Primary-switched DC/DC converter, QUINT POWER, DIN rail mounting, SFB Technology (Selective Fuse Breaking), Push-in connection, input: 24 V DC , output: 24 V DC / 10 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers DC/DC Converters that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2910120 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight 0.8 kg
- ECLASS 10.0.1 27210901
- Electric strength, max. 35 V DC (60 s)
- Inrush current limitation typical 1.5 A (after 1 ms)
- Type test (IEC/EN 60950-1) D 0.5 kV DC
- Production test D 0.5 kV DC
- Static Boost (IStat.Boost) 12.5 A
- Conductor cross section AWG 24 ... 16
- Typical current consumption 13.8 A (24 V DC)
- Type test (IEC/EN 60950-1) B 4 kV DC
- Stripping length 8 mm
- System deviation, input voltage change < 0.1 % (change in input voltage ±10 %)
- Feedback voltage resistance ≤ 35 V DC
- UOut > 0.9 x USet (LED lights up green)
- Default Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
- Switch contact floating
- Main converter stage 67 kHz ... 135 kHz (Main converter stage)
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Width with alternative assembly 122 mm
- Depth with alternative assembly 53 mm
- Vibration (operation) 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
- Overvoltage category EN 61010-1 II
- EMC requirements for noise immunity EN 61000-6-1
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electrostatic discharge EN 61000-4-2
- Frequency range 50 Hz ... 60 Hz
- Comments Criterion A
- Input 1 kV (Test Level 3 - symmetrical)
- I/O/S asymmetrical
- Voltage dips EN 61000-4-29
- Test level 2 150 Hz 1.5 kHz (Test Level 3)
- Attenuated oscillating wave EN 61000-4-18
- Criterion A Normal operating behavior within the specified limits.
- Input voltage range 18 V DC ... 32 V DC
- Typical response time 300 ms (from SLEEP MODE)
- Insulation voltage input/output 4 kV DC (type test)
- Type test (IEC/EN 60950-1) C 0.5 kV DC
- Production test B 2 kV DC
- Conductor cross section solid 0.2 mm² ... 1 mm²
- Flexible conductor cross section flexible (ferrule, w/o plastic sleeve) 0.2 mm² ... 1.5 mm²
- Setting range of the output voltage (USet) 24 V DC ... 29.5 V DC (> 24 V DC, constant capacity)
- Selective Fuse Breaking (ISFB) 60 A (15 ms)
- Residual ripple < 50 mVPP
- Protection against overvoltage at the output (OVP) ≤ 32 V DC
- Connection labeling 3.4 +
- Reference potential to OUT1, OUT2, REM
- MTBF (IEC 61709, SN 29500) > 1380000 h (25 °C)
- Hood version Stainless steel X6Cr17
- Depth 125 mm
- Ambient temperature (start-up type tested) -40 °C
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Degree of pollution 2
- EMC requirements for noise emission EN 61000-6-3
- Overvoltage category EN 62477-1 III
- Identification ABS
- Conducted noise emission EN 55016
- Switch-on time < 1 s
- Type test (IEC/EN 60950-1) A 2 kV DC
- Production test A 2 kV DC
- Flexible conductor cross section (ferrule with plastic sleeve) 0.2 mm² ... 0.75 mm²
- Nominal output voltage (UN) 24 V DC
- Dynamic Boost (IDyn.Boost) 20 A (5 s)
- System deviation, static < 1 % (change in load, static 10 % ... 90 %)
- No-load proof yes
- Rise time < 1 s (UOUT (10 % ... 90 %))
- POut > 100 % (LED lights up yellow, output power > 240 W)
- Signal option Output current
- Maximum contact load 24 V DC
- Temperature 30 °C
- Side element version Aluminum
- Protection class Special with SELV input and output
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- EMC requirements, power plant IEC 61850-3
- Designation Shipbuilding
- Noise emission EN 55016
- DNV GL noise radiation Class B
- Discharge in air 15 kV (Test Level 4)
- Electromagnetic HF field EN 61000-4-3
- Surge voltage load (surge) EN 61000-4-5
- Frequency 0 Hz
- Voltage dip 0 %
- Test level 4 15 kHz 150 kHz (Test Level 3)
- Alternating component of DC voltage EN 61000-4-17
- Input, output (test level 1) 100 kHz 1 MHz (Test Level 2 - symmetrical)
- Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
- ECLASS 9.0 27210901
- Mains buffering typ. 11 ms (24 V DC)
- Inrush current integral (I2t) < 0.02 A2s
- Input fuse 30 A (slow-blow, internal)
- Production test C 0.5 kV DC
- Connection method Push-in connection
- Conductor cross section flexible 0.2 mm² ... 1.5 mm²
- Nominal output current (IN) 10 A
- Magnetic circuit breaker tripping A1...A6 / B2...B6 / C1...C3 / Z1...Z6
- Short-circuit-proof yes
- Connection in series yes
- Types of signaling LED
- Analog 4 mA ... 20 mA ±5 % (Load ≤400 Ω)
- Output current 10 A
- Voltage 1 kV
- Auxiliary converter stage 190 kHz ... 220 kHz (Auxiliary converter stage)
- Height 130 mm
- Efficiency typ. 93.3 % (24 V DC)
- Maximum power dissipation in no-load condition < 5 W
- Power dissipation SLEEP MODE < 2 W
- Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
- Climatic class 3K3 (EN 60721)
- Standard designation Mains variation/undervoltage
- Standards/regulations EN 61000-4-29
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- DNV GL conducted interference Class B
- Additional text Test Level 2
- Fast transients (burst) EN 61000-4-4
- Output 1 kV (Test Level 3 - symmetrical)
- Conducted interference EN 61000-4-6
- Damped oscillating magnetic field EN 61000-4-10
- Asymmetrical conducted disturbance variables EN 61000-4-16
- Test level 5 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
- Signals (test level 1) 100 kHz 1 MHz (Test Level 2 - symmetrical)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ETIM 7.0 EC002046
- System deviation, dynamic < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
- Connection in parallel Yes, for redundancy and increased capacity
- UIn > 0.8 x UInNom (LED off)
- Digital 0 V DC
- Function Signal ground
- Time 422400 h
- Degree of protection IP20
- Width 50 mm
- Height with alternative assembly 130 mm
- Power loss nominal load max. < 16 W
- Maximum altitude ≤ 5000 mm (> 2000 m, observe derating)
- Test level 1 15 Hz 150 Hz (Test Level 3)
- Test level 6 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
- Input, output (test level 3) 10 MHz (Test Level 2 - asymmetrical)
- ECLASS 11.0 27210901
- Contact discharge 8 kV (Test Level 4)
- Test field strength 100 A/m
- Signal 2 kV (Test Level 3 - asymmetrical)
- Power frequency magnetic field EN 61000-4-8
- Pulse-shape magnetic field EN 61000-4-9
- Test level 3 1.5 kHz 15 kHz (Test Level 3)
- Input, output (test level 2) 100 kHz 1 MHz (Test Level 2 - asymmetrical)
- Signals (test level 2) 100 kHz 1 MHz (Test Level 2 - asymmetrical)
- ETIM 6.0 EC002046
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?