3070008 Phoenix Contact Terminal Blocks

3070008 on Power Resource International
Phoenix Contact

Part#:3070008

Manufacturer:Phoenix Contact

Category:Terminal Blocks

Product Lifecycle:Active

Get a quick Quote!

Test terminal strip, nom. voltage: 400 V AC/DC, nominal current: 24 A, connection method: Screw connection, number of connections: 10, number of positions: 5, cross section: 0.2 mm² - 10 mm², AWG: 24 - 8, width: 107 mm, height: 81 mm, color: gray, mountin

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3070008 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Plate thickness
    1 mm ... 4 mm
  • Overvoltage category
    III
  • Flammability rating according to UL 94
    V0
  • Open side panel
    No
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Width
    107 mm
  • Height
    81 mm
  • Stripping length
    10 mm
  • UNSPSC 18.0
    39121410
  • ECLASS 11.0
    27141126
  • ECLASS 7.0
    27141126
  • ETIM 4.0
    EC000901
  • Color
    gray
  • Number of levels
    1
  • Nominal voltage UN
    400 V AC/DC
  • Potentials
    5
  • Insulating material group
    I
  • Connection
    1 level
  • Max. tightening torque of the mounting screw:
    1 Nm
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Conductor cross section AWG min.
    24
  • Min. AWG conductor cross section, flexible
    24
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • Screw thread
    M4
  • Tightening torque, min
    1.5 Nm
  • Number of connections
    10
  • Test surge voltage
    5 kV
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.25 mm²
  • 2 conductors with same cross section, stranded max.
    2.5 mm²
  • Tightening torque max
    1.8 Nm
  • Conductor cross section solid min.
    0.2 mm²
  • Conductor cross section solid max.
    10 mm²
  • Conductor cross section flexible max.
    10 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • UNSPSC 12.01
    39121410
  • UNSPSC 21.0
    39121410
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • Max. AWG conductor cross section, flexible
    8
  • UNSPSC 11
    39121410
  • Nominal cross section
    6 mm²
  • Nominal current IN
    24 A
  • Connection method
    Screw connection
  • Connection in acc. with standard
    IEC 60947-7-1
  • 2 conductors with same cross section, stranded min.
    0.2 mm²
  • UNSPSC 7.0901
    39121410
  • UNSPSC 20.0
    39121410
  • Pitch
    8.2 mm
  • Conductor cross section AWG max.
    8
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • ETIM 6.0
    EC000902
  • UNSPSC 13.2
    39121410
  • ECLASS 4.1
    27141100
  • ECLASS 5.1
    27141100
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • 2 conductors with same cross section, solid min.
    0.2 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    2.5 mm²
  • Internal cylindrical gage
    A5
  • Min. tightening torque of the mounting screw:
    0.8 Nm
  • Insulating material
    PA
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • 2 conductors with same cross section, solid max.
    2.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Number of positions
    5
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • ECLASS 5.0
    27141100
  • UNSPSC 6.01
    30211811
  • UNSPSC 19.0
    39121410
  • ECLASS 4.0
    27141100
  • ECLASS 9.0
    27141126
  • Rated surge voltage
    4 kV
  • Mounting type
    Wall mounting
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • Terminal block mounting
    0.8 Nm ... 1 Nm
  • REACh SVHC
    Lead 7439-92-1
  • Maximum load current
    30 A (with 10 mm² conductor cross section)
  • ECLASS 10.0.1
    27141126
  • ECLASS 6.0
    27141100
  • ETIM 7.0
    EC000902
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Maximum power dissipation for nominal condition
    1.31 W
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • ETIM 3.0
    EC000901

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?