Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal input, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2924809 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 35 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of protection IP20 (not assessed by UL)
- Sensor types (RTD) that can be used Pt, Ni, Cu sensors: 2, 3, 4-wire
- Vibration (operation) 5g, accordance to IEC 60068-2-6
- Load/output load voltage output ≥ 10 kΩ
- Max. voltage output signal ± 11 V
- Load/output load current output ≤ 600 Ω (at 20 mA)
- Contact material AgSnO2, hard gold-plated
- Supply voltage range 24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
- Mechanical service life 1x 105 cycles
- Conductor cross section solid 0.2 mm² ... 1.5 mm²
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Interference emission EN 61000-6-4
- Electrical isolation 4-way, between input/output/power supply/switching output
- Max. output power Po 11 mW
- Additional text mixed circuit
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Depth 114.5 mm
- Typical deviation from the measuring range final value 2 %
- UL, USA/Canada UL 508 Listed
- DNV GL-Vibration A
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- REACh SVHC Lead 7439-92-1
- Height 116 mm
- Maximum altitude ≤ 2000 m
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Sensor types that can be used (TC) B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
- Input signal range -1000 mV ... 1000 mV
- Max. current output signal 22 mA
- Output name Relay output
- Housing material PA 6.6-FR
- Max. internal capacitance Ci 44 nF
- Max. external capacitance Co 21 µF
- Noise emission EN 61000-6-4
- DNV GL-EMC A
- Stripping length 8 mm
- Maximum transmission error 0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
- Degree of pollution 2
- Color gray
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Max. output current Io 7.4 mA
- Standards/regulations EN 61000-4-6
- DNV GL-Humidity B
- Temperature B
- ECLASS 10.0.1 27210129
- ECLASS 5.1 27200206
- ETIM 4.0 EC001596
- UNSPSC 6.01 30211506
- UNSPSC 21.0 41112105
- Permissible humidity (operation) typ. 5 % ... 95 % (non-condensing)
- Shock 15g, according to IEC 60068-2-27
- Temperature measuring range -250 °C ... 2500 °C (Range depending on the sensor type)
- Current output signal 4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
- Potentiometer resistance range 0 Ω ... 50 kΩ
- Behavior in the event of a sensor error according to NE 43 or freely configurable
- Contact type 3 changeover contacts
- Maximum switching voltage 250 V AC (250 V DC)
- Power consumption < 2.4 W
- Conductor cross section AWG 24 ... 16
- Status display Green LED (supply voltage, PWR)
- Overvoltage category II
- Designation INMETRO
- Max. output voltage Uo 6 V
- Ambient temperature (operation) -20 °C ... 65 °C
- Maximum temperature coefficient 0.01 %/K
- Step response (0–99%) typ. 1000 ms (With SIL)
- Electromagnetic compatibility Conformance with EMC directive
- Rated insulation voltage 300 Vrms
- Max. internal inductance Li negligible
- Safety-related maximum voltage Um 253 V AC/DC
- IECEx [Ex ia Ga] IIC
- DNV GL-Temperature B
- Certificate DNV 18.0143 X
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 6.0 27371500
- ECLASS 5.0 27371500
- UNSPSC 7.0901 39121008
- UNSPSC 13.2 39121008
- UNSPSC 18.0 41112105
- ECLASS 4.1 27210107
- UNSPSC 12.01 39121008
- UNSPSC 20.0 41112105
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Identification [Ex ia Ga] IIC
- ECLASS 11.0 27210129
- ECLASS 4.0 27210107
- Typical current consumption < 100 mA (24 V DC)
- Group IIC
- EMC A
- ECLASS 7.0 27371503
- ETIM 7.0 EC002568
- UNSPSC 19.0 41112105
- Connection method Push-in connection
- Max. external inductivity Lo 1 mH
- Vibration A
- ECLASS 9.0 27210129
- Humidity B
- Maximum inrush current 2 A (250 V AC)
- ATEX II (1) G [Ex ia Ga] IIC
- Conformance CE-compliant
- ETIM 6.0 EC002568
- UNSPSC 11 39121008
- ETIM 3.0 EC001446
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?