2920104 Phoenix Contact Electrical Measuring & Monitoring Instruments

2920104 on Power Resource International
Phoenix Contact

Part#:2920104

Manufacturer:Phoenix Contact

Category:Electrical Measuring & Monitoring Instruments

Product Lifecycle:Active

Get a quick Quote!

Surge protection plug with integrated diagnostic and status indicator on the module and remote indication contact for two signal wires with common reference potential. Nominal voltage: 5 V DC

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2920104 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Width
    17.5 mm
  • Complete module height
    90 mm
  • Housing material
    PA 6.6
  • Standards for cearances and creepage distances
    VDE 0110-1
  • VDE requirement class
    C1
  • Nominal discharge current In (8/20) µs (line-earth)
    10 kA
  • Output voltage limitation at 1 kV/µs (line-signalground) spike
    ≤ 14 V
  • Response time tA (line-earth)
    ≤ 1 ns
  • Cut-off frequency fg (3 dB), asym. (signal ground) in 150 Ω system
    typ. 0.4 MHz
  • Impulse durability (line-earth)
    C2 - 10 kV / 5 kA
  • Stripping length
    8 mm
  • Depth
    51.7 mm
  • Degree of protection
    IP20
  • Type
    Male
  • Nominal voltage UN
    5 V DC
  • Residual current IPE
    ≤ 1 µA (with PT 2X1+F-BE)
  • Output voltage limitation at 1 kV/µs (line-earth) static
    ≤ 11 V
  • Voltage protection level Up (line-earth)
    ≤ 11 V (C1 - 500 V / 250 A)
  • Resistance per path
    4.7 Ω (7-8/11-12)
  • Screw thread
    M3
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 5.0
    27130800
  • Height
    44.8 mm
  • Complete module depth
    65.5 mm
  • Mounting type
    on base element
  • Maximum continuous voltage UC
    6 V DC
  • Pulse discharge current Iimp (10/350) µs
    2.5 kA (per path)
  • Max. discharge current Imax (8/20) µs maximum (line-earth)
    10 kA
  • Output voltage limitation at 1 kV/µs (line-signalground) static
    ≤ 11 V
  • Residual voltage with Ian (10/1000) µs (line-earth)
    ≤ 12 V
  • Input attenuation aE, asym.
    typ. 0.5 dB (≤ 200 kHz / 50 Ω)
  • Alternating current carrying capacity (line-earth)
    5 A - 1 s
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • Switching function
    N/C contact
  • Max. operating current Imax
    0.2 A (250 V AC)
  • ECLASS 11.0
    27130807
  • ECLASS 4.1
    27130800
  • ECLASS 9.0
    27130807
  • ETIM 3.0
    EC000943
  • UNSPSC 20.0
    39121620
  • Horizontal pitch
    1 Div.
  • Ambient temperature (operation)
    -40 °C ... 85 °C
  • Color
    black
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • Operating effective current IC at UC
    ≤ 1 mA
  • Total discharge current Itotal (8/20) µs
    20 kA
  • Output voltage limitation at 1 kV/µs (line-earth) spike
    ≤ 14 V
  • Residual voltage at In (line-earth)
    ≤ 10 V
  • Max. required back-up fuse
    315 mA (T)
  • Tightening torque
    0.8 Nm
  • Standards/regulations
    IEC 61643-21
  • ECLASS 10.0.1
    27130807
  • ECLASS 6.0
    27130800
  • ETIM 4.0
    EC000943
  • UNSPSC 6.01
    30212010
  • UNSPSC 13.2
    39121620
  • Utilization restriction
    EMC: class A product, see manufacturer's declaration in the download area
  • Complete module width
    17.7 mm
  • Flammability rating according to UL 94
    V-0
  • IEC test classification
    C1
  • Rated current
    300 mA (45 °C)
  • Nominal pulse current Ian (10/1000) µs (line-earth)
    145 A (25 °C / 1x)
  • Voltage protection level Up (line-signalground)
    ≤ 11 V (C1 - 500 V / 250 A)
  • Cut-off frequency fg (3 dB), asym. (signal ground) in 50 Ω system
    typ. 1 MHz
  • Surge protection fault message
    Optical, remote indicator contact
  • Connection method
    Screw connection (in connection with the base element)
  • Maximum operating voltage Umax. AC
    250 V AC
  • Standards/specifications
    IEC 61643-21 2002
  • ECLASS 4.0
    27130800
  • ECLASS 5.1
    27130800
  • ETIM 6.0
    EC000943
  • UNSPSC 12.01
    39121610
  • Conductor cross section AWG
    24 ... 12
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 7.0
    27130807
  • ETIM 7.0
    EC000943
  • UNSPSC 7.0901
    39121610
  • UNSPSC 19.0
    39121620
  • ETIM 2.0
    EC000943
  • UNSPSC 11
    39121610
  • UNSPSC 18.0
    39121620
  • UNSPSC 21.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?