3048027 Phoenix Contact Terminal Blocks
Part#:3048027
Manufacturer:Phoenix Contact
Category:Terminal Blocks
Product Lifecycle:Active
Get a quick Quote!
Component terminal block, for installing components that can be individually selected, nom. voltage: 500 V, nominal current: 32 A, connection method: Screw connection, cross section: 0.2 mm² - 4 mm², AWG: 24 - 12, length: 56 mm, width: 6.2 mm, color: gray
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3048027 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Note Maximum width of components to be soldered in: 5 mm
- Color gray
- Insulating material PA
- Maximum load current 32 A (with 4 mm² conductor cross section)
- Maximum power dissipation for nominal condition 1.02 W (the value is multiplied when connecting multiple levels)
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Height NS 35/15 69.5 mm
- Height NS 32 67 mm
- Conductor cross section flexible, with ferrule without plastic sleeve max. 4 mm²
- 2 conductors with same cross section, stranded max. 1.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 1.5 mm²
- Tightening torque max 0.8 Nm
- REACh SVHC Lead 7439-92-1
- ECLASS 10.0.1 27141127
- ECLASS 5.1 27141100
- ETIM 3.0 EC000897
- UNSPSC 11 39121410
- Flammability rating according to UL 94 V0
- Connection in acc. with standard IEC 60947-7-1
- Number of positions 2
- Number of levels 2
- Overvoltage category III
- Insulating material group I
- Open side panel Yes
- Static insulating material application in cold -60 °C
- Height NS 35/7,5 62 mm
- Conductor cross section flexible max. 4 mm²
- 2 conductors with same cross section, solid max. 1.5 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Internal cylindrical gage A4
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 11.0 27141127
- ECLASS 9.0 27141127
- ETIM 4.0 EC000897
- Nominal cross section 4 mm²
- Degree of pollution 3
- Nominal voltage UN 500 V (Data is based on the dielectric strength of adjacent terminal blocks or of the DINg rail.)
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Length 56 mm
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section AWG max. 12
- 2 conductors with same cross section, stranded min. 0.2 mm²
- Connection method Screw connection
- Tightening torque, min 0.6 Nm
- Permissible humidity (storage/transport) 30 % ... 70 %
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 7.0 27141127
- ETIM 2.0 EC000897
- ETIM 7.0 EC000903
- UNSPSC 20.0 39121410
- Number of connections 4
- Rated surge voltage 6 kV
- Nominal current IN 32 A
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Surface flammability NFPA 130 (ASTM E 162) passed
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- End cover width 2.5 mm
- Conductor cross section solid max. 4 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.25 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.25 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1.5 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 4.0 27141100
- ECLASS 4.1 27141100
- ETIM 6.0 EC000903
- UNSPSC 7.0901 39121410
- UNSPSC 12.01 39121410
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Width 6.2 mm
- Conductor cross section AWG min. 24
- Conductor cross section flexible, with ferrule with plastic sleeve max. 2.5 mm²
- 2 conductors with same cross section, solid min. 0.2 mm²
- Stripping length 8 mm
- Screw thread M3
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- ECLASS 5.0 27141100
- ECLASS 6.0 27141100
- UNSPSC 6.01 30211811
- UNSPSC 19.0 39121410
- UNSPSC 13.2 39121410
- UNSPSC 21.0 39121410
- UNSPSC 18.0 39121410
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?