Feed-through terminal block, nom. voltage: 690 V, nominal current: 24 A, connection method: Screw connection, number of connections: 2, cross section: 0.2 mm² - 4 mm², AWG: 24 - 12, width: 6.2 mm, color: blue, mounting type: NS 35/7,5, NS 35/15
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Terminal Blocks that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 3001048 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Color blue
- Degree of pollution 3
- Shock protection test specification IEC 60529:2001-02
- Power frequency withstand voltage setpoint 1.89 kV
- Bending test rotation speed 10 rpm
- Tight fit on carrier NS 32/NS 35
- Conductor cross section short circuit testing 4 mm²
- Proof of thermal characteristics (needle flame) effective duration 30 s
- Surface flammability NFPA 130 (ASTM E 162) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
- End cover width 1.5 mm
- Connection method Screw connection
- Conductor cross section solid max. 4 mm²
- Potentials 1
- Rated surge voltage 8 kV
- Nominal current IN 24 A
- Back of the hand protection guaranteed
- Result of flexion and pull-out test Test passed
- Tensile test result Test passed
- Requirement temperature-rise test Increase in temperature ≤ 45 K
- Result of thermal test Test passed
- Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
- Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
- Height NS 35/7,5 42 mm
- Tightening torque, min 0.6 Nm
- Conductor cross section AWG max. 12
- Min. AWG conductor cross section, flexible 24
- 2 conductors with same cross section, solid max. 1 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum 1 mm²
- Operating temperature -60 °C ... 105 °C (max. short-term operating temperature 130°C)
- ECLASS 4.1 27141100
- ECLASS 9.0 27141120
- ETIM 7.0 EC000897
- UNSPSC 12.01 39121410
- UNSPSC 18.0 39121410
- Insulating material PA
- Nominal voltage UN 690 V
- Finger protection guaranteed
- Result of the test for mechanical stability of terminal points (5 x conductor connection) Test passed
- Setpoint 1 N
- Short circuit stability result Test passed
- Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
- Smoke gas toxicity NFPA 130 (SMP 800C) passed
- Width 6.2 mm
- Height NS 35/15 49.5 mm
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG min. 30
- Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²
- 2 conductors with same cross section, stranded max. 1 mm²
- Connection in acc. with standard CSA
- Permissible humidity (storage/transport) 30 % ... 70 %
- Ambient temperature (actuation) -5 °C ... 70 °C
- ECLASS 10.0.1 27141120
- ECLASS 4.0 27141100
- ETIM 4.0 EC000897
- UNSPSC 11 39121410
- UNSPSC 20.0 39121410
- Number of levels 1
- Flammability rating according to UL 94 V0
- Insulating material group I
- Result of surge voltage test Test passed
- Bending test conductor cross section/weight 0.2 mm² / 0.2 kg
- Result of voltage-drop test Test passed
- Short-time current 0.48 kA
- Static insulating material application in cold -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
- Height NS 32 47 mm
- Screw thread M3
- Max. AWG conductor cross section, flexible 14
- 2 conductors with same cross section, solid min. 0.2 mm²
- 2 conductors with same cross section, stranded min. 0.25 mm²
- Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum 0.25 mm²
- Ambient temperature (assembly) -5 °C ... 70 °C
- ECLASS 11.0 27141120
- ECLASS 5.1 27141100
- ECLASS 6.0 27141100
- ETIM 3.0 EC000897
- UNSPSC 13.2 39121410
- UNSPSC 19.0 39121410
- Number of connections 2
- Overvoltage category III
- Open side panel Yes
- Result of power-frequency withstand voltage test Test passed
- Bending test turns 135
- Result of tight fit on support Test passed
- Result of temperature-rise test Test passed
- Relative insulation material temperature index (Elec., UL 746 B) 130 °C
- Specific optical density of smoke NFPA 130 (ASTM E 662) passed
- Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
- Length 42.5 mm
- Stripping length 7 mm
- Tightening torque max 0.8 Nm
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve min. 0.25 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum 1.5 mm²
- Internal cylindrical gage A3
- REACh SVHC Lead 7439-92-1
- ECLASS 5.0 27141100
- ETIM 2.0 EC000897
- UNSPSC 6.01 30211811
- Conductor cross section flexible max. 2.5 mm²
- Conductor cross section flexible, with ferrule with plastic sleeve max. 1 mm²
- Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum 0.5 mm²
- Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 7.0 27141120
- ETIM 6.0 EC000897
- UNSPSC 7.0901 39121410
- UNSPSC 21.0 39121410
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.