Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Screw connection, number of connections: 30, number of positions: 15, cross section: 0.2 mm² - 10 mm², AWG: 24 - 8, width: 154.9 mm, height: 56.5 mm, color: gray, mounting type: NS 35/7,5,

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3069816 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Number of positions
    15
  • Potentials
    15
  • Insulating material
    PA
  • Flammability rating according to UL 94
    V0
  • Insulating material group
    I
  • Open side panel
    No
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Width
    154.9 mm
  • Height NS 35/7,5
    61.8 mm
  • Pitch
    8.2 mm
  • Tightening torque, min
    1.5 Nm
  • Conductor cross section AWG min.
    24
  • Conductor cross section solid max.
    10 mm²
  • Conductor cross section flexible max.
    10 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • 2 conductors with same cross section, solid min.
    0.2 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • Number of connections
    30
  • Color
    gray
  • Test surge voltage
    5 kV
  • Maximum power dissipation for nominal condition
    1.31 W
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Static insulating material application in cold
    -60 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Length
    100 mm
  • Height NS 35/15
    69.3 mm
  • Conductor cross section AWG max.
    8
  • Min. AWG conductor cross section, flexible
    24
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • 2 conductors with same cross section, solid max.
    2.5 mm²
  • 2 conductors with same cross section, stranded max.
    2.5 mm²
  • Internal cylindrical gage
    A5
  • Mounting type
    NS 35/7,5
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141126
  • ECLASS 6.0
    27141100
  • ECLASS 9.0
    27141126
  • Number of levels
    1
  • Nominal cross section
    6 mm²
  • Rated surge voltage
    4 kV
  • Overvoltage category
    III
  • Nominal voltage UN
    400 V AC/DC
  • Maximum load current
    30 A (with 10 mm² conductor cross section)
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height
    56.5 mm
  • Max. AWG conductor cross section, flexible
    8
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • 2 conductors with same cross section, stranded min.
    0.2 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    2.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 5.0
    27141100
  • ECLASS 7.0
    27141126
  • ETIM 7.0
    EC000902
  • UNSPSC 13.2
    39121410
  • ETIM 6.0
    EC000902
  • ETIM 4.0
    EC000897
  • UNSPSC 21.0
    39121410
  • UNSPSC 20.0
    39121410
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.25 mm²
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Screw thread
    M4
  • Conductor cross section solid min.
    0.2 mm²
  • Connection method
    Screw connection
  • Conductor cross section flexible min.
    0.2 mm²
  • Connection
    1 level
  • Connection in acc. with standard
    IEC 60947-7-1
  • Stripping length
    10 mm
  • Tightening torque max
    1.8 Nm
  • UNSPSC 18.0
    39121410
  • UNSPSC 19.0
    39121410
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 5.1
    27141100
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • ECLASS 10.0.1
    27141126

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?