Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Screw connection, number of connections: 10, number of positions: 5, cross section: 0.2 mm² - 10 mm², AWG: 24 - 8, width: 73.4 mm, height: 56.5 mm, color: gray, mounting type: NS 35/7,5, N
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3069806 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Mounting type NS 35/7,5
- Screw thread M4
- Tightening torque, min 1.5 Nm
- Number of positions 5
- Potentials 5
- Test surge voltage 5 kV
- Flammability rating according to UL 94 V0
- Insulating material group I
- Open side panel No
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Length 100 mm
- Height NS 35/7,5 61.8 mm
- Pitch 8.2 mm
- Connection 1 level
- Number of levels 1
- Nominal cross section 6 mm²
- Rated surge voltage 4 kV
- Insulating material PA
- Maximum power dissipation for nominal condition 1.31 W
- Nominal voltage UN 400 V AC/DC
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Width 73.4 mm
- Height NS 35/15 69.3 mm
- Height 56.5 mm
- Stripping length 10 mm
- Tightening torque max 1.8 Nm
- Conductor cross section flexible max. 10 mm²
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm²
- 2 conductors with same cross section, solid max. 2.5 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.25 mm²
- 2 conductors with same cross section, solid min. 0.2 mm²
- 2 conductors with same cross section, stranded max. 2.5 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- Connection in acc. with standard IEC 60947-7-1
- Conductor cross section AWG min. 24
- Conductor cross section AWG max. 8
- Max. AWG conductor cross section, flexible 8
- 2 conductors with same cross section, stranded min. 0.2 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 2.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Internal cylindrical gage A5
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.25 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- Ambient temperature (assembly) -5 °C ... 70 °C
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 5.0 27141100
- ECLASS 7.0 27141126
- ETIM 4.0 EC000897
- ETIM 7.0 EC000902
- ETIM 6.0 EC000902
- UNSPSC 19.0 39121410
- UNSPSC 21.0 39121410
- Number of connections 10
- Overvoltage category III
- Maximum load current 30 A (with 10 mm² conductor cross section)
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Min. AWG conductor cross section, flexible 24
- Connection method Screw connection
- Color gray
- Static insulating material application in cold -60 °C
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Conductor cross section flexible, with ferrule with plastic sleeve max. 6 mm²
- Conductor cross section solid max. 10 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve max. 6 mm²
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Conductor cross section solid min. 0.2 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- ECLASS 5.1 27141100
- UNSPSC 18.0 39121410
- ECLASS 11.0 27141126
- ECLASS 9.0 27141126
- UNSPSC 13.2 39121410
- UNSPSC 20.0 39121410
- ECLASS 10.0.1 27141126
- ECLASS 6.0 27141100
- Permissible humidity (storage/transport) 30 % ... 70 %
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?