2907161 Phoenix Contact UPS (DC)
Part#:2907161
Manufacturer:Phoenix Contact
Category:UPS (DC)
Product Lifecycle:Active
Get a quick Quote!
Uninterruptible power supply with integrated power supply unit. For lead AGM energy storage with 1.3 Ah to 38 Ah nominal capacity. Input: 1-phase, output: 24 V DC/10 A. Push-in connection technology
About the manufacturer: Phoenix Contact is one of the manufacturers that offers UPS (DC) that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2907161 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Depth with alternative assembly 68 mm
- Degree of protection IP20
- Max. permissible relative humidity (operation) ≤ 93 % (At +25°C, non-condensing)
- Climatic class 3K3 (in acc. with EN 60721)
- Mains buffering time ≥ 25 ms (120 V AC)
- Derating > 60 °C (2.5%/K of POut nom.)
- Width 68 mm
- Installation distance right/left 0 mm / 0 mm
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- AC input voltage range 100 V AC ... 240 V AC -15 % ... +10 %
- Nominal output voltage 24 VÂ DC
- Setting range of the output voltage (USet) 24 VÂ DC ... 28 VÂ DC (> 24Â V constant capacity)
- Feedback voltage resistance ≤ 35 V DC
- Connection method Push-in connection
- Conductor cross section AWG max. 16
- Standard – Safety extra-low voltage IEC 61010 (SELV) / (PELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Discharge in air 8 kV (Test Level 4)
- Test field strength 10 V/m (Test Level 3)
- Conducted interference ENÂ 61000-4-6
- Attenuated sinusoidal oscillations (ring wave) EN 61000-4-12
- ECLASS 9.0 27040705
- Height 130 mm
- Height with alternative assembly 130 mm
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Typical response time 200 ms
- Dynamic Boost (IDyn.Boost) 15 A
- Maximum power dissipation in no-load condition < 3 W (230 V AC)
- Residual ripple < 20 mV
- MTBF (IEC 61709, SN 29500) > 2007013 h (230 V AC, at 25 °C)
- Protection class I
- Conductor cross section solid min. 0.2 mm²
- Stripping length 8 mm
- EMC requirements for noise immunity ENÂ 61000-6-1
- Standard - power supply devices for low voltage with DC output ENÂ 61204-3
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- DNVÂ GL noise radiation Class B
- Contact discharge 6 kV (Test Level 4)
- Fast transients (burst) ENÂ 61000-4-4
- Surge voltage load (surge) ENÂ 61000-4-5
- ECLASS 11.0 27040705
- Width with alternative assembly 160 mm
- Degree of pollution 2
- Inrush current limiting/I²t < 0.2 A2s
- Input fuse, integrated 6.3 A (slow-blow, internal)
- Efficiency typ. 90 % (120Â VÂ AC)
- Surge protection against internal surge voltages < 30 VÂ DC
- Assembly instructions alignable: horizontally 0Â mm, vertically 50Â mm
- Conductor cross section flexible max. 1.5 mm²
- Conductor cross section AWG min. 24
- Charge current 0.2 A ... 3 A (-25 °C ... 60 °C)
- Conducted noise emission ENÂ 61000-6-3 (Class B)
- Additional text Bridge and deck area
- Electromagnetic HF field ENÂ 61000-4-3
- Input 2 kV (Test Level 3 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- Depth 160 mm
- Installation distance top/bottom 50 mm / 50 mm
- Ambient temperature (start-up type tested) -40 °C
- Installation height ≤ 4000 m (> 2000 m, observe derating)
- Nominal output current (IN) 10 A
- Control deviation < 0.55 % (Static load change 10Â % ... 90Â %)
- Insulation voltage input/output 4 kV AC (type test)
- Conductor cross section solid max. 1.5 mm²
- Charge characteristic curve IU0U
- Standard - safety for equipment for measurement, control, and laboratory use IECÂ 61010-1
- Noise emission ENÂ 61000-6-3 (Class B)
- Electrostatic discharge EN 61000-4-2
- Comments Criterion A
- Output 1 kV (Test Level 1 - symmetrical)
- Voltage 10 V (Test Level 3)
- ECLASS 10.0.1 27040705
- ETIM 6.0 EC000382
- Connection in parallel yes, with diode module uncoupled
- Net weight 1.34 kg
- Mounting position horizontal DIN rail NS 35, EN 60715
- Conductor cross section flexible min. 0.2 mm²
- EMC requirements for noise emission ENÂ 61000-6-3
- Standard - Safe isolation DINÂ VDEÂ 0100-410
- UL approvals UL Listed ULÂ 61010
- DNVÂ GL conducted interference Class B
- Frequency range 0.15 MHz ... 80 MHz
- Signal 1 kV (Test Level 2 - asymmetrical)
- I/O/S asymmetrical
- REACh SVHC Lead 7439-92-1
- ETIM 7.0 EC000382
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?