3069429 Phoenix Contact Terminal Blocks
Part#:3069429
Manufacturer:Phoenix Contact
Category:Terminal Blocks
Product Lifecycle:Active
Get a quick Quote!
Test terminal strip, VDE coded type B19, A detailed circuit diagram can be found under Miscellaneous Downloads, nom. voltage: 400 V AC/DC, connection method: Screw connection, number of connections: 38, number of positions: 19, cross section: 0.2 mm² - 10
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3069429 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Nominal cross section 6 mm²
- Note A detailed circuit diagram can be found under Miscellaneous Downloads
- Insulating material PA
- Rated surge voltage 4 kV
- Maximum load current 30 A (with 10 mm² conductor cross section)
- Test surge voltage 5 kV
- Potentials 19
- Color gray
- Insulating material group I
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Width 187.5 mm
- Height NS 35/15 69.3 mm
- Screw thread M4
- Tightening torque max 1.8 Nm
- Min. AWG conductor cross section, flexible 24
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 6 mm²
- 2 conductors with same cross section, stranded max. 2.5 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- Ambient temperature (assembly) -5 °C ... 70 °C
- Number of positions 19
- Nominal voltage UN 400 V AC/DC
- Maximum power dissipation for nominal condition 1.31 W
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
- Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Length 100 mm
- Height NS 35/7,5 61.8 mm
- Pitch 8.2 mm
- Max. AWG conductor cross section, flexible 8
- Conductor cross section solid max. 10 mm²
- Conductor cross section flexible max. 10 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.25 mm²
- Ambient temperature (actuation) -5 °C ... 70 °C
- Number of levels 1
- Number of connections 38
- Flammability rating according to UL 94 V0
- Overvoltage category III
- Open side panel No
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Height 56.5 mm
- Connection method Screw connection
- ECLASS 5.0 27141100
- Connection 1 level
- Stripping length 10 mm
- Conductor cross section solid min. 0.2 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 2.5 mm²
- ECLASS 11.0 27141126
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Internal cylindrical gage A5
- ECLASS 5.1 27141100
- UNSPSC 13.2 39121410
- ETIM 4.0 EC000897
- Connection in acc. with standard IEC 60947-7-1
- 2 conductors with same cross section, stranded min. 0.2 mm²
- ECLASS 7.0 27141126
- UNSPSC 19.0 39121410
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.25 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- ETIM 7.0 EC000902
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- 2 conductors with same cross section, solid min. 0.2 mm²
- Mounting type NS 35/7,5
- Tightening torque, min 1.5 Nm
- 2 conductors with same cross section, solid max. 2.5 mm²
- ECLASS 10.0.1 27141126
- ECLASS 6.0 27141100
- UNSPSC 20.0 39121410
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Conductor cross section AWG min. 24
- Conductor cross section flexible, with ferrule without plastic sleeve max. 6 mm²
- Permissible humidity (storage/transport) 30 % ... 70 %
- Conductor cross section AWG max. 8
- Surface flammability NFPA 130 (ASTM E 162) passed
- ETIM 6.0 EC000902
- ECLASS 9.0 27141126
- UNSPSC 18.0 39121410
- UNSPSC 21.0 39121410
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm²
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?