2907753 Phoenix Contact Redundancy Modules
Part#:2907753
Manufacturer:Phoenix Contact
Category:Redundancy Modules
Product Lifecycle:Active
Get a quick Quote!
Active QUINT single redundancy module for DIN rail mounting, protective coating, input: 12 - 24 V DC, output: 12 - 24 V DC/1 x 40 A, incl. mounted UTA 107/30 universal DIN rail adapter
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Redundancy Modules that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2907753 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Width 32 mm
- Height with alternative assembly 130 mm
- Frequency range 0.15 MHz ... 80 MHz
- Fast transients (burst) ENÂ 61000-4-4
- Surge voltage load (surge) ENÂ 61000-4-5
- Power frequency magnetic field EN 61000-4-8
- ECLASS 7.0 27371010
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 6.0 27371000
- UNSPSC 13.2 39121004
- Depth 125 mm
- Installation distance right/left 0 mm / 0 mm
- Max. permissible relative humidity (operation) ≤ 100 % (at 25 °C, non-condensing)
- Nominal input voltage range 12 VÂ DC ... 24 VÂ DC
- Screw thread M4
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Shipbuilding approval DNV GL
- Additional text 60 s
- Contact discharge 8 kV (Test Level 4)
- Frequency 16.67 Hz
- ECLASS 10.0.1 27371010
- UNSPSC 19.0 32151504
- UNSPSC 20.0 32151504
- Height 130 mm
- Depth with alternative assembly 35 mm
- Ambient temperature (operation) -40 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Input voltage range 8 VÂ DC ... 26 VÂ DC
- Standard - Electrical safety ENÂ 60950-1/VDEÂ 0805 (SELV)
- Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- DNVÂ GL noise radiation Class B
- Test field strength 30 A/m
- Output 1 kV (Test Level 2 - symmetrical)
- I/O/S asymmetrical
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 5.0 27371000
- ETIM 6.0 EC000599
- Width with alternative assembly 122 mm
- Degree of protection IP20
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- Current consumption 40 A
- Static Boost (IStat.Boost) 45 A
- Connection in series No
- Power loss nominal load max. 6.5 W (IOUT = 40 A)
- Efficiency typ. 99 % (12Â VÂ DC)
- Housing material Aluminum / stainless steel
- Connection method Push-in connection
- Conductor cross section flexible max. 1.5 mm²
- Conductor cross section AWG max. 16
- EMC requirements for noise immunity ENÂ 61000-6-1
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- UL approvals UL/C-UL listed UL 508
- DNVÂ GL conducted interference Class A
- Electrostatic discharge EN 61000-4-2
- Electromagnetic HF field ENÂ 61000-4-3
- Input 1 kV (Test Level 4 - symmetrical)
- Conducted interference ENÂ 61000-4-6
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 11.0 27371010
- ECLASS 9.0 27371010
- UNSPSC 18.0 32151504
- Installation distance top/bottom 40 mm / 20 mm
- Climatic class 3K3 (in acc. with EN 60721)
- Output voltage range 8 VÂ DC ... 26 VÂ DC
- Nominal output current (IN) 40 A
- Selective Fuse Breaking (ISFB) 215 A (15 ms)
- Protection against overvoltage at the output (OVP) ≤ 28.8 V DC
- MTBF (IEC 61709, SN 29500) > 13486000 h (25 °C)
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section flexible min. 0.2 mm²
- Stripping length 8 mm
- EMC requirements for noise emission ENÂ 61000-6-3
- Standard - Safe isolation DINÂ VDEÂ 0100-410
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Conducted noise emission EN 55016
- Discharge in air 15 kV (Test Level 4)
- Comments Criterion A
- Signal 1 kV (Test Level 2 - asymmetrical)
- Voltage 10 V (Test Level 3)
- REACh SVHC Lead 7439-92-1
- ECLASS 5.1 27371000
- ETIM 7.0 EC000599
- UNSPSC 21.0 32151504
- Derating 60 °C ... 70 °C (2.5%/K)
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Conductor cross section solid max. 1.5 mm²
- Noise emission EN 55016
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Nominal input current 40 A (-40 °C ... 60 °C)
- Dynamic Boost (IDyn.Boost) 60 A (5 s)
- Net weight 0.4 kg
- Protection class III
- Conductor cross section AWG min. 24
- Degree of pollution 2
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?