3273192 Phoenix Contact Terminal Blocks

3273192 on Power Resource International
Phoenix Contact

Part#:3273192

Manufacturer:Phoenix Contact

Category:Terminal Blocks

Product Lifecycle:Active

Get a quick Quote!

Distribution block, Block with horizontal alignment, The blocks can be bridged with one another via the conductor shaft. For corresponding plug-in bridges, see accessories, nom. voltage: 690 V, nominal current: 24 A, connection method: Push-in connection,

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3273192 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Insulating material group
    I
  • Open side panel
    No
  • Note
    The max. load current must not be exceeded by the total current of all connected conductors.
  • Insulating material
    PA
  • Number of levels
    1
  • Rated surge voltage
    8 kV
  • Maximum power dissipation for nominal condition
    0.77 W (the value is based on one connection block and is multiplied according to the pin assignment)
  • Maximum total current
    48 A
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of power-frequency withstand voltage test
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Setpoint
    1 N
  • Short circuit stability result
    Test passed
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Acceleration
    30g
  • Shock test result
    Test passed
  • Static insulating material application in cold
    -60 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Potentials
    1
  • Flammability rating according to UL 94
    V0
  • Maximum load current
    32 A
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Bending test rotation speed
    10 rpm
  • Result of voltage-drop test
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Result of aging test
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Shock duration
    18 ms
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Width
    46.9 mm
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section AWG min.
    26
  • Nominal cross section
    2.5 mm²
  • Degree of pollution
    3
  • Nominal current IN
    24 A
  • Finger protection
    guaranteed
  • Bending test conductor cross section/weight
    0.14 mm² / 0.2 kg
  • Result of tight fit on support
    Test passed
  • Number of connections
    18
  • Color
    violet
  • Overvoltage category
    III
  • Nominal voltage UN
    690 V
  • Back of the hand protection
    guaranteed
  • Tensile test result
    Test passed
  • Bending test turns
    135
  • Result of temperature-rise test
    Test passed
  • Short-time current
    0.48 kA
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • ASD level
    6.12 (m/s2)2/Hz
  • Test duration per axis
    5 h
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Length
    45.7 mm
  • Conductor cross section solid min.
    0.34 mm²
  • Conductor cross section solid max.
    4 mm²
  • Max. AWG conductor cross section, flexible
    14
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.34 mm²
  • Connection cross sections directly pluggable
    0.34 mm² 4 mm² 24 12
  • ECLASS 10.0.1
    27141120
  • ECLASS 5.1
    27141120
  • ECLASS 6.0
    27141100
  • ETIM 4.0
    EC000897
  • UNSPSC 7.0901
    39121410
  • UNSPSC 21.0
    39121410
  • UNSPSC 18.0
    39121410
  • Tight fit on carrier
    NS 35
  • Conductor cross section short circuit testing
    4 mm²
  • Oscillation, broadband noise test result
    Test passed
  • Number of shocks per direction
    3
  • Shock form
    Half-sine
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Connection method
    Push-in connection
  • Height NS 35/7,5
    30.9 mm
  • Conductor cross section AWG max.
    12
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    2.5 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.34 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 4.0
    27141121
  • ECLASS 9.0
    27141120
  • ETIM 6.0
    EC000897
  • UNSPSC 11
    39121410
  • UNSPSC 20.0
    39121410
  • Stripping length
    8 mm ... 10 mm
  • Conductor cross section flexible min.
    0.14 mm²
  • Min. AWG conductor cross section, flexible
    26
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 11.0
    27141120
  • ECLASS 5.0
    27141120
  • UNSPSC 6.01
    30211811
  • ETIM 7.0
    EC000897
  • UNSPSC 19.0
    39121410
  • Internal cylindrical gage
    A3
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 7.0
    27141120
  • ETIM 3.0
    EC000897
  • UNSPSC 13.2
    39121410
  • UNSPSC 12.01
    39121410
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Result of surge voltage test
    Test passed
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • ECLASS 4.1
    27141121
  • Result of thermal test
    Test passed
  • Conductor cross section flexible max.
    2.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?