Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Push-in connection, number of connections: 12, number of positions: 6, cross section: 0.5 mm² - 10 mm², AWG: 20 - 8, width: 81.5 mm, height: 56.5 mm, color: gray, mounting type: Wall mount

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3069829 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • UNSPSC 13.2
    20122006
  • Number of levels
    1
  • Number of connections
    12
  • Maximum power dissipation for nominal condition
    1.31 W
  • Overvoltage category
    III
  • Note regarding shock protection
    When test disconnect plug is plugged in.
  • Maximum load current
    30 A (with 6 mm² conductor cross section)
  • Rated surge voltage
    4 kV
  • Insulating material group
    I
  • Open side panel
    No
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Tensile test result
    Test passed
  • Setpoint
    5 N
  • Result of voltage-drop test
    Test passed
  • Result of thermal test
    Test passed
  • Result of aging test
    Test passed
  • ASD level
    6.12 (m/s2)2/Hz
  • Shock form
    Half-sine
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Number of positions
    6
  • Potentials
    6
  • Flammability rating according to UL 94
    V0
  • Test surge voltage
    5 kV
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Back of the hand protection
    guaranteed
  • Result of flexion and pull-out test
    Test passed
  • Result of temperature-rise test
    Test passed
  • Note
    The measuring transducer block is replaced every 100 cycles.
  • Short-time current
    0.15 kA
  • Oscillation, broadband noise test result
    Test passed
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Acceleration
    30g
  • Shock duration
    18 ms
  • Nominal cross section
    6 mm²
  • Color
    gray
  • Insulating material
    PA
  • Nominal voltage UN
    400 V AC/DC
  • Result of surge voltage test
    Test passed
  • Static insulating material application in cold
    -60 °C
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of tight fit on support
    Test passed
  • Short circuit stability result
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Height
    56.5 mm
  • Conductor cross section short circuit testing
    4 mm²
  • Result of power-frequency withstand voltage test
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Test duration per axis
    5 h
  • Number of shocks per direction
    3
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Bending test rotation speed
    10 rpm
  • Bending test conductor cross section/weight
    0.5 mm² / 0.3 kg
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Conductor cross section solid max.
    10 mm²
  • Connection method
    Push-in connection
  • Conductor cross section solid min.
    1 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • Finger protection
    guaranteed
  • Bending test turns
    135
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Width
    81.5 mm
  • Connection in acc. with standard
    IEC 60947-7-1
  • Min. AWG conductor cross section, flexible
    20
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Max. AWG conductor cross section, flexible
    10
  • Connection cross sections directly pluggable
    1 mm² 10 mm²
  • Mounting type
    Wall mounting
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 7.0
    27141148
  • ETIM 4.0
    EC000902
  • Pitch
    8.2 mm
  • Connection
    1 level
  • Conductor cross section AWG min.
    20
  • Conductor cross section flexible max.
    6 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    1 mm²
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Length
    81 mm
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Internal cylindrical gage
    A5
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    1 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Stripping length
    12 mm
  • Conductor cross section AWG max.
    8
  • Conductor cross section flexible min.
    0.5 mm²
  • Shock test result
    Test passed
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 11.0
    27141148
  • ECLASS 5.1
    27141100
  • UNSPSC 19.0
    20122006
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • UNSPSC 21.0
    20122006
  • ECLASS 10.0.1
    27141148
  • ETIM 6.0
    EC002555
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1.5 mm²
  • ECLASS 6.0
    27141100
  • ECLASS 9.0
    27141148
  • UNSPSC 20.0
    20122006
  • UNSPSC 18.0
    20122006
  • ETIM 7.0
    EC002555
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?