2924689 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2924689
Manufacturer:Phoenix Contact
Category:Electrical Measuring & Monitoring Instruments
Product Lifecycle:Active
Get a quick Quote!
Programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-conductor technology, thermocouples, electrical isolation, wide-range power supply, Push-in connection, SIL
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2924689 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Ambient temperature (operation) -20 °C ... 65 °C
- Degree of protection IP20 (not assessed by UL)
- Sensor types that can be used (TC) B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Voltage input signal -1 V ... 1 V
- Current output signal 4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
- Load/output load current output ≤ 600 Ω (at 20 mA)
- Overvoltage category II
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Temperature B
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27210129
- ECLASS 7.0 27200206
- ETIM 4.0 EC001446
- ETIM 7.0 EC002919
- UNSPSC 21.0 41112105
- UNSPSC 12.01 39121008
- Height 116 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Sensor types (RTD) that can be used Pt, Ni, Cu sensors: 2, 3, 4-wire
- Potentiometer resistance range 0 Ω ... 50 kΩ
- Load/output load voltage output ≥ 10 kΩ
- Contact type 1 changeover contact
- Mechanical service life 1x 105 cycles
- Connection method Push-in connection
- Maximum temperature coefficient 0.01 %/K
- Depth 114.5 mm
- Permissible humidity (operation) typ. 5 % ... 95 % (non-condensing)
- Shock 15g, according to IEC 60068-2-27
- Max. voltage output signal ± 11 V
- Max. current output signal 22 mA
- Behavior in the event of a sensor error according to NE 43 or freely configurable
- Maximum inrush current 0.5 A (30 V AC)
- Power consumption < 1.5 W
- Conductor cross section solid 0.2 mm² ... 1.5 mm²
- Conductor cross section AWG 24 ... 16
- Width 17.5 mm
- Maximum altitude ≤ 2000 m
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Temperature measuring range -250 °C ... 2500 °C (Range depending on the sensor type)
- Contact material AgSnO2, hard gold-plated
- Supply voltage range 24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Electromagnetic compatibility Conformance with EMC directive
- Housing material PA 6.6-FR
- Vibration (operation) 5g, accordance to IEC 60068-2-6
- Input signal range -1000 mV ... 1000 mV
- Configurable/programmable Yes
- Output name Switching output
- Maximum switching voltage 30 V AC (30 V DC)
- Typical current consumption < 50 mA (24 V DC)
- Stripping length 8 mm
- Status display Green LED (supply voltage, PWR)
- Interference emission EN 61000-6-4
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Rated insulation voltage 300 Vrms
- Max. output current Io 7.4 mA
- Max. output power Po 11 mW
- Group IIC
- Typical deviation from the measuring range final value 2 %
- Standards/regulations EN 61000-4-6
- DNV GL-Temperature B
- DNV GL-Vibration A
- Identification [Ex ia Ga] IIC
- Certificate DNV 18.0143 X
- Vibration A
- China RoHS Environmentally Friendly Use Period = 50 years
- Electrical isolation 4-way, between input/output/power supply/switching output
- Max. output voltage Uo 6 V
- Max. external capacitance Co 21 µF
- Conformance CE-compliant
- Step response (0–99%) typ. 1000 ms (With SIL)
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 9.0 27210129
- ETIM 6.0 EC002919
- UNSPSC 11 39121008
- UNSPSC 20.0 41112105
- Designation INMETRO
- Max. internal inductance Li negligible
- Safety-related maximum voltage Um 253 V AC/DC
- UL, USA/Canada UL 508 Listed
- DNV GL-EMC A
- Humidity B
- ECLASS 4.0 27200200
- UNSPSC 13.2 41112105
- Degree of pollution 2
- Color gray
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Additional text mixed circuit
- ATEX II (1) G [Ex ia Ga] IIC
- DNV GL-Humidity B
- EMC A
- ECLASS 4.1 27200200
- ETIM 3.0 EC001446
- UNSPSC 7.0901 39121008
- UNSPSC 19.0 41112105
- Max. internal capacitance Ci 44 nF
- Max. external inductivity Lo 1 mH
- Noise emission EN 61000-6-4
- IECEx [Ex ia Ga] IIC
- ECLASS 5.0 27200200
- ECLASS 6.0 27200200
- ECLASS 10.0.1 27210129
- ECLASS 5.1 27200200
- ETIM 2.0 EC001446
- UNSPSC 6.01 30211506
- UNSPSC 18.0 41112105
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?