2907752 Phoenix Contact Redundancy Modules
Part#:2907752
Manufacturer:Phoenix Contact
Category:Redundancy Modules
Product Lifecycle:Active
Get a quick Quote!
Active QUINT single redundancy module for DIN rail mounting, input: 12 - 24 V DC, output: 12 - 24 V DC/1 x 40 A, incl. mounted UTA 107/30 universal DIN rail adapter
About the manufacturer: Phoenix Contact is one of the manufacturers that offers Redundancy Modules that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2907752 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Height with alternative assembly 130 mm
- Depth with alternative assembly 35 mm
- Degree of pollution 2
- Current consumption 40 A
- Static Boost (IStat.Boost) 45 A
- Selective Fuse Breaking (ISFB) 215 A (15 ms)
- Connection in series No
- Conductor cross section solid max. 1.5 mm²
- EMC requirements for noise immunity ENÂ 61000-6-1
- Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment EN 50178
- Additional text 60 s
- Test field strength 30 A/m
- Surge voltage load (surge) ENÂ 61000-4-5
- REACh SVHC Lead 7439-92-1
- UNSPSC 13.2 39121004
- Depth 125 mm
- Installation distance top/bottom 40 mm / 20 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Ambient temperature (operation) -40 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Installation height ≤ 5000 m (> 2000 m, observe derating)
- Dynamic Boost (IDyn.Boost) 60 A (5 s)
- Efficiency typ. 99.1 % (12Â VÂ DC)
- Conductor cross section solid min. 0.2 mm²
- Stripping length 8 mm
- EMC requirements for noise emission ENÂ 61000-6-3
- Width with alternative assembly 122 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Input voltage range 8 VÂ DC ... 30 VÂ DC
- Nominal output current (IN) 40 A
- Net weight 0.55 kg
- Mounting position horizontal DIN rail NS 35, EN 60715
- Connection method Push-in connection
- Conductor cross section AWG min. 24
- Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Noise emission EN 55016
- Electrostatic discharge EN 61000-4-2
- Comments Criterion A
- Fast transients (burst) ENÂ 61000-4-4
- Power frequency magnetic field EN 61000-4-8
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 9.0 27371010
- Height 130 mm
- Degree of protection IP20
- Climatic class 3K3 (in acc. with EN 60721)
- Nominal input current 40 A (-40 °C ... 60 °C)
- Derating 60 °C ... 70 °C (2.5%/K)
- MTBF (IEC 61709, SN 29500) > 25297000 h (25 °C)
- Protection class III
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section AWG max. 16
- Screw thread M4
- Standard – Safety extra-low voltage IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Shipbuilding approval DNV GL
- Conducted noise emission EN 55016
- DNVÂ GL noise radiation Class B
- Contact discharge 8 kV (Test Level 4)
- Discharge in air 15 kV (Test Level 4)
- Output 1 kV (Test Level 2 - symmetrical)
- I/O/S asymmetrical
- Conducted interference ENÂ 61000-4-6
- China RoHS Environmentally Friendly Use Period = 25;
- ECLASS 10.0.1 27371010
- ETIM 6.0 EC002540
- Width 32 mm
- Installation distance right/left 0 mm / 0 mm
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Nominal input voltage range 12 VÂ DC ... 24 VÂ DC
- Output voltage range 8 VÂ DC ... 30 VÂ DC
- Power loss nominal load max. 6.5 W (IOUT = 40 A)
- Housing material Aluminum / stainless steel
- Assembly instructions alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm verticallyalignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
- Conductor cross section flexible max. 1.5 mm²
- Standard - Electrical safety ENÂ 60950-1/VDEÂ 0805 (SELV)
- Standard - Safe isolation DINÂ VDEÂ 0100-410
- UL approvals UL/C-UL listed UL 508
- DNVÂ GL conducted interference Class A
- Frequency range 0.15 MHz ... 80 MHz
- Input 1 kV (Test Level 4 - symmetrical)
- Voltage 10 V (Test Level 3)
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 11.0 27371010
- UNSPSC 19.0 39121004
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electromagnetic HF field ENÂ 61000-4-3
- Signal 1 kV (Test Level 2 - asymmetrical)
- Frequency 16.67 Hz
- ECLASS 5.1 27242213
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?