Get a quick Quote!
Component terminal block, with integrated 1N4007 diode, The max. current is determined by the diode. Installed: Diode 1N 4007, reverse voltage: 1300 V, maximum continuous current: 0.5 A., nom. voltage: 500 V, nominal current: 20 A, connection method: Push
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3213221 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Color gray
- Nominal current IN 20 A
- Back of the hand protection guaranteed
- Checking the mechanical stability of terminal points (5 x conductor connection) Test passed
- Result of tight fit on support Test passed
- Short circuit stability result Test passed
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test frequency f1 = 5 Hz to f2 = 250 Hz
- ASD level 6.12 (m/s2)2/Hz
- Shock duration 18 ms
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²
- ECLASS 10.0.1 27141127
- ECLASS 5.0 27141100
- ETIM 4.0 EC000897
- UNSPSC 13.2 39121410
- Number of levels 2
- Rated surge voltage 6 kV
- Maximum load current 26 A (with 4 mm² conductor cross section, rigid)
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Result of power-frequency withstand voltage test Test passed
- Bending test rotation speed 10 rpm
- Conductor cross section short circuit testing 4 mm²
- Result of thermal test Test passed
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Height NS 35/7,5 47.5 mm
- Connection method Push-in connection
- Conductor cross section flexible max. 4 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.14 mm²
- REACh SVHC Lead 7439-92-1
- ECLASS 7.0 27141127
- Nominal cross section 2.5 mm²
- Insulating material PA
- Insulating material group I
- Finger protection guaranteed
- Result of flexion and pull-out test Test passed
- Tight fit on carrier NS 35
- Result of aging test Test passed
- Oscillation, broadband noise test result Test passed
- Shock test result Test passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Length 68 mm
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm²
- ECLASS 4.1 27141100
- ECLASS 4.0 27141100
- ECLASS 6.0 27141100
- UNSPSC 11 39121410
- UNSPSC 18.0 39121410
- Note The max. current is determined by the diode. Installed: Diode 1N 4007, reverse voltage: 1300 V, maximum continuous current: 0.5 A.
- Overvoltage category III
- Maximum power dissipation for nominal condition 0.77 W (the value is multiplied when connecting multiple levels)
- Nominal voltage UN 500 V
- Surge voltage test setpoint 7.3 kV
- Bending test conductor cross section/weight 0.14 mm² / 0.2 kg
- Short-time current 0.48 kA
- Test spectrum Service life test category 2, bogie-mounted
- Test duration per axis 5 h
- Shock form Half-sine
- Static insulating material application in cold -60 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- End cover width 2.2 mm
- Conductor cross section solid max. 4 mm²
- Conductor cross section solid min. 0.14 mm²
- Conductor cross section AWG min. 26
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 0.5 mm²
- Stripping length 10 mm
- ECLASS 11.0 27141127
- ECLASS 9.0 27141127
- ETIM 7.0 EC000903
- UNSPSC 21.0 39121410
- Number of connections 4
- Flammability rating according to UL 94 V0
- Degree of pollution 3
- Open side panel Yes
- Result of surge voltage test Test passed
- Power frequency withstand voltage setpoint 1.89 kV
- Bending test turns 135
- Setpoint 1 N
- Ageing test for screwless modular terminal block temperature cycles 192
- Acceleration 30g
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2018-05
- Relative insulation material temperature index (Elec.; UL 746 B) 130 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Width 5.2 mm
- Height NS 35/15 55 mm
- Conductor cross section flexible min. 0.14 mm²
- Conductor cross section AWG max. 12
- Internal cylindrical gage A3
- ECLASS 5.1 27141100
- UNSPSC 6.01 30211811
- UNSPSC 12.01 39121410
- UNSPSC 20.0 39121410
- ETIM 3.0 EC000897
- ETIM 6.0 EC000903
- UNSPSC 7.0901 39121410
- UNSPSC 19.0 39121410
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2018-05
- Number of shocks per direction 3
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.