Test terminal strip, VDE coded type E7, A detailed circuit diagram can be found under Miscellaneous Downloads, nom. voltage: 400 V AC/DC, connection method: Push-in connection, number of connections: 14, number of positions: 7, cross section: 0.5 mm² - 10

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3069438 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Conductor cross section flexible min.
    0.5 mm²
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • Number of positions
    7
  • Potentials
    7
  • Number of levels
    1
  • Nominal cross section
    6 mm²
  • Rated surge voltage
    4 kV
  • Overvoltage category
    III
  • Open side panel
    No
  • Back of the hand protection
    guaranteed
  • Result of tight fit on support
    Test passed
  • Result of voltage-drop test
    Test passed
  • Bending test conductor cross section/weight
    0.5 mm² / 0.3 kg
  • Short circuit stability result
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Short-time current
    0.15 kA
  • Oscillation, broadband noise test result
    Test passed
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • ASD level
    6.12 (m/s2)2/Hz
  • Test duration per axis
    5 h
  • Shock test result
    Test passed
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Shock duration
    18 ms
  • Static insulating material application in cold
    -60 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Width
    90.2 mm
  • Length
    100 mm
  • Height
    56.5 mm
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1.5 mm²
  • Internal cylindrical gage
    A5
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • Result of flexion and pull-out test
    Test passed
  • Bending test turns
    135
  • Tensile test result
    Test passed
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • Conductor cross section short circuit testing
    4 mm²
  • Result of aging test
    Test passed
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    1 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Min. tightening torque of the mounting screw:
    0.8 Nm
  • ECLASS 10.0.1
    27141126
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ECLASS 9.0
    27141126
  • ECLASS 7.0
    27141126
  • Setpoint
    5 N
  • Result of temperature-rise test
    Test passed
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    6 mm²
  • Min. AWG conductor cross section, flexible
    20
  • Max. tightening torque of the mounting screw:
    1 Nm
  • Connection cross sections directly pluggable
    1 mm² 10 mm²
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • REACh SVHC
    Lead 7439-92-1
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141126
  • ECLASS 5.1
    27141100
  • ECLASS 6.0
    27141100
  • UNSPSC 18.0
    39121410
  • UNSPSC 20.0
    39121410
  • UNSPSC 19.0
    39121410
  • Mounting type
    Wall mounting
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of power-frequency withstand voltage test
    Test passed
  • Note regarding shock protection
    When test disconnect plug is plugged in.
  • Test spectrum
    Service life test category 2, bogie-mounted
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    1 mm²
  • Finger protection
    guaranteed
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    6 mm²
  • Acceleration
    30g
  • Shock form
    Half-sine
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Conductor cross section solid max.
    10 mm²
  • Stripping length
    12 mm
  • Conductor cross section flexible max.
    6 mm²
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Pitch
    8.2 mm
  • Plate thickness
    1 mm ... 4 mm
  • Conductor cross section AWG min.
    20
  • Result of thermal test
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 250 Hz
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Connection in acc. with standard
    IEC 60947-7-1
  • Conductor cross section solid min.
    1 mm²
  • Max. AWG conductor cross section, flexible
    10
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Number of shocks per direction
    3
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Connection method
    Push-in connection
  • Conductor cross section AWG max.
    8
  • Maximum load current
    30 A (with 6 mm² conductor cross section)
  • Result of surge voltage test
    Test passed
  • Note
    The measuring transducer block is replaced every 100 cycles.
  • Number of connections
    14
  • Flammability rating according to UL 94
    V0
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Bending test rotation speed
    10 rpm
  • Color
    gray
  • Insulating material group
    I
  • Insulating material
    PA
  • Terminal block mounting
    0.8 Nm ... 1 Nm
  • Test surge voltage
    5 kV
  • Nominal voltage UN
    400 V AC/DC
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • ETIM 4.0
    EC000897
  • ETIM 6.0
    EC000902
  • Maximum power dissipation for nominal condition
    1.31 W
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • UNSPSC 13.2
    39121410
  • ECLASS 5.0
    27141100
  • Connection
    1 level
  • ETIM 7.0
    EC000902
  • UNSPSC 21.0
    39121410

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?