3069819 Phoenix Contact Terminal Blocks
Part#:3069819
Manufacturer:Phoenix Contact
Category:Terminal Blocks
Product Lifecycle:Active
Get a quick Quote!
Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Screw connection, number of connections: 36, number of positions: 18, cross section: 0.2 mm² - 10 mm², AWG: 24 - 8, width: 179.3 mm, height: 58.6 mm, color: gray, mounting type: DIN rail m
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3069819 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Rated surge voltage 4 kV
- Color gray
- Maximum load current 30 A (with 10 mm² conductor cross section)
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Width 179.3 mm
- Connection 1 level
- Connection in acc. with standard IEC 60947-7-1
- Conductor cross section AWG max. 8
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.25 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 6 mm²
- 2 conductors with same cross section, stranded max. 2.5 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- Number of positions 18
- Number of levels 1
- Insulating material PA
- Maximum power dissipation for nominal condition 1.31 W
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Length 100 mm
- Tightening torque, min 1.5 Nm
- Tightening torque max 1.8 Nm
- Conductor cross section AWG min. 24
- Min. AWG conductor cross section, flexible 24
- 2 conductors with same cross section, solid max. 2.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 2.5 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- Permissible humidity (storage/transport) 30 % ... 70 %
- ECLASS 7.0 27141148
- ETIM 4.0 EC000902
- UNSPSC 18.0 20122006
- UNSPSC 20.0 20122006
- Potentials 18
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Height 58.6 mm
- Connection method Screw connection
- Conductor cross section flexible max. 10 mm²
- Mounting type DIN rail mounting
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- ECLASS 10.0.1 27141148
- ETIM 7.0 EC002555
- UNSPSC 19.0 20122006
- Number of connections 36
- Flammability rating according to UL 94 V0
- Nominal voltage UN 400 V AC/DC
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Height NS 35/15 69.3 mm
- Stripping length 10 mm
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm²
- 2 conductors with same cross section, stranded min. 0.2 mm²
- Nominal cross section 6 mm²
- Insulating material group I
- Open side panel No
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Pitch 8.2 mm
- Height NS 35/7,5 61.8 mm
- Conductor cross section solid max. 10 mm²
- Max. AWG conductor cross section, flexible 8
- 2 conductors with same cross section, solid min. 0.2 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.25 mm²
- Internal cylindrical gage A5
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 5.1 27141100
- ECLASS 6.0 27141100
- ETIM 6.0 EC002555
- Overvoltage category III
- Screw thread M4
- Conductor cross section flexible, with ferrule without plastic sleeve max. 6 mm²
- Test surge voltage 5 kV
- Ambient temperature (actuation) -5 °C ... 70 °C
- UNSPSC 13.2 20122006
- UNSPSC 21.0 20122006
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- ECLASS 11.0 27141148
- ECLASS 9.0 27141148
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?