2907070 Phoenix Contact UPS (DC)
Part#:2907070
Manufacturer:Phoenix Contact
Category:UPS (DC)
Product Lifecycle:Active
Get a quick Quote!
QUINT UPS with IQ Technology, RJ45 communication interfaces (EtherCAT®), for DIN rail mounting, input: 24 V DC, output: 24 V DC / 10 A, charging current: 3 A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers UPS (DC) that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2907070 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight 0.5 kg
- UNSPSC 20.0 39121011
- Selective Fuse Breaking (ISFB) 60 A (15 ms)
- Nominal capacity (without additional charger) 1.2 Ah ... 60 Ah
- Temperature compensation (configurable) 42 mV/K
- Buffer time 25 min. (7.2 Ah)
- Deep discharge protection 19.2 VÂ DC
- Life expectancy (electrolytic capacitors) 137895 h
- Conductor cross section solid max. 2.5 mm²
- Conductor cross section flexible min. 0.2 mm²
- Conductor cross section AWG min. 30
- Stripping length 6.5 mm
- Designation CB scheme
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Electromagnetic HF field ENÂ 61000-4-3
- Comments Criterion A
- Conducted interference ENÂ 61000-4-6
- Additional text DC, 60 s
- REACh SVHC Lead 7439-92-1
- ECLASS 9.0 27040705
- UNSPSC 18.0 39121011
- UNSPSC 21.0 39121011
- Static Boost (IStat.Boost) 12.5 A
- Max. capacity 80 Ah
- End-of-charge voltage (temperature-compensated) 25 VÂ DC ... 32 VÂ DC
- Charging current (configurable) 3 A
- Temperature sensor yes
- Environmental protection directive RoHS Directive 2011/65/EU
- MTBF (IEC 61709, SN 29500) > 1189000 h (25 °C)
- Connection method Screw connection
- Conductor cross section flexible max. 2.5 mm²
- Single conductor/terminal point, stranded, with ferrule, max. 2.5 mm²
- Tightening torque max 0.6 Nm
- EMC requirements for noise emission ENÂ 61000-6-3
- EMC requirements for noise immunity ENÂ 61000-6-1
- Discharge in air 15 kV (Test Level 4)
- Input 1 kV (Test Level 3 - symmetrical)
- Surge voltage load (surge) ENÂ 61000-4-5
- I/O/S asymmetrical
- ECLASS 10.0.1 27040705
- ETIM 6.0 EC000382
- ETIM 7.0 EC000382
- Standards/regulations IECÂ 61010-1 (SELV)
- Electrostatic discharge EN 61000-4-2
- Frequency range 50 Hz ... 60 Hz
- Fast transients (burst) ENÂ 61000-4-4
- Output 1 kV (Test Level 3 - symmetrical)
- Voltage 10 V (Test Level 3)
- Criterion A Normal operating behavior within the specified limits.
- Frequency 0 Hz
- ECLASS 5.1 27242213
- UNSPSC 19.0 39121011
- Dynamic Boost (IDyn.Boost) 20 A (5 s)
- End-of-charge voltage 32 VÂ DC
- Charging time 120 h
- Charge characteristic curve IU0U
- IQ-Technology yes
- Conductor cross section solid min. 0.2 mm²
- Single conductor/terminal point, stranded, with ferrule, min. 0.2 mm²
- Conductor cross section AWG max. 12
- Tightening torque, min 0.5 Nm
- Standard designation Safety extra-low voltage
- Identification IECÂ 61010-1
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Test field strength 300 A/m
- Signal 1 kV (Test Level 2 - asymmetrical)
- Power frequency magnetic field EN 61000-4-8
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ECLASS 11.0 27040705
- UNSPSC 13.2 39121004
- Energy storage device connection in series no
- Battery technology VRLA, VRLA-WTR, LI-ION
- Height with alternative assembly 130 mm
- Installation distance right/left (passive) 0 mm / 0 mm (POut ≥50% )
- Degree of protection IP20
- Ambient temperature (start-up type tested) -40 °C
- Degree of pollution 2
- Reverse polarity protection yes
- Switch-on time max. 3 s
- No-load proof yes
- Energy storage device connection in parallel Yes, 5 (observe line protection)
- Height 130 mm
- Depth with alternative assembly 37 mm
- Installation distance right/left (active) 5 mm / 5 mm (POut ≥50% )
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Climatic class 3K3 (ENÂ 60721)
- Internal input fuse no
- Fixed backup threshold 22 VÂ DC
- Voltage drop, input/output 0.4 VÂ DC
- UPS connection in parallel no
- Output voltage range 19 VÂ DC ... 32 VÂ DC
- Width with alternative assembly 123 mm
- Installation distance right/left (active, passive) 0 mm / 0 mm (POut ≤50 %)
- Installation distance top/bottom (active, passive) 40 mm / 20 mm (POut ≤50 %)
- Installation distance top/bottom (active) 50 mm / 50 mm (POut ≥50% )
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Installation height ≤ 4000 m
- Electric strength, max. 35 VÂ DC
- Short-circuit-proof yes
- UPS connection in series no
- Width 35 mm
- Depth 125 mm
- Installation distance top/bottom (passive) 40 mm / 20 mm (POut ≥50% )
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Input voltage 24 VÂ DC
- Input voltage range 18 VÂ DC ... 30 VÂ DC
- Inrush current ≤ 7 A (≤ 4 ms)
- Switch-over time 0 ms
- Efficiency typ. 97 %
- Contact discharge 8 kV (Test Level 4)
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?