2907081 Phoenix Contact UPS (DC)
Part#:2907081
Manufacturer:Phoenix Contact
Category:UPS (DC)
Product Lifecycle:Active
Get a quick Quote!
QUINT UPS with IQ Technology, RJ45 communication interfaces (EtherCAT®), for DIN rail mounting, input: 24 V DC, output: 24 V DC / 40 A, charging current: 5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers UPS (DC) that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2907081 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight 0.7 kg
- UPS connection in parallel no
- Depth 125 mm
- Installation distance right/left (active, passive) 0 mm / 0 mm (POut ≤50 %)
- Installation distance top/bottom (passive) 40 mm / 20 mm (POut ≥50% )
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- UPS connection in series no
- Height with alternative assembly 130 mm
- Degree of protection IP20
- Climatic class 3K3 (ENÂ 60721)
- Inrush current ≤ 9 A (≤ 4 ms)
- Fixed backup threshold 22 VÂ DC
- Width 47 mm
- Depth with alternative assembly 49 mm
- Installation distance top/bottom (active) 50 mm / 50 mm (POut ≥50% )
- Ambient temperature (start-up type tested) -40 °C
- Installation height ≤ 4000 m
- Degree of pollution 2
- Voltage drop, input/output 0.5 VÂ DC
- No-load proof yes
- Efficiency typ. 97 %
- Nominal capacity (without additional charger) 7 Ah ... 100 Ah
- Battery technology VRLA, VRLA-WTR, LI-ION
- Deep discharge protection 19.2 VÂ DC
- Conductor cross section solid max. 2.5 mm²
- Stripping length 6.5 mm
- Tightening torque max 0.6 Nm
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electromagnetic HF field ENÂ 61000-4-3
- Comments Criterion A
- Surge voltage load (surge) ENÂ 61000-4-5
- Frequency 0 Hz
- ECLASS 10.0.1 27040705
- UNSPSC 13.2 39121004
- Height 130 mm
- Installation distance right/left (active) 5 mm / 5 mm (POut ≥50% )
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Input voltage 24 VÂ DC
- Reverse polarity protection yes
- Switch-over time 0 ms
- Dynamic Boost (IDyn.Boost) 60 A (5 s)
- End-of-charge voltage (temperature-compensated) 25 VÂ DC ... 32 VÂ DC
- Charging current (configurable) 5 A
- Temperature compensation (configurable) 42 mV/K
- Identification IECÂ 61010-1
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Input voltage range 18 VÂ DC ... 30 VÂ DC
- Switch-on time max. 3 s
- Energy storage device connection in parallel Yes, 5 (observe line protection)
- Output voltage range 19 VÂ DC ... 32 VÂ DC
- Static Boost (IStat.Boost) 45 A
- Max. capacity 135 Ah
- IQ-Technology yes
- Connection method Screw connection
- Conductor cross section flexible max. 2.5 mm²
- ECLASS 5.1 27242213
- Electric strength, max. 35 VÂ DC
- Short-circuit-proof yes
- Energy storage device connection in series no
- Selective Fuse Breaking (ISFB) 215 A (15 ms)
- Charge characteristic curve IU0U
- MTBF (IEC 61709, SN 29500) > 1151000 h (25 °C)
- Temperature sensor yes
- Conductor cross section AWG max. 12
- Installation distance top/bottom (active, passive) 40 mm / 20 mm (POut ≤50 %)
- Buffer time 45 min. (38 Ah)
- Conductor cross section flexible min. 0.2 mm²
- Standard designation Safety extra-low voltage
- Designation CB scheme
- UNSPSC 21.0 39121011
- Width with alternative assembly 123 mm
- Charging time 202.5 h
- Conductor cross section solid min. 0.2 mm²
- Single conductor/terminal point, stranded, with ferrule, min. 0.5 mm²
- EMC requirements for noise immunity ENÂ 61000-6-1
- EMC requirements for noise emission ENÂ 61000-6-3
- Frequency range 50 Hz ... 60 Hz
- Output 1 kV (Test Level 3 - symmetrical)
- I/O/S asymmetrical
- Additional text DC, 60 s
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Internal input fuse no
- Life expectancy (electrolytic capacitors) 126720 h
- Contact discharge 8 kV (Test Level 4)
- Input 1 kV (Test Level 3 - symmetrical)
- Signal 1 kV (Test Level 2 - asymmetrical)
- ECLASS 11.0 27040705
- ETIM 7.0 EC000382
- Installation distance right/left (passive) 0 mm / 0 mm (POut ≥50% )
- Single conductor/terminal point, stranded, with ferrule, max. 16 mm²
- Standards/regulations IECÂ 61010-1 (SELV)
- Discharge in air 15 kV (Test Level 4)
- Power frequency magnetic field EN 61000-4-8
- Voltage 10 V (Test Level 3)
- UNSPSC 19.0 39121011
- End-of-charge voltage 32 VÂ DC
- Environmental protection directive RoHS Directive 2011/65/EU
- Conductor cross section AWG min. 30
- Tightening torque, min 0.5 Nm
- Electrostatic discharge EN 61000-4-2
- Fast transients (burst) ENÂ 61000-4-4
- Conducted interference ENÂ 61000-4-6
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 9.0 27040705
- UNSPSC 20.0 39121011
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Test field strength 300 A/m
- REACh SVHC Lead 7439-92-1
- ETIM 6.0 EC000382
- UNSPSC 18.0 39121011
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?