2907072 Phoenix Contact UPS (DC)
Part#:2907072
Manufacturer:Phoenix Contact
Category:UPS (DC)
Product Lifecycle:Active
Get a quick Quote!
QUINT UPS with IQ Technology, USB communication interface (Modbus/RTU), for DIN rail mounting, input: 24 V DC, output: 24 V DC / 20 A, charging current: 5 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers UPS (DC) that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2907072 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight 0.6 kg
- Height 130 mm
- Installation distance right/left (active, passive) 0 mm / 0 mm (POut ≤50 %)
- Installation distance top/bottom (active) 50 mm / 50 mm (POut ≥50% )
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Input voltage 24 VÂ DC
- Electric strength, max. 35 VÂ DC
- Switch-over time 0 ms
- Energy storage device connection in parallel Yes, 5 (observe line protection)
- Efficiency typ. 98 %
- Max. capacity 135 Ah
- Depth 125 mm
- Installation distance right/left (passive) 0 mm / 0 mm (POut ≥50% )
- Degree of protection IP20
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Input voltage range 18 VÂ DC ... 30 VÂ DC
- Switch-on time max. 3 s
- Voltage drop, input/output 0.4 VÂ DC
- UPS connection in series no
- Buffer time 19 min. (12 Ah)
- MTBF (IEC 61709, SN 29500) > 1405000 h (25 °C)
- Conductor cross section solid min. 0.2 mm²
- Stripping length 6.5 mm
- Tightening torque max 0.6 Nm
- Designation CB scheme
- Width with alternative assembly 123 mm
- Installation distance top/bottom (passive) 40 mm / 20 mm (POut ≥50% )
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Degree of pollution 2
- Internal input fuse no
- Inrush current ≤ 8 A (≤ 4 ms)
- Static Boost (IStat.Boost) 25 A
- Battery technology VRLA, VRLA-WTR, LI-ION
- Charging current (configurable) 5 A
- Charging time 202.5 h
- Environmental protection directive RoHS Directive 2011/65/EU
- Conductor cross section flexible max. 2.5 mm²
- Single conductor/terminal point, stranded, with ferrule, min. 0.2 mm²
- Tightening torque, min 0.5 Nm
- Standard designation Safety extra-low voltage
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Electromagnetic HF field ENÂ 61000-4-3
- Fast transients (burst) ENÂ 61000-4-4
- Conducted interference ENÂ 61000-4-6
- Voltage 10 V (Test Level 3)
- Additional text DC, 60 s
- REACh SVHC Lead 7439-92-1
- ECLASS 11.0 27040705
- UNSPSC 13.2 39121004
- Width 40 mm
- Depth with alternative assembly 42 mm
- Installation distance top/bottom (active, passive) 40 mm / 20 mm (POut ≤50 %)
- Ambient temperature (start-up type tested) -40 °C
- Climatic class 3K3 (ENÂ 60721)
- Reverse polarity protection yes
- No-load proof yes
- UPS connection in parallel no
- Dynamic Boost (IDyn.Boost) 30 A (5 s)
- Nominal capacity (without additional charger) 3 Ah ... 100 Ah
- Charge characteristic curve IU0U
- Temperature sensor yes
- Connection method Screw connection
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section AWG min. 30
- Conductor cross section AWG max. 12
- Identification IECÂ 61010-1
- Standards/regulations IECÂ 61010-1 (SELV)
- Electrostatic discharge EN 61000-4-2
- Frequency range 50 Hz ... 60 Hz
- Comments Criterion A
- Output 1 kV (Test Level 3 - symmetrical)
- Criterion A Normal operating behavior within the specified limits.
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 9.0 27040705
- UNSPSC 20.0 39121011
- Height with alternative assembly 130 mm
- Installation distance right/left (active) 5 mm / 5 mm (POut ≥50% )
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Installation height ≤ 4000 m
- Fixed backup threshold 22 VÂ DC
- Short-circuit-proof yes
- Output voltage range 19 VÂ DC ... 32 VÂ DC
- Selective Fuse Breaking (ISFB) 120 A (15 ms)
- End-of-charge voltage (temperature-compensated) 25 VÂ DC ... 32 VÂ DC
- Temperature compensation (configurable) 42 mV/K
- IQ-Technology yes
- Life expectancy (electrolytic capacitors) 192072 h
- Conductor cross section flexible min. 0.2 mm²
- Discharge in air 15 kV (Test Level 4)
- Single conductor/terminal point, stranded, with ferrule, max. 4 mm²
- EMC requirements for noise emission ENÂ 61000-6-3
- EMC requirements for noise immunity ENÂ 61000-6-1
- Contact discharge 8 kV (Test Level 4)
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Input 1 kV (Test Level 3 - symmetrical)
- I/O/S asymmetrical
- Power frequency magnetic field EN 61000-4-8
- ECLASS 5.1 27242213
- ETIM 6.0 EC000382
- UNSPSC 19.0 39121011
- Test field strength 300 A/m
- Signal 1 kV (Test Level 2 - asymmetrical)
- Surge voltage load (surge) ENÂ 61000-4-5
- Frequency 0 Hz
- ECLASS 10.0.1 27040705
- ETIM 7.0 EC000382
- UNSPSC 18.0 39121011
- UNSPSC 21.0 39121011
- Deep discharge protection 19.2 VÂ DC
- Energy storage device connection in series no
- End-of-charge voltage 32 VÂ DC
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?