Ex i measuring transducer supply conditioner and input signal conditioner, only output 1 is HART-transparent. Transmits supplied or active signals from the Ex area with electrical isolation to two loads. SIL 2 in accordance with IEC 61508, screw connectio
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2908855 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height 112.5 mm
- Permissible humidity (operation) 10 % ... 95 % (non-condensing)
- Underload/overload signal range 0 mA ... 24 mA (Extended transmission range for diagnostics)
- Output ripple < 20 mVrms
- Designation INMETRO
- Vibration A
- ECLASS 10.0.1 27210120
- ECLASS 5.0 27210100
- Signal output Signal conditioner operation
- Nominal supply voltage 24 V DC
- Temperature B
- China RoHS Environmentally Friendly Use Period = 50 years
- ECLASS 5.1 27210100
- Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
- DNV GL-Vibration A
- Certificate DNV 18.0139 X
- REACh SVHC Lead 7439-92-1
- ECLASS 4.1 27210100
- ECLASS 7.0 27210120
- ETIM 7.0 EC002653
- DNV GL-EMC A
- Humidity B
- Enclosure Required protection according to the Rules shall be provided upon installation on board
- Noise emission EN 61000-6-4
- Nominal supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Connection name Test socket
- Maximum transmission error < 0.1 % (of final value)
- Rated insulation voltage 300 Vrms
- Overvoltage category II
- Protocols supported HART
- Group IIC
- Input voltage Ui ≤ 30 V
- DNV GL-Temperature B
- Utilization restriction EMC: class A product, see manufacturer's declaration in the download area
- Depth 114.5 mm
- Current input signal 0 A ... 20 mA
- Transmitter supply voltage > 16 V (20 mA)
- Output behavior in the event of an error 0 mA (Cable break in the input)
- Connection method Screw connection
- No. of channels 1
- Maximum temperature coefficient < 0.01 %/K
- Max. output power Po 587 mW
- Max. external inductivity Lo 10 µH
- Max. internal inductance Li negligible
- ATEX II (1) G [Ex ia Ga] IIC
- Identification [Ex ia Ga] IIC
- ECLASS 4.0 27210100
- ETIM 4.0 EC002653
- ETIM 6.0 EC002653
- Width 12.5 mm
- Maximum altitude ≤ 2000 m
- Load/output load current output < 450 Ω (20 mA)
- Supply voltage range 19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
- Screw thread M3
- Electromagnetic compatibility Conformance with EMC directive
- Insulation Safe isolation in accordance with IEC/EN 61010-1
- Max. external capacitance Co 1 µF
- Safety-related maximum voltage Um 253 V AC (125 V DC)
- Max. internal capacitance Ci negligible
- DNV GL-Humidity B
- ECLASS 11.0 27210120
- Ambient temperature (operation) -20 °C ... 60 °C (Any mounting position)
- Signal input Signal conditioner operation
- Power dissipation < 1.1 W (24 V DC / 20 mA)
- Conductor cross section flexible 0.2 mm² ... 2.5 mm²
- Max. diameter 2 mm
- Housing material PA 6.6-FR
- Test voltage 1.5 kV AC (50 Hz, 1 min.)
- HART function Yes
- Standards/regulations GB 3626.20
- IECEx [Ex ia Ga] IIC
- Voltage drop approx. 3.9 V (in input isolating amplifier operation)
- Current output signal 0 mA ... 20 mA (active)
- Max. current consumption < 46 mA (24 V DC / 20 mA)
- Stripping length 7 mm
- Torque 0.5 Nm ... 0.6 Nm
- Transmission error, typical < 0.05 % (of final value)
- Interference emission EN 61000-6-4
- Color gray
- Electrical isolation 375 V (Peak value in accordance with IEC/EN 60079-11)
- Max. output current Io 93 mA
- Additional text and EN 61326
- Input current Ii ≤ 150 mA
- UL, USA/Canada Class I Div 2; IS for Class I, II, III Div 1
- DNV GL-Enclosure Required protection according to the Rules shall be provided upon installation on board
- ECLASS 9.0 27210120
- Ambient temperature (storage/transport) -40 °C ... 80 °C
- Degree of protection IP20 (not assessed by UL)
- Polarization and surge protection Yes
- Conductor cross section solid 0.2 mm² ... 2.5 mm²
- Conductor cross section AWG 24 ... 14
- Step response (10-90%) 1.3 ms (Output 1, for jump 4 mA ... 20 mA, typical)
- Status display Green LED (PWR supply voltage)
- Degree of pollution 2
- Operation Signal conditioner operation
- Max. output voltage Uo 25.2 V
- Conformance CE-compliant, additionally EN 61326
- EMC A
- ECLASS 6.0 27210100
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?