2908198 Phoenix Contact Electrical Measuring & Monitoring Instruments

2908198 on Power Resource International
Phoenix Contact

Part#:2908198

Manufacturer:Phoenix Contact

Category:Electrical Measuring & Monitoring Instruments

Product Lifecycle:Active

Get a quick Quote!

Surge protection, consisting of protective plug and base element, with integrated status indicator for a 2-wire floating signal circuit. Indirect grounding via gas-filled surge arrester.

About the manufacturer: Phoenix Contact is one of the manufacturers that offers Electrical Measuring & Monitoring Instruments that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.

Check out the 2908198 Phoenix Contact price in the box on the right side or send a quick quote.

Product Details

  • Depth
    100 mm (incl. DIN rail 7.5 mm)
  • Color
    traffic grey A RAL 7042
  • Maximum continuous voltage UC
    15 V DC
  • Nominal discharge current In (8/20) µs (line-signal ground)
    5 kA
  • Voltage protection level Up static (line-earth)
    ≤ 900 V (C1 - 1 kV/500 A)
  • Resistance per path
    1.65 Ω ±20 %
  • Impulse durability (line-earth)
    C1 - 1 kV / 500 A
  • Pulse reset time (line-signalground)
    ≤ 1500 ms
  • Standards/specifications
    IEC 61643-21 2000 + corrigendum 2001 + A1:2008, modified + A2:2012
  • ECLASS 4.0
    27140201
  • ECLASS 6.0
    27130800
  • ETIM 7.0
    EC000943
  • UNSPSC 13.2
    39121620
  • UNSPSC 19.0
    39121620
  • Height
    105.8 mm
  • Housing material
    PBT
  • Nominal voltage UN
    12 V DC
  • Pulse discharge current Iimp (10/350) µs (line-earth)
    0.5 kA
  • Voltage protection level Up (line-line)
    ≤ 220 V (C1 - 1 kV/500 A)
  • Voltage protection level Up static (line-line)
    ≤ 30 V (C1 - 1 kV/500 A)
  • Input attenuation aE, sym.
    typ. 0.3 dB (≤ 130 kHz/150 Ω)
  • Capacity (line-line)
    typ. 5.2 nF
  • Max. total discharge current I total max (8/20) µs
    20 kA (1x)
  • Conductor cross section solid
    0.2 mm² ... 4 mm²
  • REACh SVHC
    Lead 7439-92-1
  • ECLASS 4.1
    27130801
  • ETIM 6.0
    EC000943
  • ETIM 4.0
    EC000943
  • UNSPSC 21.0
    39121620
  • Ambient temperature (operation)
    -40 °C ... 85 °C
  • Altitude
    ≤ 4000 m (amsl (above mean sea level))
  • Mounting type
    DIN rail: TH 35 - 7.5 mm
  • IEC test classification
    C1
  • Rated current
    600 mA (56 °C)
  • Nominal discharge current In (8/20) µs (line-earth)
    5 kA
  • Total discharge current Itotal (8/20) µs
    10 kA
  • Voltage protection level Up (line-signalground)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Response time tA (line-line)
    ≤ 1 ns
  • Response time tA (line-earth)
    ≤ 100 ns
  • Max. required back-up fuse
    630 mA (FF)
  • Pulse reset time (line-line)
    ≤ 700 ms
  • Connection method
    Push-in connection
  • Conductor cross section AWG
    24 ... 12
  • ECLASS 11.0
    27130807
  • ECLASS 7.0
    27130807
  • UNSPSC 7.0901
    39121610
  • UNSPSC 11
    39121610
  • UNSPSC 12.01
    39121610
  • Ambient temperature (storage/transport)
    -40 °C ... 85 °C
  • Degree of protection
    IP20
  • Type
    DIN rail module, two-section, divisible
  • Operating effective current IC at UC
    ≤ 100 µA
  • Pulse discharge current Iimp (10/350) µs (line-line)
    0.5 kA
  • Pulse discharge current Iimp (10/350) µs (line-signalground)
    0.5 kA
  • Cut-off frequency fg (3 dB), sym. in 150 Ω system
    typ. 420 kHz
  • Impulse durability (line-line)
    C1 - 1 kV / 500 A
  • Pulse reset time (line-earth)
    ≤ 30 ms
  • China RoHS
    Environmentally Friendly Use Period = 50 years
  • ECLASS 5.0
    27130801
  • ECLASS 5.1
    27130801
  • UNSPSC 6.01
    30212010
  • UNSPSC 20.0
    39121620
  • Width
    6.2 mm +0.1 mm
  • Permissible humidity (operation)
    5 % ... 95 %
  • Flammability rating according to UL 94
    V-0
  • Direction of action
    Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
  • Residual current IPE
    ≤ 1 µA
  • Nominal discharge current In (8/20) µs (line-line)
    5 kA
  • Voltage protection level Up (line-earth)
    ≤ 900 V (C1 - 1 kV/500 A)
  • Voltage protection level Up static (line-signalground)
    ≤ 750 V (C1 - 1 kV/500 A)
  • Response time tA (line-signalground)
    ≤ 100 ns
  • Impulse durability (line-signalground)
    C1 - 1 kV / 500 A
  • Stripping length
    8 mm
  • Conductor cross section flexible
    0.2 mm² ... 2.5 mm²
  • ECLASS 10.0.1
    27130807
  • ECLASS 9.0
    27130807
  • ETIM 3.0
    EC000943
  • UNSPSC 18.0
    39121620

Product condition

New Factory Sealed

New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.


Manufacturer warranty

Get a quick Quote!

Request a quote, and we will send you price and availability within minutes.

Select Qty:

Average response time: 11 minutes

Fast Shipping & Delivery


Secure Payment Processing


Warranty


Responsive Customer Support


Need more details?

Feel free to chat with us

What can I help you find today?