Bolt connection terminal block, Note: the BE-RT... path extension is to be used for non-insulated cable lugs (see accessories)., nom. voltage: 1000 V, nominal current: 41 A, connection method: Bolt connection, number of connections: 2, width: 16.3 mm, col

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3049521 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • ETIM 2.0
    EC000897
  • UNSPSC 11
    39121410
  • UNSPSC 13.2
    39121410
  • ECLASS 7.0
    27141120
  • Open side panel
    Yes
  • Nominal voltage UN
    1000 V
  • Result of power-frequency withstand voltage test
    Test passed
  • Setpoint
    5 N
  • Result of temperature-rise test
    Test passed
  • Short-time current
    0.72 kA
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Insulating material group
    I
  • Result of surge voltage test
    Test passed
  • Power frequency withstand voltage setpoint
    2.2 kV
  • Result of voltage-drop test
    Test passed
  • Test duration per axis
    5 h
  • Shock form
    Half-sine
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Length
    66 mm
  • Width
    16.3 mm
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Static insulating material application in cold
    -60 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    28 MJ/kg
  • Flammability rating according to UL 94
    V0
  • Nominal current IN
    41 A
  • Maximum load current
    41 A (with 6 mm² conductor cross section)
  • Result of tight fit on support
    Test passed
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Shock test result
    Test passed
  • Shock duration
    30 ms
  • Nominal cross section
    6 mm²
  • Degree of pollution
    3
  • Short circuit stability result
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Test specification, oscillation, broadband noise
    DIN EN 50155 (VDE 0115-200):2008-03
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Potentials
    1
  • Maximum power dissipation for nominal condition
    1.31 W
  • Conductor cross section short circuit testing
    6 mm²
  • Number of connections
    2
  • Insulating material
    PA
  • Tight fit on carrier
    NS 35
  • Requirement temperature-rise test
    Increase in temperature ≤ 45 K
  • ASD level
    1.857 (m/s2)2/Hz
  • Test directions
    X-, Y- and Z-axis (pos. and neg.)
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Note
    Note: the BE-RT... path extension is to be used for non-insulated cable lugs (see accessories).
  • Color
    gray
  • Rated surge voltage
    8 kV
  • Result of thermal test
    Test passed
  • Test frequency
    f1 = 5 Hz to f2 = 150 Hz
  • Acceleration
    5g
  • Test specification, shock test
    DIN EN 50155 (VDE 0115-200):2008-03
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Connection
    1 level
  • Connection in acc. with standard
    CUL
  • Number of levels
    1
  • Overvoltage category
    III
  • Oscillation, broadband noise test result
    Test passed
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 35/7,5
    49.9 mm
  • Connection method
    Bolt connection
  • ECLASS 4.1
    27141100
  • End cover width
    2.2 mm
  • Min. cross section for cable lug connection
    1 mm²
  • Bolt diameter
    5 mm
  • Tightening torque max
    3 Nm
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • ETIM 3.0
    EC000897
  • ETIM 6.0
    EC000897
  • Max. cross section for cable lug connection
    6 mm²
  • Stripping length
    The stripping length depends on the specification provided by the cable lug manufacturer.
  • Screw thread
    M5
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141120
  • ECLASS 6.0
    27141100
  • ETIM 7.0
    EC000897
  • UNSPSC 19.0
    39121410
  • UNSPSC 18.0
    39121410
  • Cable lug width, max.
    10 mm
  • Height NS 35/15
    57.4 mm
  • Cable lug connection according to standard
    DIN 46237:1970-07
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 4.0
    27141100
  • ETIM 4.0
    EC000897
  • UNSPSC 21.0
    39121410
  • AWG max
    10
  • Hole diameter, min.
    5.3 mm
  • ECLASS 10.0.1
    27141120
  • ECLASS 5.1
    27141100
  • UNSPSC 7.0901
    39121410
  • UNSPSC 12.01
    39121410
  • AWG min
    16
  • Tightening torque, min
    2.5 Nm
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 5.0
    27141100
  • ECLASS 9.0
    27141120
  • UNSPSC 20.0
    39121410
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • UNSPSC 6.01
    30211811

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?