3069815 Phoenix Contact Terminal Blocks
Part#:3069815
Manufacturer:Phoenix Contact
Category:Terminal Blocks
Product Lifecycle:Active
Get a quick Quote!
Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Screw connection, number of connections: 28, number of positions: 14, cross section: 0.2 mm² - 10 mm², AWG: 24 - 8, width: 146.7 mm, height: 56.5 mm, color: gray, mounting type: NS 35/7,5,
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3069815 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Number of levels 1
- Nominal cross section 6 mm²
- Insulating material PA
- Open side panel No
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Height NS 35/7,5 61.8 mm
- Stripping length 10 mm
- Conductor cross section AWG max. 8
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.25 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Internal cylindrical gage A5
- ECLASS 10.0.1 27141126
- ECLASS 6.0 27141100
- ETIM 6.0 EC000902
- Number of positions 14
- Number of connections 28
- Color gray
- Rated surge voltage 4 kV
- Overvoltage category III
- Maximum load current 30 A (with 10 mm² conductor cross section)
- Static insulating material application in cold -60 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Pitch 8.2 mm
- Connection in acc. with standard IEC 60947-7-1
- Min. AWG conductor cross section, flexible 24
- 2 conductors with same cross section, stranded min. 0.2 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.25 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- ECLASS 5.0 27141100
- ECLASS 7.0 27141126
- UNSPSC 13.2 39121410
- UNSPSC 21.0 39121410
- Maximum power dissipation for nominal condition 1.31 W
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Length 100 mm
- Screw thread M4
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible max. 10 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 6 mm²
- 2 conductors with same cross section, solid min. 0.2 mm²
- 2 conductors with same cross section, stranded max. 2.5 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ECLASS 11.0 27141126
- ETIM 4.0 EC000897
- UNSPSC 19.0 39121410
- Potentials 14
- Flammability rating according to UL 94 V0
- Test surge voltage 5 kV
- Nominal voltage UN 400 V AC/DC
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Width 146.7 mm
- Height NS 35/15 69.3 mm
- Connection method Screw connection
- Tightening torque, min 1.5 Nm
- Conductor cross section solid max. 10 mm²
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm²
- 2 conductors with same cross section, solid max. 2.5 mm²
- ECLASS 5.1 27141100
- Insulating material group I
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Height 56.5 mm
- Connection 1 level
- Tightening torque max 1.8 Nm
- Conductor cross section AWG min. 24
- Max. AWG conductor cross section, flexible 8
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 2.5 mm²
- Mounting type NS 35/7,5
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 9.0 27141126
- ETIM 7.0 EC000902
- UNSPSC 20.0 39121410
- Conductor cross section flexible, with ferrule with plastic sleeve max. 6 mm²
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Ambient temperature (actuation) -5 °C ... 70 °C
- Permissible humidity (storage/transport) 30 % ... 70 %
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- UNSPSC 18.0 39121410
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Get a quick Quote!
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?