QUINT UPS with IQ Technology, RJ45 communication interfaces (PROFINET), for DIN rail mounting, input: 24 V DC, output: 24 V DC / 40 A, charging current: 5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers UPS (DC) that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2907079 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight 0.7 kg
- Additional text DC, 60 s
- Width 47 mm
- Width with alternative assembly 123 mm
- Installation distance right/left (active, passive) 0 mm / 0 mm (POut ≤50 %)
- Installation distance top/bottom (active) 50 mm / 50 mm (POut ≥50% )
- Climatic class 3K3 (ENÂ 60721)
- Inrush current ≤ 9 A (≤ 4 ms)
- Input voltage range 18 VÂ DC ... 30 VÂ DC
- UPS connection in series no
- Output voltage range 19 VÂ DC ... 32 VÂ DC
- End-of-charge voltage (temperature-compensated) 25 VÂ DC ... 32 VÂ DC
- Nominal capacity (without additional charger) 7 Ah ... 100 Ah
- Buffer time 45 min. (38 Ah)
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG min. 30
- Standards/regulations IECÂ 61010-1 (SELV)
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Contact discharge 8 kV (Test Level 4)
- Test field strength 300 A/m
- I/O/S asymmetrical
- Designation CB scheme
- Depth 125 mm
- Installation distance top/bottom (passive) 40 mm / 20 mm (POut ≥50% )
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Internal input fuse no
- Switch-on time max. 3 s
- No-load proof yes
- Energy storage device connection in parallel Yes, 5 (observe line protection)
- End-of-charge voltage 32 VÂ DC
- Charging current (configurable) 5 A
- Charge characteristic curve IU0U
- Conductor cross section solid max. 2.5 mm²
- Single conductor/terminal point, stranded, with ferrule, min. 0.5 mm²
- Conductor cross section AWG max. 12
- EMC requirements for noise emission ENÂ 61000-6-3
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electromagnetic HF field ENÂ 61000-4-3
- Fast transients (burst) ENÂ 61000-4-4
- Conducted interference ENÂ 61000-4-6
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- UNSPSC 13.2 39121004
- ETIM 7.0 EC000382
- UNSPSC 18.0 39121011
- Height 130 mm
- Depth with alternative assembly 49 mm
- Installation distance top/bottom (active, passive) 40 mm / 20 mm (POut ≤50 %)
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Installation height ≤ 4000 m
- Reverse polarity protection yes
- Switch-over time 0 ms
- Efficiency typ. 97 %
- Static Boost (IStat.Boost) 45 A
- Max. capacity 135 Ah
- Temperature sensor yes
- Environmental protection directive RoHS Directive 2011/65/EU
- Conductor cross section flexible min. 0.2 mm²
- Tightening torque max 0.6 Nm
- Electrostatic discharge EN 61000-4-2
- Frequency range 50 Hz ... 60 Hz
- Input 1 kV (Test Level 3 - symmetrical)
- Output 1 kV (Test Level 3 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- ECLASS 10.0.1 27040705
- UNSPSC 21.0 39121011
- Height with alternative assembly 130 mm
- Installation distance right/left (active) 5 mm / 5 mm (POut ≥50% )
- Degree of protection IP20
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Input voltage 24 VÂ DC
- Short-circuit-proof yes
- UPS connection in parallel no
- Dynamic Boost (IDyn.Boost) 60 A (5 s)
- Battery technology VRLA, VRLA-WTR, LI-ION
- Charging time 202.5 h
- MTBF (IEC 61709, SN 29500) > 1151000 h (25 °C)
- Deep discharge protection 19.2 VÂ DC
- Connection method Screw connection
- Single conductor/terminal point, stranded, with ferrule, max. 16 mm²
- EMC requirements for noise immunity ENÂ 61000-6-1
- Standard designation Safety extra-low voltage
- Comments Criterion A
- Signal 1 kV (Test Level 2 - asymmetrical)
- Power frequency magnetic field EN 61000-4-8
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27040705
- ECLASS 9.0 27040705
- Installation distance right/left (passive) 0 mm / 0 mm (POut ≥50% )
- Ambient temperature (start-up type tested) -40 °C
- Degree of pollution 2
- Electric strength, max. 35 VÂ DC
- Fixed backup threshold 22 VÂ DC
- Voltage drop, input/output 0.5 VÂ DC
- Energy storage device connection in series no
- Selective Fuse Breaking (ISFB) 215 A (15 ms)
- Temperature compensation (configurable) 42 mV/K
- IQ-Technology yes
- Life expectancy (electrolytic capacitors) 126720 h
- Conductor cross section flexible max. 2.5 mm²
- Stripping length 6.5 mm
- Tightening torque, min 0.5 Nm
- Identification IECÂ 61010-1
- Discharge in air 15 kV (Test Level 4)
- Surge voltage load (surge) ENÂ 61000-4-5
- Voltage 10 V (Test Level 3)
- Frequency 0 Hz
- ETIM 6.0 EC000382
- UNSPSC 20.0 39121011
- ECLASS 5.1 27242213
- UNSPSC 19.0 39121011
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?