 mm² / 0.3 kg
  • Result of voltage-drop test
    Test passed
  • Result of thermal test
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Conductor cross section solid max.
    10 mm²
  • Conductor cross section flexible max.
    10 mm²
  • Internal cylindrical gage
    A3
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Value
    1 mm²
  • ECLASS 4.0
    27141121
  • ECLASS 4.1
    27141121
  • ETIM 3.0
    EC000897
  • UNSPSC 11
    39121410
  • UNSPSC 18.0
    39121410
  • Nominal cross section
    2.5 mm²
  • Degree of pollution
    3
  • Maximum load current
    57 A (with 10 mm² conductor cross section)
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of power-frequency withstand voltage test
    Test passed
  • Tensile test result
    Test passed
  • Short-time current
    1.2 kA
  • Conductor cross section short circuit testing
    10 mm²
  • Test duration per axis
    5 h
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Shock duration
    18 ms
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Height NS 35/7,5
    30.9 mm
  • Connection in acc. with standard
    IEC 60947-7-1
  • Min. AWG conductor cross section, flexible
    20
  • Connection cross sections directly pluggable
    1 mm² 10 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.0
    27141120
  • UNSPSC 6.01
    30211811
  • UNSPSC 19.0
    39121410
  • Number of connections
    7
  • Insulating material
    PA
  • Rated surge voltage
    8 kV
  • Maximum power dissipation for nominal condition
    1.31 W (the value is based on one connection block and is multiplied according to the pin assignment)
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Bending test rotation speed
    10 rpm
  • Tight fit on carrier
    NS 35
  • Short circuit stability result
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Shock form
    Half-sine
  • Number of shocks per direction
    3
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Width
    25.6 mm
  • Connection method
    Push-in connection
  • Conductor cross section AWG min.
    20
  • Conductor cross section AWG max.
    8
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1.5 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141120
  • ECLASS 6.0
    27141100
  • ECLASS 7.0
    27141120
  • ETIM 6.0
    EC000897
  • UNSPSC 12.01
    39121410
  • Number of levels
    1
  • Flammability rating according to UL 94
    V0
  • Nominal current IN
    41 A (with 6 mm² conductor cross section)
  • Open side panel
    No
  • Back of the hand protection
    guaranteed
  • Bending test turns
    135
  • Setpoint
    5 N
  • Result of temperature-rise test
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Shock test result
    Test passed
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Length
    45.7 mm
  • Conductor cross section solid min.
    1 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.5 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.5 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 5.1
    27141120
  • ETIM 4.0
    EC000897
  • UNSPSC 13.2
    39121410
  • UNSPSC 21.0
    39121410
  • Nominal cross section feed-in
    6 mm²
  • Insulating material group
    I
  • Nominal voltage UN
    690 V
  • Finger protection
    guaranteed
  • Result of surge voltage test
    Test passed
  • Result of tight fit on support
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Result of aging test
    Test passed
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Acceleration
    30g
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Stripping length
    10 mm ... 12 mm
  • Conductor cross section flexible min.
    0.5 mm²
  • Max. AWG conductor cross section, flexible
    10
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • Connection
    Feed-in stage
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 10.0.1
    27141120
  • ETIM 7.0
    EC000897
  • ECLASS 9.0
    27141120
  • UNSPSC 7.0901
    39121410
  • UNSPSC 20.0
    39121410
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?