2924061 Phoenix Contact Electrical Measuring & Monitoring Instruments
Part#:2924061
Manufacturer:Phoenix Contact
Category:Electrical Measuring & Monitoring Instruments
Product Lifecycle:Active
Get a quick Quote!
Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2924061 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 116 mm
- Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
- Switching points (attenuated) < 1.2 mA (blocking)
- Short-circuit current ~ 8 mA
- Contact type 2 N/O contacts
- Maximum switching voltage 250 V AC (2 A)
- Nominal supply voltage 24 V DC
- Stripping length 8 mm
- Color gray
- Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
- Integrity requirement IEC 61508 - Low demand
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of protection IP20 (not assessed by UL)
- Switching points (unattenuated) > 2.1 mA (conductive)
- Maximum switching capacity 500 VA
- Max. current consumption 30 mA (24 V DC)
- Width 12.5 mm
- Maximum altitude ≤ 2000 m
- Switching hysteresis < 0.2 mA
- Mechanical service life 107 cycles
- Power consumption < 950 mW
- No. of channels 1
- Conductor cross section solid 0.2 mm² ... 1.5 mm²
- Rated insulation voltage 300 Vrms
- Equipment type Type A
- Probability of a hazardous failure on demand (PFDAVG) 3.01 x 10-4 (1 year)
- Max. output power Po 25 mW
- Standards/regulations GB 3626.20
- UL, USA/Canada Class I Div 2; IS for Class I, II, III Div 1
- DNV GL-EMC B
- Vibration A
- Depth 114.5 mm
- Permissible humidity (operation) 10 % ... 95 % (non-condensing)
- Non-load voltage ~ 8 V DC
- Line fault detection Break 0.05 mA < IIN < 0.35 mA
- Contact material AgSnO2, hard gold-plated
- Switching frequency ≤ 20 Hz (without load)
- Power dissipation < 950 mW
- Conductor cross section AWG 24 ... 16
- Overvoltage category III
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- λSU 2.48 x 10-7 (248 FIT)
- Max. internal capacitance Ci 11 nF
- Diagnostic coverage (DC) DCS = 0.4 %, DCD = 8 %
- Conformance CE-compliant, additionally EN 61326
- Humidity B
- Ambient temperature (operation) -20 °C ... 60 °C (Any mounting position)
- Noise immunity EN 61000-6-2 EN 61326
- Available input sources NAMUR proximity sensors (EN 60947-5-6)
- Signal input Intrinsically safe
- Switching output Relay output
- Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Designation EAC Ex
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Housing material PA 6.6-FR
- Degree of pollution 2
- λDU 6.2 x 10-8 (62 FIT)
- λDD 6 x 10-9 (6 FIT)
- Max. output voltage Uo 9.6 V
- Group IIC
- Additional text and EN 61326
- DNV GL-Temperature B
- DNV GL-Humidity B
- REACh SVHC Lead 7439-92-1
- ECLASS 10.0.1 27210121
- ECLASS 4.0 27210100
- ECLASS 9.0 27210121
- ETIM 6.0 EC001485
- UNSPSC 19.0 39121008
- Max. external capacitance Co 1 µF
- IECEx [Ex ia Ga] IIC
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- Temperature B
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 4.1 27210100
- ECLASS 7.0 27210121
- UNSPSC 6.01 30211506
- UNSPSC 20.0 39121008
- Safe Failure Fraction (SFF) 78 %
- Max. internal inductance Li negligible
- Max. output current Io 10 mA
- DNV GL-Vibration A
- Certificate RU C-DE.AB72.B.00093/19
- China RoHS Environmentally Friendly Use Period = 50 years
- ETIM 2.0 EC001485
- UNSPSC 7.0901 39121008
- UNSPSC 11 39121008
- Test voltage 2.5 kV AC (50 Hz, 1 min.)
- Safety Integrity Level (SIL) 2
- λSD 1 x 10-9 (1 FIT)
- Safety-related maximum voltage Um 253 V AC (125 V DC)
- ECLASS 5.1 27210100
- ECLASS 6.0 27210100
- ETIM 7.0 EC001485
- Connection method Push-in connection
- ECLASS 11.0 27210121
- ECLASS 5.0 27210100
- UNSPSC 18.0 39121008
- Status display Green LED (supply voltage)
- ATEX II (1) G [Ex ia Ga] IIC
- ETIM 3.0 EC001485
- ETIM 4.0 EC001485
- UNSPSC 13.2 39121008
- Max. external inductivity Lo 10 µH
- Identification [Ex ia Ga] IIC
- EMC B
- UNSPSC 12.01 39121008
- UNSPSC 21.0 39121008
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.