2924676 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2924676
Manufacturer:Phoenix Contact
Category:Electrical Measuring & Monitoring Instruments
Product Lifecycle:Active
Get a quick Quote!
Ex i measuring transducer repeater power supply, 2-channel, HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4…20 mA signal from the Ex area to the safe area. 5-way electrical isolation, Push-in connection, up to SIL 3,
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2924676 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (storage/transport) -40 °C ... 80 °C
- Degree of protection IP20 (not assessed by UL)
- Permissible humidity (operation) 10 % ... 95 % (non-condensing)
- Transmission Behavior 1:1 to input signal
- Max. current consumption < 100 mA (24 V / 20 mA)
- Ambient temperature (operation) -20 °C ... 60 °C (Any mounting position)
- Current input signal 4 mA ... 20 mA
- Signal output Current output
- Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Conductor cross section solid 0.2 mm² ... 1.5 mm²
- Stripping length 8 mm
- Maximum temperature coefficient < 0.01 %/K
- Electromagnetic compatibility Conformance with EMC directive
- Housing material PA 6.6-FR
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Max. output voltage Uo 25.2 V
- Max. external capacitance Co 820 nF
- ATEX II (1) G [Ex ia Ga] IIC
- DNV GL-Humidity B
- Temperature B
- EMC A
- ECLASS 10.0.1 27210120
- ECLASS 9.0 27210120
- ETIM 7.0 EC002653
- UNSPSC 11 39121008
- Height 116 mm
- Maximum altitude ≤ 2000 m
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- Output behavior in the event of an error < 3.6 mA (In the event of cable break at the input (as per NE 43))
- Connection method Push-in connection
- Conductor cross section AWG 24 ... 16
- Status display Green LED (supply voltage)
- Interference emission EN 61000-6-4
- Designation INMETRO
- HART function Yes
- Max. output power Po 587 mW
- Safety-related maximum voltage Um 253 V AC (125 V DC)
- Conformance CE-compliant, additionally EN 61326
- DNV GL-Temperature B
- Humidity B
- REACh SVHC Lead 7439-92-1
- ECLASS 5.0 27210100
- ETIM 4.0 EC002653
- UNSPSC 6.01 30211506
- Depth 114.5 mm
- Signal input Intrinsically safe
- Underload/overload signal range 0 mA ... 24 mA
- Nominal supply voltage 24 V DC
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Connection name Test socket
- Step response (10-90%) < 1.3 ms (for 4 mA ... 20 mA step)
- Overvoltage category II
- Rated insulation voltage 300 Vrms
- Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
- Additional text and EN 61326
- IECEx [Ex ia Ga] IIC
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Certificate DNV 18.0140 X
- ECLASS 4.0 27210100
- Width 12.5 mm
- Transmitter supply voltage > 16 V (at 20 mA)
- Current output signal 4 mA ... 20 mA (active)
- Load/output load current output ≤ 450 Ω (20 mA)
- Power dissipation < 1.4 W (at 24 V DC / 20 mA)
- Max. diameter 2.3 mm
- No. of channels 2
- Degree of pollution 2
- Test voltage 1.5 kV AC (50 Hz, 1 min.)
- Group IIC
- Max. external inductivity Lo 100 µH
- Maximum transmission error < 0.1 % (of final value)
- Transmission error, typical < 0.05 % (of final value)
- Color gray
- Protocols supported HART
- Max. output current Io 93 mA
- Standards/regulations GB 3626.20
- UL, USA/Canada Class I Div 2; IS for Class I, II, III Div 1
- DNV GL-EMC A
- Vibration A
- ECLASS 11.0 27210120
- ECLASS 6.0 27210100
- DNV GL-Vibration A
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 7.0 27210120
- UNSPSC 7.0901 39121008
- UNSPSC 21.0 39121008
- Identification [Ex ia Ga] IIC/IIB
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 4.1 27210100
- ETIM 6.0 EC002653
- UNSPSC 19.0 39121008
- UNSPSC 20.0 39121008
- Noise emission EN 61000-6-4
- ECLASS 5.1 27210100
- UNSPSC 12.01 39121008
- UNSPSC 13.2 39121008
- UNSPSC 18.0 39121008
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.