Test terminal strip, nom. voltage: 400 V AC/DC, connection method: Screw connection, number of connections: 48, number of positions: 24, cross section: 0.2 mm² - 10 mm², AWG: 24 - 8, width: 228.2 mm, height: 56.5 mm, color: gray, mounting type: Wall mount

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3069803 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Connection
    1 level
  • Number of connections
    48
  • Flammability rating according to UL 94
    V0
  • Rated surge voltage
    4 kV
  • Open side panel
    No
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Tensile test result
    Test passed
  • Result of temperature-rise test
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Result of thermal test
    Test passed
  • Shock form
    Half-sine
  • Insulating material
    PA
  • Test surge voltage
    5 kV
  • Maximum power dissipation for nominal condition
    1.31 W
  • Result of power-frequency withstand voltage test
    Test passed
  • Number of levels
    1
  • Nominal cross section
    6 mm²
  • Insulating material group
    I
  • Maximum load current
    30 A (with 10 mm² conductor cross section)
  • Result of surge voltage test
    Test passed
  • Result of flexion and pull-out test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Result of tight fit on support
    Test passed
  • Oscillation, broadband noise test result
    Test passed
  • Test duration per axis
    5 h
  • Number of positions
    24
  • Color
    gray
  • Overvoltage category
    III
  • Nominal voltage UN
    400 V AC/DC
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Bending test conductor cross section/weight
    0.2 mm² / 0.2 kg
  • Result of voltage-drop test
    Test passed
  • Short circuit stability result
    Test passed
  • Conductor cross section short circuit testing
    4 mm²
  • Result of aging test
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • ETIM 4.0
    EC000902
  • ETIM 7.0
    EC002555
  • Potentials
    24
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 6.0
    27141100
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Tightening torque, min
    1.5 Nm
  • Conductor cross section solid max.
    10 mm²
  • UNSPSC 20.0
    20122006
  • Conductor cross section flexible min.
    0.2 mm²
  • Conductor cross section flexible max.
    10 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.25 mm²
  • 2 conductors with same cross section, solid min.
    0.2 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • ECLASS 10.0.1
    27141148
  • Pitch
    8.2 mm
  • Tightening torque max
    1.8 Nm
  • Conductor cross section AWG max.
    8
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.25 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • 2 conductors with same cross section, stranded min.
    0.2 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    2.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 5.1
    27141100
  • ETIM 6.0
    EC002555
  • UNSPSC 21.0
    20122006
  • Conductor cross section AWG min.
    24
  • Max. AWG conductor cross section, flexible
    8
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • 2 conductors with same cross section, stranded max.
    2.5 mm²
  • Mounting type
    Wall mounting
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 7.0
    27141148
  • ECLASS 9.0
    27141148
  • UNSPSC 18.0
    20122006
  • Height
    56.5 mm
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Min. AWG conductor cross section, flexible
    24
  • ASD level
    6.12 (m/s2)2/Hz
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Width
    228.2 mm
  • Number of shocks per direction
    3
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Connection method
    Screw connection
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Acceleration
    30g
  • Shock duration
    18 ms
  • Bending test turns
    135
  • Setpoint
    5 N
  • Short-time current
    500 A
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Note
    25 pos.
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Shock test result
    Test passed
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Length
    81 mm
  • Stripping length
    12 mm
  • UNSPSC 13.2
    20122006
  • UNSPSC 19.0
    20122006
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Connection in acc. with standard
    IEC 60947-7-1
  • 2 conductors with same cross section, solid max.
    2.5 mm²
  • ECLASS 11.0
    27141148
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Internal cylindrical gage
    A5
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Screw thread
    M4
  • Conductor cross section solid min.
    0.2 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.25 mm²
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?