QUINT UPS with IQ Technology, for DIN rail mounting, input: 24Â VÂ DC, output: 24Â VÂ DCÂ /Â 5Â A, charging current: 1.5Â A
About the manufacturer: Phoenix Contact is one of the manufacturers that offers UPS (DC) that you can order at Power Resources International site. Phoenix Contact manufactures industrial electrical and electronic technology products that offer power, protection, connectivity, and automation for systems and equipment.
Check out the 2906990 Phoenix Contact price in the box on the right side or send a quick quote.
Product Details
- Weight 0.5 kg
- Depth 125 mm
- Installation distance right/left (passive) 0 mm / 0 mm (POut ≥50% )
- Installation distance right/left (active) 5 mm / 5 mm (POut ≥50% )
- Installation distance top/bottom (passive) 40 mm / 20 mm (POut ≥50% )
- Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
- Reverse polarity protection yes
- Internal input fuse no
- Switch-over time 0 ms
- Energy storage device connection in series no
- Dynamic Boost (IDyn.Boost) 10 A (5 s)
- End-of-charge voltage (temperature-compensated) 25 VÂ DC ... 32 VÂ DC
- Temperature compensation (configurable) 42 mV/K
- Charge characteristic curve IU0U
- Conductor cross section solid min. 0.2 mm²
- Conductor cross section AWG max. 12
- EMC requirements for noise immunity ENÂ 61000-6-1
- Standards/regulations IECÂ 61010-1 (SELV)
- Output 1 kV (Test Level 3 - symmetrical)
- Depth with alternative assembly 37 mm
- Installation distance top/bottom (active) 50 mm / 50 mm (POut ≥50% )
- Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
- Installation height ≤ 4000 m
- Fixed backup threshold 22 VÂ DC
- Efficiency typ. 98 %
- Output voltage range 19 VÂ DC ... 28 VÂ DC (UOUT = UBAT - 0.3Â VÂ DC)
- Max. capacity 40 Ah
- Temperature sensor yes
- Life expectancy (electrolytic capacitors) 224011 h
- Single conductor/terminal point, stranded, with ferrule, min. 0.2 mm²
- Conductor cross section AWG min. 30
- Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
- Test field strength 300 A/m
- Frequency range 50 Hz ... 60 Hz
- Discharge in air 15 kV (Test Level 4)
- Frequency 0 Hz
- Width 35 mm
- Installation distance right/left (active, passive) 0 mm / 0 mm (POut ≤50 %)
- Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
- Input voltage 24 VÂ DC
- Electric strength, max. 35 VÂ DC (Protected against polarity reversal)
- Voltage drop, input/output 0.3 VÂ DC
- Short-circuit-proof yes
- Width with alternative assembly 123 mm
- Installation distance top/bottom (active, passive) 40 mm / 20 mm (POut ≤50 %)
- Degree of protection IP20
- Climatic class 3K3 (ENÂ 60721)
- Ambient temperature (storage/transport) -40 °C ... 85 °C
- Input voltage range 18 VÂ DC ... 30 VÂ DC
- Height 130 mm
- Height with alternative assembly 130 mm
- Inrush current ≤ 7 A (≤ 4 ms)
- Input 1 kV (Test Level 3 - symmetrical)
- I/O/S asymmetrical
- ECLASS 10.0.1 27040705
- ECLASS 5.1 27242213
- UNSPSC 18.0 39121011
- Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
- ETIM 6.0 EC000382
- UNSPSC 13.2 39121004
- UPS connection in series no
- Energy storage device connection in parallel Yes, 5 (observe line protection)
- Nominal capacity (without additional charger) 0.8 Ah ... 40 Ah
- Conductor cross section solid max. 2.5 mm²
- Tightening torque max 0.6 Nm
- Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
- Conducted interference ENÂ 61000-4-6
- Voltage 10 V (Test Level 3)
- Power frequency magnetic field EN 61000-4-8
- ETIM 7.0 EC000382
- UNSPSC 20.0 39121011
- Degree of pollution 2
- UPS connection in parallel no
- Charging current (configurable) max. 1.5 A
- IQ-Technology yes
- Connection method Screw connection
- Conductor cross section flexible min. 0.2 mm²
- Stripping length 6.5 mm
- EMC requirements for noise emission ENÂ 61000-6-3
- Identification IECÂ 61010-1
- Electrostatic discharge EN 61000-4-2
- Static Boost (IStat.Boost) 6.25 A
- Charging time 150 min. (3.4 Ah)
- Conductor cross section flexible max. 2.5 mm²
- UNSPSC 19.0 39121011
- Ambient temperature (start-up type tested) -40 °C
- Switch-on time max. 3 s
- No-load proof yes
- Environmental protection directive RoHS Directive 2011/65/EU
- Single conductor/terminal point, stranded, with ferrule, max. 2.5 mm²
- Designation CB scheme
- Electromagnetic HF field ENÂ 61000-4-3
- Surge voltage load (surge) ENÂ 61000-4-5
- Signal 1 kV (Test Level 2 - asymmetrical)
- ECLASS 11.0 27040705
- ECLASS 9.0 27040705
- Battery technology VRLA, VRLA-WTR, LI-ION
- Selective Fuse Breaking (ISFB) 30 A (15 ms)
- Buffer time 25 min. (3.4 Ah)
- MTBF (IEC 61709, SN 29500) > 2065000 h (25 °C)
- Tightening torque, min 0.5 Nm
- Standard designation Safety extra-low voltage
- Contact discharge 8 kV (Test Level 4)
- Additional text DC, 60 s
- REACh SVHC Lead 7439-92-1
- Comments Criterion A
- Fast transients (burst) ENÂ 61000-4-4
- Criterion A Normal operating behavior within the specified limits.
- UNSPSC 21.0 39121011
Product condition
New Factory Sealed
New Factory Sealed - New condition, never used, original OEM part with original packaging and factory seal.
Manufacturer warranty
Request a quote, and we will send you price and availability within minutes.
Select Qty:
Average response time: 11 minutes
Fast Shipping & Delivery
Secure Payment Processing
Warranty
Responsive Customer Support
Need more details?
Feel free to chat with us
What can I help you find today?