About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2924692 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 116 mm
- Depth 114.5 mm
- Shock 15g, according to IEC 60068-2-27
- Sensor types that can be used (TC) B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
- Current output signal 4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
- Maximum switching voltage 30 V AC (30 V DC)
- Power consumption < 1.5 W
- Maximum temperature coefficient 0.01 %/K
- Overvoltage category II
- Color gray
- Max. output voltage Uo 6 V
- Max. external capacitance Co 15 µF
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Potentiometer resistance range 0 Ω ... 50 kΩ
- Configurable/programmable Yes
- Load/output load current output ≤ 600 Ω (at 20 mA)
- Mechanical service life 1x 105 cycles
- Stripping length 8 mm
- Conductor cross section AWG 24 ... 16
- Designation EAC Ex
- Rated insulation voltage 300 Vrms
- Group IIC
- Typical deviation from the measuring range final value 2 %
- Noise emission EN 61000-6-4
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Maximum altitude ≤ 2000 m
- Input signal range -1000 mV ... 1000 mV
- Max. current output signal 22 mA
- Contact type 1 changeover contact
- Contact material AgSnO2, hard gold-plated
- Conductor cross section solid 0.2 mm² ... 1.5 mm²
- Status display Green LED (supply voltage, PWR)
- Electrical isolation 4-way, between input/output/power supply/switching output
- Max. output current Io 7.4 mA
- Width 17.5 mm
- Ambient temperature (operation) -20 °C ... 65 °C
- Vibration (operation) 5g, accordance to IEC 60068-2-6
- Temperature measuring range -250 °C ... 2500 °C (Range depending on the sensor type)
- Load/output load voltage output ≥ 10 kΩ
- Output name Switching output
- Supply voltage range 24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
- Typical current consumption < 50 mA (24 V DC)
- Step response (0–99%) typ. 1000 ms (With SIL)
- Electromagnetic compatibility Conformance with EMC directive
- Interference emission EN 61000-6-4
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Permissible humidity (operation) typ. 5 % ... 95 % (non-condensing)
- Sensor types (RTD) that can be used Pt, Ni, Cu sensors: 2, 3, 4-wire
- Voltage input signal -1 V ... 1 V
- Behavior in the event of a sensor error according to NE 43 or freely configurable
- Maximum inrush current 0.5 A (30 V AC)
- Connection method Push-in connection
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Degree of pollution 2
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Housing material PA 6.6-FR
- Max. internal capacitance Ci 44 nF
- Standards/regulations EN 61000-4-6
- UL, USA/Canada UL 508 Listed
- Safety-related maximum voltage Um 253 V AC/DC
- DNV GL-Temperature B
- Identification [Ex ia Ga] IIC
- DNV GL-EMC A
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 5.0 27200200
- ECLASS 9.0 27210129
- ETIM 2.0 EC001446
- ETIM 4.0 EC001446
- UNSPSC 7.0901 39121008
- UNSPSC 11 39121008
- UNSPSC 20.0 41112105
- UNSPSC 19.0 41112105
- UNSPSC 21.0 41112105
- Max. internal inductance Li negligible
- DNV GL-Humidity B
- Temperature B
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27210129
- ECLASS 6.0 27200200
- ETIM 6.0 EC002919
- ETIM 7.0 EC002919
- UNSPSC 18.0 41112105
- Max. output power Po 11 mW
- Max. external inductivity Lo 1 mH
- Conformance CE-compliant
- IECEx [Ex ia Ga] IIC
- Humidity B
- ECLASS 10.0.1 27210129
- ECLASS 4.1 27200200
- ECLASS 4.0 27200200
- ECLASS 5.1 27200200
- ETIM 3.0 EC001446
- UNSPSC 12.01 39121008
- UNSPSC 13.2 41112105
- Degree of protection IP20 (not assessed by UL)
- ATEX II (1) G [Ex ia Ga] IIC
- DNV GL-Vibration A
- Certificate RU C-DE.AB72.B.00093/19
- EMC A
- Vibration A
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 7.0 27200206
- UNSPSC 6.01 30211506
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?