3044641 Phoenix Contact Terminal Blocks

3044641 on Power Resource International
Phoenix Contact

Part#:3044641

Manufacturer:Phoenix Contact

Category:Terminal Blocks

Product Lifecycle:Active

Get a quick Quote!

Knife disconnect terminal block, With test socket screws for insertion of test plugs, nom. voltage: 400 V, nominal current: 22 A, connection method: Screw connection, cross section: 0.14 mm² - 4 mm², AWG: 26 - 12, length: 69.9 mm, width: 5.2 mm, color: bl

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 3044641 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Nominal cross section
    2.5 mm²
  • Overvoltage category
    III
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Static insulating material application in cold
    -60 °C
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Height NS 35/7,5
    65 mm
  • Conductor cross section AWG min.
    26
  • 2 conductors with same cross section, stranded min.
    0.14 mm²
  • Connection method
    Screw connection
  • Rated surge voltage
    6 kV
  • Connection in acc. with standard
    IEC 60947-7-1
  • Open side panel
    Yes
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Width
    5.2 mm
  • Conductor cross section solid min.
    0.14 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.14 mm²
  • 2 conductors with same cross section, solid max.
    1.5 mm²
  • 2 conductors with same cross section, stranded max.
    1.5 mm²
  • Screw thread
    M3
  • Tightening torque, min
    0.5 Nm
  • ECLASS 10.0.1
    27141126
  • ECLASS 5.1
    27141100
  • ECLASS 6.0
    27141100
  • UNSPSC 21.0
    39121410
  • Number of levels
    2
  • Number of connections
    4
  • Insulating material
    PA
  • Maximum load current
    24 A (in case of a 4 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.)
  • Nominal voltage UN
    400 V
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Height
    64.4 mm
  • Conductor cross section solid max.
    4 mm²
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    2.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum
    1.5 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • Internal cylindrical gage
    A3
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 11.0
    27141126
  • ETIM 6.0
    EC000902
  • UNSPSC 18.0
    39121410
  • Flammability rating according to UL 94
    V0
  • Insulating material group
    I
  • Maximum power dissipation for nominal condition
    0.77 W (the value is multiplied when connecting multiple levels)
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Length
    69.9 mm
  • Height NS 35/15
    72.5 mm
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    2.5 mm²
  • Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum
    0.14 mm²
  • Tightening torque max
    0.6 Nm
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 9.0
    27141126
  • UNSPSC 20.0
    39121410
  • Color
    blue
  • Degree of pollution
    3
  • Nominal current IN
    22 A
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • End cover width
    2.2 mm
  • Conductor cross section flexible min.
    0.14 mm²
  • Conductor cross section AWG max.
    12
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.14 mm²
  • 2 conductors with same cross section, solid min.
    0.14 mm²
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1.5 mm²
  • Stripping length
    9 mm
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 125°C)
  • Ambient temperature (actuation)
    -5 °C ... 70 °C
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 7.0
    27141126
  • ETIM 7.0
    EC000902
  • UNSPSC 13.2
    39121410
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 5.0
    27141100
  • UNSPSC 19.0
    39121410

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?

Recommended parts