3070325 Phoenix Contact Terminal Blocks
Part#:3070325
Manufacturer:Phoenix Contact
Category:Terminal Blocks
Product Lifecycle:Active
Get a quick Quote!
Feed-through terminal block, nom. voltage: 500 V, nominal current: 41 A, connection method: Screw connection with spring support, number of connections: 2, cross section: 0.2 mm² - 10 mm², AWG: 24 - 8, width: 8.2 mm, color: gray, mounting type: NS 35/7,5,
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3070325 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Test specification, oscillation, broadband noise DIN EN 50155 (VDE 0115-200):2008-03
- ASD level 1.857 (m/s2)2/Hz
- Test specification, shock test DIN EN 50155 (VDE 0115-200):2008-03
- Number of shocks per direction 3
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- End cover width 2.2 mm
- Tightening torque max 1.8 Nm
- Conductor cross section AWG min. 24
- Conductor cross section flexible max. 6 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm²
- 2 conductors with same cross section, stranded min. 0.2 mm²
- Ambient temperature (actuation) -5 °C ... 70 °C
- China RoHS Environmentally Friendly Use Period = 50 years
- Permissible humidity (storage/transport) 30 % ... 70 %
- ETIM 6.0 EC000897
- Test spectrum Service life test category 1, class B, body mounted
- Acceleration 5g
- Test directions X-, Y- and Z-axis (pos. and neg.)
- Shock duration 30 ms
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Length 82 mm
- Connection method Screw connection with spring support
- Stripping length 12 mm
- Connection in acc. with standard CUL
- Conductor cross section AWG max. 8
- Conductor cross section flexible, with ferrule with plastic sleeve max. 6 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 4 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 4.1 27141100
- ECLASS 10.0.1 27141120
- ECLASS 5.0 27141100
- UNSPSC 12.01 39121410
- UNSPSC 18.0 39121410
- Color gray
- Test duration per axis 5 h
- Shock form Half-sine
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Height NS 35/15 59.5 mm
- Tightening torque, min 1.5 Nm
- Conductor cross section solid min. 0.2 mm²
- Max. AWG conductor cross section, flexible 10
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.25 mm²
- 2 conductors with same cross section, stranded max. 2.5 mm²
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 11.0 27141120
- ECLASS 5.1 27141100
- ECLASS 9.0 27141120
- ETIM 7.0 EC000897
- UNSPSC 19.0 39121410
- Short-time current 1.2 kA
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Test frequency f1 = 5 Hz to f2 = 150 Hz
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Width 8.2 mm
- Height NS 35/7,5 52 mm
- Height NS 32 57 mm
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 6 mm²
- 2 conductors with same cross section, solid max. 2.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- ECLASS 6.0 27141100
- ETIM 4.0 EC000897
- UNSPSC 11 39121410
- UNSPSC 20.0 39121410
- Result of thermal test Test passed
- Shock test result Test passed
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Connection 1 level
- Screw thread M4
- Conductor cross section solid max. 10 mm²
- Min. AWG conductor cross section, flexible 24
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.25 mm²
- 2 conductors with same cross section, solid min. 0.2 mm²
- Internal cylindrical gage A5
- ECLASS 4.0 27141100
- ECLASS 7.0 27141120
- ETIM 3.0 EC000897
- UNSPSC 6.01 30211811
- UNSPSC 21.0 39121410
- UNSPSC 7.0901 39121410
- UNSPSC 13.2 39121410
- Number of connections 2
- Rated surge voltage 6 kV
- Degree of pollution 3
- Result of power-frequency withstand voltage test Test passed
- Bending test turns 135
- Flammability rating according to UL 94 V0
- Maximum load current 57 A (with 10 mm² conductor cross section)
- Setpoint 5 N
- Back of the hand protection guaranteed
- Nominal current IN 41 A
- Open side panel Yes
- Finger protection guaranteed
- Bending test rotation speed 10 rpm
- Result of tight fit on support Test passed
- Short circuit stability result Test passed
- Nominal voltage UN 500 V (up to 690 V for pollution degree II)
- Result of surge voltage test Test passed
- Number of levels 1
- Nominal cross section 6 mm²
- Overvoltage category III
- Power frequency withstand voltage setpoint 1.89 kV
- Tensile test result Test passed
- Result of flexion and pull-out test Test passed
- Result of voltage-drop test Test passed
- Maximum power dissipation for nominal condition 1.31 W
- Bending test conductor cross section/weight 0.2 mm² / 0.2 kg
- Result of temperature-rise test Test passed
- Conductor cross section short circuit testing 10 mm²
- Tight fit on carrier NS 35/NS 32
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Oscillation, broadband noise test result Test passed
- Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11
- Potentials 1
- Insulating material group I
- Insulating material PA
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?