3036220 Phoenix Contact Terminal Blocks

3036220 on Power Resource International
Phoenix Contact

Part#:3036220

Manufacturer:Phoenix Contact

Category:Terminal Blocks

Product Lifecycle:Active

Product description

Installation terminal block, Spring-cage connection, cross section: 0.08 mm² - 6 mm², AWG: 28 - 10, width: 6.2 mm, color: blue, mounting type: NS 35/7,5, NS 35/15

Product Details

  • Insulating material
    PA
  • Degree of pollution
    3
  • Connection in acc. with standard
    IEC 60947-7-1
  • Finger protection
    guaranteed
  • Result of flexion and pull-out test
    Test passed
  • Bending test conductor cross section/weight
    0.08 mm² / 0.1 kg
  • Tensile test result
    Test passed
  • Conductor cross section short circuit testing
    6 mm²
  • Result of aging test
    Test passed
  • Color
    blue
  • Rated surge voltage
    6 kV
  • Back of the hand protection
    guaranteed
  • Result of power-frequency withstand voltage test
    Test passed
  • Bending test turns
    135
  • Setpoint
    1 N
  • Short circuit stability result
    Test passed
  • Proof of thermal characteristics (needle flame) effective duration
    30 s
  • Surface flammability NFPA 130 (ASTM E 162)
    passed
  • Fire protection for rail vehicles (DIN EN 45545-2) R26
    HL 1 - HL 3
  • Height NS 35/7,5
    43 mm
  • Conductor cross section flexible min.
    0.08 mm²
  • Conductor cross section AWG max.
    10
  • Conductor cross section flexible, with ferrule with plastic sleeve max.
    4 mm²
  • Nominal cross section
    4 mm²
  • Overvoltage category
    III
  • Open side panel
    Yes
  • Result of the test for mechanical stability of terminal points (5 x conductor connection)
    Test passed
  • Result of tight fit on support
    Test passed
  • Tight fit on carrier
    NS 35
  • Short-time current
    0.72 kA
  • Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))
    125 °C
  • Specific optical density of smoke NFPA 130 (ASTM E 662)
    passed
  • Smoke gas toxicity NFPA 130 (SMP 800C)
    passed
  • Length
    66 mm
  • Conductor cross section solid max.
    6 mm²
  • Conductor cross section flexible, with ferrule without plastic sleeve max.
    4 mm²
  • Operating temperature
    -60 °C ... 105 °C (max. short-term operating temperature 130°C)
  • China RoHS
    Environmentally friendly use period: unlimited = EFUP-e
  • ECLASS 5.0
    27141100
  • ECLASS 9.0
    27141125
  • UNSPSC 6.01
    30211811
  • UNSPSC 11
    39121410
  • UNSPSC 18.0
    39121410
  • Number of levels
    1
  • Flammability rating according to UL 94
    V0
  • Insulating material group
    I
  • Shock protection test specification
    DIN EN 50274 (VDE 0660-514):2002-11
  • Surge voltage test setpoint
    7.3 kV
  • Power frequency withstand voltage setpoint
    1.89 kV
  • Tractive force setpoint
    80 N
  • Requirements, voltage drop
    ≤ 3.2 mV
  • Ageing test for screwless modular terminal block temperature cycles
    192
  • Static insulating material application in cold
    -60 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R22
    HL 1 - HL 3
  • Fire protection for rail vehicles (DIN EN 45545-2) R23
    HL 1 - HL 3
  • End cover width
    2.2 mm
  • Conductor cross section flexible max.
    4 mm²
  • Conductor cross section flexible, with ferrule with plastic sleeve min.
    0.14 mm²
  • Connection method
    Spring-cage connection
  • Permissible humidity (storage/transport)
    30 % ... 70 %
  • ECLASS 5.1
    27141100
  • ETIM 3.0
    EC001329
  • UNSPSC 7.0901
    39121410
  • UNSPSC 21.0
    39121410
  • Number of connections
    2
  • Maximum load current
    41 A (with 6 mm² conductor cross section)
  • Maximum power dissipation for nominal condition
    1.02 W
  • Nominal current IN
    32 A (with 6 mm² conductor cross section)
  • Nominal voltage UN
    400 V
  • Result of surge voltage test
    Test passed
  • Bending test rotation speed
    10 rpm
  • Conductor cross section tensile test
    6 mm²
  • Result of voltage-drop test
    Test passed
  • Result of temperature-rise test
    Test passed
  • Result of thermal test
    Test passed
  • Relative insulation material temperature index (Elec., UL 746 B)
    130 °C
  • Fire protection for rail vehicles (DIN EN 45545-2) R24
    HL 1 - HL 3
  • Height NS 35/15
    50.5 mm
  • Conductor cross section flexible, with ferrule without plastic sleeve min.
    0.14 mm²
  • Stripping length
    10 mm
  • Ambient temperature (storage/transport)
    -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
  • ECLASS 4.1
    27141100
  • ETIM 2.0
    EC001329
  • ETIM 6.0
    EC001329
  • UNSPSC 13.2
    39121410
  • UNSPSC 20.0
    39121410
  • Calorimetric heat release NFPA 130 (ASTM E 1354)
    27,5 MJ/kg
  • Width
    6.2 mm
  • Conductor cross section solid min.
    0.08 mm²
  • Conductor cross section AWG min.
    28
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum
    0.5 mm²
  • ECLASS 10.0.1
    27141125
  • ECLASS 6.0
    27141100
  • ETIM 4.0
    EC001329
  • UNSPSC 19.0
    39121410
  • Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum
    1 mm²
  • Ambient temperature (assembly)
    -5 °C ... 70 °C
  • ECLASS 11.0
    27141125
  • ECLASS 4.0
    27141100
  • ECLASS 7.0
    27141125
  • ETIM 7.0
    EC001329
  • UNSPSC 12.01
    39121410

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

Relevant products

What can I help you find today?

Recommended parts